DSC Maxsys v3 Engineers Spec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-maxsys-v3-engineers-spec-0764153829.pdf |
---|---|
Type | |
Size | 618.87 KB |
Downloads |
Text Preview
Maxsys TM n t e g r at e d s Y S T E M S T E C H N O L O G Y Alarm System System Panel security control panel shall have a total capacity of 128 zones The base shall have a capacity of 16 hardwired zones and 112 addressable zones two addressable loops All zones shall be fully supervised and programmable panel shall be complete with integral power supply and supervised charger auxiliary power for powering security detection devices switched auxiliary power supply for 4 wire smoke detectors supervised digital alarm communicator supervised bell siren output two general purpose programmable outputs which can be programmed as purpose outputs or as the system addressable loops system shall be complete with a standard non shielded 4 conductor wire bus Combus for powering and communicating with remote system expansion modules and devices The Combus shall be of up to 4 legs with each leg up to 1,000ft 305m long Expansion panel shall be expandable to a maximum of 128 zones by adding standard 8 and 16 zone modules connected to the base panel via the Combus adding up to 112 addressable detection devices to one or both of the loops on the base panel and by adding up to 8 distributed receiver modules to the combus for up to 64 wireless zones The shall be capable of expansion using hardwired addressable and in any combination that suits the application Codes system shall support 1,500 user codes selectable as either 4 or 6 For access control user codes shall be assignable to 1 of 64 access User codes shall be assignable to one or multiple partitions system shall be programmable for up to 8 fully independent partitions partition shall have its own account code Keypads shall be assignable as keypads or global keypads Each zone in the system shall be to one or more partitions System Keypads system shall accommodate up to 16 hardwired LCD keypads which are from the base panel via the 4 wire communications bus LCD keypads have a display capacity of at least 32 alphanumeric characters with brightness and contrast Keys shall be backlit for low light ease of Keypads shall include individual Armed Ready and Trouble indicators keypad activated alarm keys and five programmable function keys shall be available with red bezels as required for fire systems Security Control control devices shall include up to 4 wireless keypads in addition to keypads and up to 16 wireless keys for remote arm disarm devices shall include up to 64 wireless detectors including panic each of which occupies one wireless zone Station Reporting system shall provide high speed 10 20 bps 1400 2300Hz handshake ID and SIA reporting formats and shall be capable of being to call up to 3 telephone numbers The system shall also allow to a pager The telephone numbers shall be programmable for dialing should the primary number fail The system shall be for split reporting so that alarms restorals openings closings miscellaneous events can be sent to different telephone numbers system shall report a separate account code for each partition and for system events The system shall be capable of reporting all trouble and system status information by combinations of all methods installed including digital communicator cellular long range radio Cellemetry Mobitex and DVACS Printer system shall include a serial output module for a hard copy printer installed along the Combus All system events alarms and restorals shall be and each event shall include the partition date and time Event Buffer system shall have a 3,000 event buffer All events shall be printable from system printer The 2,800 most recent events shall be viewable by keypad display All events shall be viewable by local or remote PC Supply Relay Output Modules system shall be capable of including up to 64 fully programmable output with Form C contacts rated 2A at 30VDC Relays shall be added in of 4 and may be located anywhere on the Combus Each module shall a supervised 350mA 24VDC battery charger and integral power supply provide up to 1.0A of auxiliary power at 12VDC to power direct connected or repower the Combus Power Outputs system shall be capable of including up to 144 low power outputs with output able to supply 50mA at 12VDC Outputs shall be added in of 16 and may be added anywhere on the Combus Annunciation system shall be capable of remote zone alarm and system status up to 144 points by adding 32 and 64 point annunciators on the Combus Annunciators shall be capable of being flush mounted annunciators shall provide point and graphic annunciation capability Control system shall support 16 dual reader access control modules for a total of readers Each access control module shall be complete with an integral supply and supervised battery charger and shall provide full standalone if communication with the base panel is lost Access control modules include non volatile memory to retain all schedules and programming even if AC and battery power are lost and shall be capable of being to the system anywhere on the Combus control modules shall accept proximity readers magnetic stripe readers 26 bit Wiegand readers Readers shall be capable of being located up 500 feet 152.4 m from the modules Each access module shall have the inputs and outputs per reader request to exit detector input arm pushbutton input arm pushbutton input door contact input strike output and outputs for reader LED and buzzer control shall allow users to arm or disarm the security system while or unlocking the doors from outside the protected space Users may use valid card to disarm the system automatically while unlocking the door to arm system in combination with the arm pushbutton while locking the door to postpone autoarm in combination with the autoarm pushbutton Access software shall be an integral component of the base panel and shall provide the following functions capacity for 1,500 cards access levels 99 seven day schedules with 4 intervals per schedule holiday for a two year period and individual door unlock schedules with Daylight Saving Time adjust for all schedules Access control shall be fully programmable through any system keypad either or remotely using any PC and the upload download software system shall be capable of premise telephone entry control of up to 32 doors shall have an entry interface at each door with a fast scrolling directory up to 1,500 names with 12 digit phone numbers access control transactions shall be recorded in the system event buffer Status Control system shall be capable of providing system status and control via any or remote DTMF tone telephone System status information shall be by voice The system shall include a word library and allow custom for zone labels system shall be complete with an automation control module capable of 32 X 10 automation devices by event and by schedule The system include 16 schedules to control automation devices Automation shall be via any keypad and local or remote DTMF tone telephone system shall provide for 99 date schedules with 4 intervals per schedule holiday schedules with 2 years of scheduling capacity 99 open close schedules 50 arm disarm schedules 50 smoke detector test and 16 automation schedules All schedules shall be programmable the LCD keypads and via downloading either locally or remotely Fault Detection system shall include an integral ground fault detector capable of detecting single ground fault on any extended conductor in the system zone in the system shall be supervised The base panel and any remote with its own AC input shall be supervised for AC loss Batteries for the panel and all remote panels shall be supervised for low power and be circuit protected Each addressable device and each wireless input device be supervised for the device presence The Combus shall be supervised low voltage and the presence of each enrolled module and keypad All alarm methods employed by the system shall be supervised Alarm Prevention system shall include the following false alarm prevention features audible delay arm disarm bell squawk audible exit fault urgency on entry