DSC Keypad Partitioning PC1616 1832 1864 V4 2
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-keypad-partitioning-pc1616-1832-1864-v4-2-4785190326.pdf |
---|---|
Type | |
Size | 597.88 KB |
Downloads |
Text Preview
Notes Keypad Partition Assignments PC1616 1832 1864 V4.2 SERIES PC1616 1832 1864 V4.2 connected to the POWER SERIES panel can be assigned one of nine ways a keypad can be to operate a partition from 1 to 8 or as a global keypad Global keypads will not display any except for a trouble condition if present until the keypad is temporarily assigned to either a from 1 to 8 A global keypad allows the user to operate eight partitions through the use of one keypad partition assignment is a two step process Partitions the Keypad to a Partition and Slot Supervision Sections 201 000 0 902 1 to 8 Enable Assignment Supervision Field 1 Partition 2 8 Enable 2 through 8 must be enabled before keypads assigned to a partition 2 8 will operate To enable 2 to 8 perform the following Installer Programming Partition 1 to 8 Enable 8 Installer Code 201 2 to turn ON option 2 3 to turn ON option 3 4 to turn ON option 4 5 to turn ON option 5 6 to turn ON option 6 7 to turn ON option 7 8 to turn ON option 8 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 Page 29 2 Keypad Assignment the Partition Assignment and Slot of each keypad To assign the keypad perform the following a two digit number The first number represents the partition assigned to the keypad Installer Programming Keypad Assignment Section Partition and Slot Section 8 Installer Code 000 0 data 0 data 1 data 2 data 3 data 4 data 5 data 6 data 7 data 8 Global Mode Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 second digit represents the supervisory slot data 1 to 8 supervisory slot 1 to 8 same procedure must be performed on each keypad Keypads must each be assigned to a specific slot for the keypads to be properly an PK5500Z keypad is connected to the panel it must be assigned to slot 8 for purposes In addition only one PK5500 Z can be assigned to Slot 8 If LCD changes are made using the DLS software the keypad assigned to slot 8 will the changes to all the other PK5500Z keypads on the system after the download is 2 Module Supervisory Reset all modules are automatically detected and supervised by the panel within the first minute after being a Module Supervisory trouble condition may occur after keypad slot assignments are changed all keypads have been assigned to a Partition and Slot perform the following to perform a Module Reset Installer Programming Module Supervision Reset Installer Programming 8 Installer Code 902 1 minute verify what modules are present perform the following keypad will display the modules present LED keypads will be limited to the number of modules it can display To determine which Installer Programming Module Supervision Display 8 Installer Code 903 represents which module refer to the Installation Manual Section 2.7 Page 30 Tips a keypad is assigned to partition 2 to 8 and the partition is not enabled the keypad will not To correct the issue press and hold the key for 3 seconds then press and hold 1 to assign the keypad to partition 1 Enter Installer Programming and enable partition 2 to Step 1 above To temporarily assign a global keypad to a partition press and hold the partition number for 3 For example press and hold 1 for partition 1 or 2 for partition 2 etc If no key is for 20 seconds the keypad will return to the global state A partition keypad can be temporarily assigned to another partition To do this press and hold the key for 3 seconds The keypad will beep three times Press and hold the partition number for 3 For example press and hold 1 for partition 1 or 2 for partition 2 etc If no key is for 20 seconds the keypad will return to the partition it was originally assigned to When accessing Partition 3 through 8 an PK5501 keypad or an PK5500 Z v3.0 keypad must be Test a zone assigned to Partition 2 and ensure it is displayed on a partition 2 keypad Page 31