DSC maxsys4020 spec sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-maxsys4020-spec-sheet-9026514837.pdf |
---|---|
Type | |
Size | 636.33 KB |
Downloads |
Text Preview
Maxsys n t e g r at e d s Y S T E M S T E C H N O L O G Y TO 128 ZONE CONTROL PANEL PC4020 is a 16 zone panel which is expandable to 128 zones Expansion can accomplished over a 4 wire Combus using a variety of input output and modules The base panel includes two addressable loops which can up to 112 addressable input devices and the system can also be with a 64 zone wireless receiver which connects to the system via the Combus Addressable hardwired and wireless expansion can be used in any that suits the application MAXSYS is software ready to implement all the security access control and residential fire functions by simply adding conventional or devices access control modules and automation interface components Panel Features 16 programmable zones zones can be NC with no EOLR NO NC single EOLR or NC with double EOLR 30 programmable zone types 8 zone options 2 PGM outputs each with 2 application choices as standard PGM output 59 programmable options as addressable loop up to 112 addressable devices 1 supervised bell circuit 59 programmable options 1 unswitched auxiliary power supply 1 switched auxiliary power supply supervised digital alarm communicator with 4 formats 20bps 1400 2300Hz handshake Contact ID SIA with auto reporting codes 3 telephone numbers 32 digits each 3 event initiated pager formats supervised battery charger PC Link connector for local upload download 8 system partitions 9 account codes 1,000 user card codes 64 access levels user card codes assignable by partition 3,000 event buffer 2,800 viewable on keypad 59 programmable output options for bell zone PGM outputs relay outputs transistor outputs comprehensive scheduling 99 date schedules 16 automation schedules 99 open close suppression schedules 50 addressable smoke detector test schedules 50 arm disarm schedules 4 two year holiday schedules multiple communication capabilities built in digital dialer optional module for DVAC optional Long range radio communication optional cellular communications upload download capability full featured with separate phone number Expansion PC4020 is easily expanded by adding input output and functional onto the 4 wire communications bus Combus Combus up to four runs of 1,000feet 305m can be t tapped and supervised for low voltage and module communication up to 16 LCD keypads 32 character display complete system programming via keypads keypads can be or operation Ready Armed and Trouble indicators LCD4501 5 programmable function keys LCD 4501 27 function key options Trouble and Armed indicators LCD4500 piezo buzzer for audible feedback and trouble 4 keypad activated alarms Panic Emergency Fire Duress up to 128 hardwired zones using PC4108A PC4116 eight and zone expansion modules up to 64 wireless zones using the PC4164RS wireless receiver and wireless sensors and control devices up to 112 addressable zones using the main panel PGM outputs as loops and DSC addressable sensors Wireless and Addressable zones may be mixed on the system to the total system capacity of 128 zones up to 144 low current outputs using PC4216 modules 16 outputs module 9 modules per system up to 64 relay outputs using PC4204 quad relay power supply up to 16 modules system each PC4204 also provides up 1 amp of auxiliary power and can be used to repower the Combus point graphic annunciation using PC4632 PC4664 remote for system partition and zone annunciation up to 32 access controlled doors using up to 16 PC4820 reader access control modules with stand alone capability X 10 automation using the Escort PC4580 module controls up to two X 10 devices and provides voice assisted system status and from any touchtone telephone system printer or DVACS communicator using the PC4400 interface module backup alarm communication using Links1000 cellular communicator Links2150 or Links2450 long range radio transmitters of the features functions and expansion capabilities of the PC4020 panel are included in the PC4020CF versions Specifications bell output 12VDC 700mA max continuous up to 2A for 4 minutes using battery assist PTC over current protected self restoring AUX output 12VDC 500mA max SAUX output 12VDC 300mA max SAUX output is normally 12VDC and power is removed upon Typically used to reset 4 wire smoke detectors total for AUX output and SAUX output is 500mA max If the SAUX output is loaded to 200mA then only 300mA for the AUX output AUX and SAUX outputs protected by a common PTC over current which is self restoring PGM outputs as standard PGM outputs 12VDC 50mA max each outputs are normally unpowered and switch to 12VDC activation as addressable outputs 12VDC 170mA max each PGM outputs are individually programmable as addressable or as general purpose PGM outputs Combus 500mA max from the PC4020 main panel additional power is provided by PC4204 modules Maximum capacitance is 80nF which is typically 4,000feet 1,219m 22AWG wire Consult wire manufacturer for specifications of to be used total loading for the Bell output AUX SAUX PGM1 PGM2 the Combus must not exceed 900mA This limit may be exceeded bell output if extra current required is drawn from the battery battery charger up to 350mA to charge 12volt lead acid batteries to 14Ah capacity Battery charger is supervised for opens and is by PTC over current device which is self restoring input power 16VAC 40VA ground fault detection built in and enabled by connecting earth to EGND terminal on PC4020 main panel use for version only Specifications operating environment 32 to 122 0 to 50 90 RH non condensing PC4050C beige cabinet surface mount hinged door with screw closure provision for door keylock provision for door and wall tamper switches space for two 12volt 7Ah lead acid rechargeable batteries 14.8 H x 12.0 W x 4.9 D 37.6 x 30.5 x 12.5cm System Arrangement DETECTORS addressable loops per system T tapped or star using 2 conductor station wire PC4204 is added when additional power is required to power downstream from PC4204 up to 16 PC4204 per system leg up to 305m PC4020 conductor wire DETECTORS CONTROLS 1 2 Information security control panel which includes PC4020 main control module PC4050C beige cabinet installation manual user manual and programming worksheets module mounting hardware and 32 EOL resistors as PC4020 but with PC4050CAR attack resistant cabinet are not supplied with the main panel at least one keypad is per system Select from the following keypad types alphanumeric keypad without function keys as LCD4500 but with wall tamper switch alphanumeric keypad with 5 function keys as LCD4501 but with wall tamper switch LCD4500R TR LCD4521 21T LCD4501R TR identical the above but have red bezels for use with PC4020CF fire panels 2 Central Station Burglar Alarm Local Burglar Alarm Police Station Burglar Alarm Household Fire Warning Household Burglar Alarm At least one fire version keypad must used with Maxsys UL listed fire panels The Links1000 Cellular