DSC LC-103 123 PIMSK installation manual

File Preview
File Preview
Click below to download for free

File Data

Name dsc-lc-103-123-pimsk-installation-manual-6348752910.pdf
Type PDF
Size 1.01 MB
Downloads

Text Preview

Form A Form C Motion Sensor PIR Microwave with Pet Anti Mask de movimiento de tecnolog doble sensor PIR y con inmunidad a mascotas y funci de anti de mouvement bi technologie IRP avec immunit aux animaux domestiques et di Movimento a Doppia Tecnologia Infrarosso antimasque immunit agli animali e antimascheramento czujka ruchu pasywna podczerwie i mikrofala na obecno zwierz z 1 Knockout holes I Orificios troquelados I Trous de d I Fori ciechi I Otwory monta accessory bracket Installation Wall mount bracket ceiling available del soporte Escuadra de montaje en pared escuadra para disponible du support Support de montage mural support pour montage plafond disponible dello snodo Snodo per il montaggio a parete disponibile per il montaggio a soffitto uchwytu Uchwyt do monta na dost tak uchwyt monta na suficie 2 Detector Installation Instalaci del detector Installation du d Installazione del rilevatore Monta czujki 7111673 Rev J detector provides an analysis of environmental conditions through entire movement speed frequency spectrum allowing focus on and eliminating environmental factors of false alarms The analysis is embedded in the VLSI based electronics of the assuring high reliability and trouble free operation Unique detector protection from non desirable and any kind of masking beginning from the distance 0.8m and the LC 103 PIMSK LC 123 PIMSK is a combined technology PIR an alarm signal relay activation occurs only when signals from both PIR MW are present at the same time The effective detection is the range of which the patterns PIR MW are intersected The GAIN adjustment changes the MW signal intensity so that the effective will be scaled This Installation Manual shall be used in conjunction with Installation Manual of the Control Panel INSTALLATION mounting location a location most likely to intercept an intruder Our recommendation is a installation See detection pattern Fig 3 The quad element high sensor detects motion crossing the beam it is slightly less sensitive motion toward the detector The Following Locations Facing direct sunlight Facing areas that change temperature rapidly Areas where there are air ducts or airflows The LC 103 PIMSK LC 123 PIMSK perform better when with a constant and stable environment detector shall be installed and used within an environment that provides pollution degree max 2 and overvoltages category II NON HAZARDOUS indoor only The detector is designed to be installed by service only The anti mask detection output will open for a minimum of 30 seconds will close only if a signal is received from the PIR after the initial 30 second THE DETECTOR Remove the front cover by unscrewing the holding screw Fig 2 11 gently raise the front cover Fig 2 5 Remove the PC board by unscrewing the holding screw located on the 2 9 Break out the desired holes for proper installation Fig 1 2 for flat mount Fig 1 3 for corner mount Use 4 screws type 3x30mm The circular and rectangular indentations at the bottom base Fig 1 1 Fig are the knockout holes for wire entry Mount the detector base to the wall or corner For optional LC L1ST accessory bracket installation open hole Fig 1 6 for bracket screw and install Bracket wall adapter Fig 2 1 3 or Bracket adapter Fig 2 2 3 Reinstall the PC board by fully tightening the holding screw Connect wire to terminal block Fig 4 Replace the cover by inserting it back in the appropriate closing pins and in the holding screw back tamper is assembled Fig 1 6 there is no bracket option and the must be installed in flat mounting only INSTALLATION Block Connections See Fig 4 1 2 Marked T1 T2 TAMPER Connect these terminals to a normally closed protective zone in the control unit If the front cover of detector is opened an immediate alarm signal will be sent to the control 3 4 Marked NC C This is the alarm output relay of Anti detection 5 Marked NC This is the NC Normally Closed output of ALARM This contact is functional on LC 103 PIMSK and LC 123 PIMSK 6 Marked C This is the COMMON output of ALARM relay 7 Marked NO This is the NO Normally Open of ALARM relay contact is functional on LC 123 PIMSK only 8 Marked GND Connect to the negative Voltage output or of the control panel 9 Marked 12V Connect to a positive Voltage output of 9.6 source Use only a listed power limited source The detector shall be provided with minimum of 4 hours of standby power either a listed compatible control unit or power supply UP THE DETECTOR Dipswitch Fig 5 2 ENABLE DISABLE 1 Used for Setting Up LED ENABLE The RED LED will activate when the is in alarm condition Factory Settings Down LED DISABLE The LED are disabled The state of the switch does not affect the operation of the relay an intrusion is detected the alarm relay will switch into alarm condition 2 sec In AM alarm condition all 3 LED blink together regardless of the LED position MASK FUNCTION 2 Used for Setting Anti Mask function Up protection against masking the detector from 0.4m and Factory Settings Down protection against masking the detector from 0.8m and SENSITIVITY ADJUSTMENT 3 Used for Setting provides sensitivity control of PIR to the environment Up Pulse 1 High sensitivity for stable environments Setting Down Position Pulse Auto Low sensitivity for harsh For ULC Installations use this position IMMUNITY SETTING 4 Used for Settings 15kg 25kg 33lbs 55lbs Up Immunity to an animal up to 15 kg 33lbs Down OFF Immunity to an animal up to 25 kg 55lbs Factory Pet immunity feature has not been tested by UL Detector must be restart by temporary remove power before the new will take effect CALIBRATION Fig 5.1 and 5.4 potentiometer adjusts the detection Range of MW between Minimum Maximum factory set to Middle Position potentiometer adjusts the detection Range between Minimum and factory set to Middle Position The MW and PIR potentiometer may need to be adjusted to the positions in order to achieve maximum area of coverage as indicated Fig 3 SIZE REQUIREMENTS 22 AWG 0.5 mm or wires with a larger diameter Use the following table determine required wire gauge diameter and length of wire between the and the control panel detector proporciona un an de las condiciones ambientales a lo del espectro completo de velocidades de movimiento lo que le centrarse en intrusos y eliminar los factores ambientales t las falsas alarmas El an del espectro est integrado en la del detector basada en la tecnolog VLSI lo que asegura una fiabilidad y un funcionamiento sin fallos La funci especial de anti garantiza al detector la protecci frente a una no deseada y cualquier tipo de enmascaramiento que a una distancia de 0,8 m o m cercana que el LC 103PIMSK LC 123 PIMSK est construido sobe una combinada sensor pasivo infrarrojo y microondas la activaci del de la se de alarma se da s cuando se reciben se de ambos PIR y microondas al mismo tiempo El alca

Related Files