DSC LCD5501Z32-433-Installation Manual-v4-1-English

File Preview
File Preview
Click below to download for free

File Data

Name dsc-lcd5501z32-433-installation-manual-v4-1-english-1285497630.pdf
Type PDF
Size 1.01 MB
Downloads

Text Preview

WARNING Please refer to the System Installation Manual for on limitations regarding product use and function and on the limitations as to liability of the manufacturer Manual v1.3 or higher INT version 4.1 of Contents A B E O C O N E N S 1 Installation 2 Mounting 2 Wiring 2 Applying Power 3 the Keypad 3 2 Keypad Programming the Keypad 5 Key Options 5 Clock Options 5 Alarms Displayed While Armed Option 6 Fire Auxiliary Panic Key Options 6 Door Chime Options 6 3 Receiver Programming Program Devices Serial Numbers 8 Wireless Devices Using Zones 8 Program Wireless Keys 9 Wireless Keys 10 Programming Handheld Keypads 11 4 Other Programming Zones and Partitions 12 Receiver Supervision 12 Supervision of Wireless Zones 12 Signal Detection 13 Software Default 14 5 Testing Mounting the placement of WLS904 WLS904P WLS906 WLS907 devices 15 WLS909 Reception 16 6 Additional Notes Conditions 17 Batteries in Wireless Devices 17 7 Troubleshooting 8 Programming Worksheets A Guidelines for Locating Smoke Detectors Display System Number Pad Function Emergency Open SYSTEM WEEKLY to Instruction Manual for instructions IN USEXXNOT IN USE IN USE PC1565 v2.3 and higher Power608 v2.3 and higher PC5008 v2.3 and higher LCD5501Z32 433 keypad combines a standard PC5132 receiver with an keypad that presents system status using an LCD style display with fixed With the addition of the keypad the control panel will now support up to 32 The LCD5501Z32 433 is compatible with the following DSC security systems PC5010 all versions PC5015 all versions PC585 v2.3 and higher Control panels previous to version 2.3 support 8 wireless zones Only one LCD5501Z32 keypad can be connected per system If more keypads required please select other DSC compatible keypads for the system being installed and Features Maximum Current Draw 260mA with backlighting boost on Frequency 433.92 MHz Zones receiver can receive signals from up to 32 wireless zones Supervisory programmable supervisory window one to 24 hours Location can be wired up to 1000 ft 305 m from the main panel with 22 gauge wire the wiring used in this circuit connection shall be insulated with PVC TFE PTFE neoprene or polymide for longer wire runs thicker gauge wire must be used Compatibility The LCD5501Z32 433 can be connected to the following panels PC5015 PC5008 PC1565 PC585 Connects to control panel via 4 wire Keybus One keypad zone input Optional tamper version Five programmable function keys Ready green Armed red and Trouble yellow status lights Unpacking LCD5501Z32 433 package includes the following par LCD5501Z32 433 package includes the following par LCD5501Z32 433 package includes the following parts LCD5501Z32 433 package includes the following par LCD5501Z32 433 package includes the following par One LCD5501Z32 433 keypad One 5.6K Ohm resistor Four mounting screws One keypad inner door label One set of Fire Auxiliary and Panic key labels One LCD5501Z User Sheet One LCD5501Z32 433 Installation Manual Mounting should mount the keypad where it is accessible to designated points of and exit Once you have selected a dry and secure location perform the steps to mount the keypad Remove the keypad backplate by loosening the screw located at the base of Secure the keypad backplate to the wall in the desired location Use the unit provided Before attaching the keypad to its backplate complete the keypad wiring as in the next section Wiring Before beginning to wire the unit ensure that all power AC transformer and is disconnected from the control panel Connect the four Keybus wires from the control panel red black yellow and to the keypad terminals R B Y G Consult the diagram below You can connect a device such as a door contact to the terminal of the This eliminates the need to run wires back to the control panel the device To connect the zone run one wire from the device to the Z terminal the other wire from the device to the B black terminal For powered devices the red wire to the R positive terminal and the black wire to the B negative When using end of line supervision connect the zone according to one the configurations outlined in your system Installation Manual Applying Power all wiring is complete apply power to the control panel Connect the battery leads to the battery Connect the AC transformer more information on control panel power specifications see the control Installation Manual Do not connect the power until all wiring is complete Enrolling the Keypad all wiring is complete you will need to enter a 2 digit number that tells the the partition and slot assignment of the keypad your system has partitions you will also need to assign the keypad to a 1st digit slot assignment 2nd digit tells the panel which keypad slots are occupied panel can then generate a fault when a keypad supervisory signal is not There are eight available slots for keypads LCD5501Z32 433 keypads always assigned to slot 1 by default You will need to assign each keypad to own slot 1 to 8 The LCD5501Z32 433 enrolls as two modules 1 keypad section of the LCD5501Z32 433 receiver section of the LCD5501Z32 433 the following at each keypad installed on the system Enter Installer Programming by pressing Press 000 for Keypad Programming Press 0 for Partition and Slot Assignment Enter a two digit number to specify the partition and slot assignment If your system does not have partitions enter 1 for the first digit Code digit 0 for Global Keypad 1 for Partition 1 Keypad 2 for Partition 2 Keypa

Related Files