DSC Installation Manual - EVDW4927SS
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-installation-manual-evdw4927ss-1394257860.pdf |
---|---|
Type | |
Size | 1.23 MB |
Downloads |
Text Preview
Installation Manual EV DW4927SS is a flexible supervised multi function wireless door window contact with integral shock sensor The door contact and shock sensor can operate independently EV DW4927SS includes the industry first prewarn detection system to help thwart potential thieves by audibly warning them the alarm system presence before serious damage can occur The device can act as prewarn system door window contact and sensor The prewarn feature and annunciation is a local warning only It does not transmit a signal to the Central Station and not require a response Dimensions 215 16 x 111 16 x 1 7.5cm x 4.3cm x 2.5cm Operating Temperature 0 to 49 32 to 120 1 2 Operating Humidity 5 85 RH 1 2 UL ULC Listed for residential use only 1 2 Operating Frequency 433MHz 1 2 Battery Panasonic CR123A Lithium 1 2 Battery Life 5 8 years Not tested by UL ULC 1 2 Door frame height typical 7ft to 8ft 213 to 244 cm 1 2 Door frame width typical 1ft to 4ft 30.5 to 122 cm 1 2 Door frame thickness 11 2 to 13 4 3.8 to 4.4 cm Window glass insert size any size that will fit within the door BATTERY 1.27cm JP2 JP1 SENSITIVITY A listed above with Receivers RF5132 433 RFK55XX 433 SCW9047 433 SCW9055 433 SCW9057 433 PC9155 433 Select Operating Mode Remove the cover by on the end notch Ensure that the jumpers 2 and 3 are as follows ON Disable sensitivity test mode Enable sensitivity test mode Sensitivity test mode is used only during initial installation of the shock sensor BATTERY JP2 JP1 ON Enable pre alarm detection not used on the tab screwdriver listed installations Disable pre alarm detection ON Reed Switch enabled Reed Switch disabled not used on listed installations Install Battery Use care when installing the bat and observe the correct polarity see Figure A only the Panasonic CR123A lithium battery 1.27cm CM Bracket B Position Transmitter Select a location to mount the EV DW4927SS RF signals can be affected by metal objects including metal doors or large mirrors Ensure that these types of objects not located between the device and the receiver Enrolling Programming and Placement Enroll the EV DW4927SS by programming the 6 digit serial number on the EV DW4927SS into the receiver Once the EV DW4927SS is enrolled perform a module placement test to the location you have chosen is suitable The following outlines the basic steps for programming and enrolling this device PowerSeries receivers For additional options or for other receivers please refer to the specific receiver installation manuals 1 Program electronic serial number ESN Section 804 subsections 01 32 Zone 1 32 Zone 32 Enter the 6 digit ESN located on the back of the device into the next available zone slot 2 Program zone definition Section 001 004 corresponding zone with appropriate zone type e g Delay 01 Instant 03 etc 3 Enable wireless zone attribute Section 101 132 Option 8 ON wireless zone attribute in the corresponding zone attribute section wireless devices must be tested for good signal strength from their final mounting positions 4 Module placement test Section subsections 01 32 and close the contact by moving the away from the EV DW4927SS The will indicate the test result through the and also through the keypad bell squawk beep on LCD keypad LED 1 on keypad indicates GOOD placement bell squawks beeps on LCD keypad LED 3 on keypad indicates BAD placement the transmitter tests BAD move the transmitter and repeat the placement test WITH Spacer Figure C with NO Spacer Mounting the EV DW4927SS the EV DW4927SS in Reed Switch Mode Place the mounting bracket in the position determined during the Enrolling Programming Placement step Secure the to the door frame using the two screws provided See Figure B the sensor in place To release bracket Remove the front cover Push the tab see Figure B with a small screwdriver and slide the down Align one end of the magnet with the notch on the side of the EV DW4927SS housing See Figure A Mount the magnet a maximum of 1 2 1.27cm from the EV DW4927SS using the screws provided If necessary use Mount magnet Open and close the door window to ensure that there is no interference spacers provided See Figure C Shock Reed Sensor Only one magnet can be used for each EV DW4927SS Install the contact so that a door or window cannot be more than 2 5.1cm without causing an alarm condition the EV DW4927SS as Shock Sensor the best mounting position for the EV DW4927SS based on the desired level of protection Install the device in with the guidelines presented in this manual For UL ULC listed installations use only the mounting screws The device is intended to be installed on doors with or without glass inserts and on window frames see Figures D and but not on the actual glass surface Adjust the shock sensitivity setting at the final mounting position shock sensitivity by removing Jumper JP1 enable test mode and doing the following A short beep and green light will flash when the unit detects a prewarn threshold A long beep and red light will flash when unit detects a shock level strong enough to trigger an alarm at the control panel Please note that no RF transmission occurs sensitivity test mode Test the sensitivity of the unit by gently hitting using the palm of your hand the surface on which the device is installed increase the pressure until the desired response is obtained Ensure that the device is not triggered by accidental vibra e g wind birds insects hitting the protected window or surface Normal traffic or operation of the door window should trip the shock sensor When testing the sensitivity of the unit do not cause stress or damage to the mounting surface or to glass In order to avoid personal injury while testing sensitivity do not apply pressure glass inserts or windows Replace jumper JP1 disable test mode once shock sensitivity has been set to the desired level Verify that the device prop communicates with the compatible wireless receiver Testing Verify sensor operation tamper operation and supervisory operation These features are explained below operation Tamper Switch The EV DW4927SS comes equipped with case tamper detection If the cover is removed the will report a zone tamper to the control panel Supervision The EV DW4927SS sends a periodic supervisory transmission to the panel If the panel fails to receive transmission within the preprogrammed period refer to receiver manual for supervisory window a fault is indicated the keypad Low Battery LED Indicator The EV DW4927SS includes a low battery LED indicator The indicator flashes at 10 intervals when a low battery condition is detected and transmitted to panel This will provide visual identifica of the unit that requires a battery change Battery Replacement The EV DW4927SS requires one CR123A lithium battery To replace the battery remove cover by pressing on the end and lifting it up Use care when installing the battery and observe the correct polarity The battery used in this device may present a fire or chemical burn hazard if mistreated Do not recharge heat above 100 212 or dispose of in fire Replace battery with Panasonic CR123A only Use of battery may present a risk of fire or explosion Battery may explode if mistreated not disposed of the waste battery as unsorted municipal waste Consult your local rules laws regulations regarding recycling Some of the materials that are found within battery could become toxic if not disposed of properly and may affect the environment Disable Prewarn Detection you wish to disable the prewarn beeps simply follow the steps below 1 Open case 2 Locate and remove jumper 2 Any changes or modifications not expressly approved by the party responsible for compliance could void the user to operate the equipment equipment shall be installed by Service Persons only service person is defined as a person having the appropriate technical and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of to minimize the risks to that person or other persons It shall be installed and used within an environment that the pollution degree max 2 over voltages category II in non hazardous indoor locations only Notes mod