DSC maxsys4204 4216 spec sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-maxsys4204-4216-spec-sheet-5430967218.pdf |
---|---|
Type | |
Size | 645.47 KB |
Downloads |
Text Preview
Maxsys n t e g r at e d s Y S T E M S T E C H N O L O G Y MODULES systems can be expanded to provide up to 64 high current output and 144 low power outputs to meet the needs of a wide variety of system applications and designs further enhance the capability of Maxsys to meet large system the PC4204 and PC4204CF have the additional capability of the Maxsys communications bus Combus to provide an supply of power on the Combus wherever and whenever is required to meet the needs of the system now and in the future Low Power Output Module Power Supply Relay Output Module PC4216 provides programmable low power outputs ideal for remote relays and LEDs such as those used in Maxsys PC4632 PC4664 annunciators each module provides 16 transistor switch outputs supplying to 50mA 12VDC each connect up to 9 modules per system for 144 outputs total each output programmable to activate for any of 59 options outputs assignable to schedules and partitions can be used to power switch graphic annunciator lights relays connection for external tamper supervised by system connect up to 1,000 305m from control panel via COMBUS operating environment 32 to 122 0 to 50 90 RH non condensing current draw from Combus plus power required outputs PC4204 is a dual purpose power supply output module providing relay outputs for controlling external devices and power to the Combus to provide additional power as required for devices which are powered off of the Combus includes 4 fully programmable high current relays with Form rated 2A 30VDC provides 1A 12VDC to power direct connected devices or repower Combus uses relay 1 when repowering Combus connect up to 16 modules per system for 64 relays total each relay programmable to activate for any of 59 options complete with supervised battery charger 12VDC 350mA charging for sealed lead acid rechargeable batteries fully supervised for low battery and aux supply and power loss connection for external tamper supervised by system connect up to 1,000 305m from control panel via COMBUS operating environment 32 to 122 0 to 50 90 RH non condensing current draw from Combus Power Supply Relay Output Panel System Arrangement PC4204CF is a packaged version of the PC4204 meeting the of UL864 for UL listed commercial fire systems Note the is not required in Canada Use the PC4204 in Canada in a panel enclosure the PC4204CF contains a standard PC4204 a 350mA battery charger and a 16VAC 40VA transformer with space for two 7Ah batteries and one PC4108A hardwired zone module to comply with UL requirements the rated capacity of the for repowering the Combus is reduced to 550mA Panel Module supplied Barrier IN Ah battery supplied Ah battery supplied 4 fully programmable high current Form relays with contacts at 2A 30VDC provides 550mA 12VDC to power direct connected devices or the Combus based on 24 hour standby with two 7Ah uses relay 1 when repowering Combus complete with supervised battery charger 12VDC 350mA charging for sealed lead acid rechargeable batteries connect up to 16 modules per system for 64 relays total each relay programmable to activate for any of 59 options fully supervised for low battery and aux supply and AC power loss connection for external tamper supervised by system connect up to 1,000 305m from control panel via COMBUS operating environment 32 to 122 0 to 50 90 RH non condensing current draw from Combus dimensions x 12 W x 4.5 D 30.5 x 30.5 x 11.5cm Control Units System CS A M SS WF Central Station Burglar Alarm Local Burglar Alarm Police Station Burglar Alarm Household Fire Warning Household Burglar Alarm PC4204 does not have UL864 listing fire installations use the PC4204CF does have UL864 listing Central Station Fire Alarm Central Monitoring Station Local Alarm Commercial Alarm Household Burglar Alarm Household Fire Warning Access Control repowers the Combus as to compensate for voltage drop SUPPLY OUTPUT 4 conductor unshielded station wire modules to COMBUS up to 305m from main control panel CURRENT the Combus to 16 PC4204 CF may be installed in the Combus wherever additional is required downstream of the PC4204 for additional modules and powered off of the Combus PC4204CF GND RED BLK YEL GRN COM NC 1 IN for this option Jumper J1 must be set for Relay Information 16 point low power output module power supply relay output module with 4 relay outputs power supply relay output module with 4 relay outputs fire installations requiring UL864 listing includes PC4052CR red cabinet 12 H x 12 W x 4.5 D x 30.5 x 11.5cm PC4204 module PT1016 transformer 16VAC 40VA space for two 7Ah 12volt lead acid batteries space for one PC4108A hardwire zone expansion is a registered trademark of Digital Security Controls Ltd and may not be reproduced without permission in Canada 2002.12 Digital Security Controls Ltd Canada ISO9001 registered company