DSC NEO HS2LCD Install Manual ENG-FR-ESP-PT V1 1 R001
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-neo-hs2lcd-install-manual-eng-fr-esp-pt-v1-1-r001-9462785031.pdf |
---|---|
Type | |
Size | 1.79 MB |
Downloads |
Text Preview
HS2LED HS2ICON P RF X HS2LCD RF P X V1.1 Instructions Instructions d de de instala English Fran Espa Portugu Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used Ce manuel contient des informations sur les restrictions concernant le fonctionnement et l du produit et des informations sur les restrictions en ce qui concerne la responsabilit du La totalit du manuel doit lu attentivement Ce manuel doit utlis en conjunction avec le Manuel d du Panneau de contr Consulte el Manual de instalaci del sistema para obtener informaci sobre las limitaciones del uso y funciones del producto asi como las limitaciones de la reponsabilidad del fabricante Estas instrucciones deber utilizarse conjuntamente con el Manual de instalaci del sistema del Panel de control con el que se vaya a utilizar este equipo Consulte o Manual de instala do sistema para obter informa acerca das limita relativas utiliza do produto e fun e informa acerca das limita relativas imputa de ao fabricante Estas instru devem ser utilizadas em conjunto com o Manual de instala do sistema do painel de controlo com o qual este equipamento se destina a ser utilizado HS2LED HS2ICN P RF x HS2LCD RF P x keypads are with the PowerSeries Neo HS2016 32 64 HS2014 4 HS2128 panels The RF keypads combine a wireless trans with the respective HS2 keypad not UL ULC listed Temperature range to 55 14 to 131 0 to 49 32 to 120 Humidity MAX 93 R H non condensing enclosure protection degree IP30 IK04 Voltage rating 13.8Vdc nominal power provided by the com control panel Connects to control panel Corbus via 4 wires configurable zone input or PGM output HS2LED HS2ICN P HS2LCD P HS2ICNRF P Current draw 55mA min 105mA max Wall mount tamper programmable function keys Ready Green LED Armed Red LED Trouble Yellow AC Green LED Dimensions L x W x D 168mm x 122mm x 20 mm Weight 260g Low temperature sensor 433 MHz HS2ICNRF4 HS2LCDRF4 MHz HS2ICNRF8 HS2LCDRF8 HS2ICNRF9 HS2LCDRF9 Up to 128 wireless zones not to be programmed as Fire type or 24h type Keypads contain no serviceable parts Only models operating in band 912 919MHz are UL ULC keypad package includes the following HS2ICN RF P LCD RF P keypad mounting screws end of line resistors inner door labels tamper switch Instructions keypad mounting screws end of line resistors inner door labels tamper switch Instructions Proximity prox tag MPT 1 Compatible Devices PG smoke detector PG smoke and heat detector PG CO detector PG PIR motion detector PG PIR camera motion PG curtain motion detector PG dual tech motion detector PG mirror motion detector PG outdoor motion detector PG glass break detector PG shock detector PG flood detector PG temperature detector temperature probe requires PG key PG key PG panic key PG 2 button key PG indoor siren PG outdoor siren PG repeater PG door window contact PG door window contact In this chart x in the model number represents the oper frequency of the device as follows 9 912 919 MHz 8 4 433MHz Only models operating in the band 912 919 MHz are or cUL listed where indicated Only UL approved are to be used with UL ULC listed systems the Keypad the keypad where it is accessible designated points of entry and exit a dry and secure location has been perform the following steps to the keypad Keypad the tip of a flat head screwdriver the slots at the bottom left and right the keypad pry open the faceplate This will it and allow access for mounting and Wire Keypad Secure keypad to wall using mounting holes Use all four provided unless mounting on a single gang box Use the anchors supplied if the unit is to be mounted on drywall If using the keypad tamper secure the tamper plate to the wall a screw For UL ULC listed commercial burglary installations the of the keypad tamper is mandatory Run wire through wiring slot or knockouts Connect Corbus and wiring to keypad Place tamper switch into tamper on backplate Place keypad into backplate ensuring the wire is pushed back the wall as much as possible Route the wire inside the ensuring high components are avoided Snap the front closed ensuring that there is no pressure to the keypad the wire below If any tension is found between the front keypad assembly the wiring open the keypad reroute the wire and close again these steps until the keypad is closed properly Before wiring the unit ensure that power AC transformer and bat is disconnected from the con panel Connect the four Corbus wires the control panel red black and green to the keypad ter Refer to the diagram programmed as an input a device such as a door contact may be to the terminal of keypad This eliminates the need to run wires back to the panel for the device To connect the zone run one wire the device to the terminal and the other wire from the to the B black terminal For powered devices run the red to the R positive terminal and the black wire to the B neg terminal When using end of line supervision connect the according to one of the configurations described in the Power Neo Reference manual For UL ULC installations the zone input is a supervised SEOL DEOL The supervision resistor is 5600 If no supervision is used there is a three foot maximum distance for the connected device Use only in conjunction with listed devices This initiating device connected to this input contact is to be used for medical or fire applications If the terminal is programmed as an output a small relay as DSC model RM 1 or RM 2 or buzzer or other DC oper device may be connected between the positive supply voltage the terminal max load is 50mA For UL ULC listed installations use UL ULC listed Power all wiring is complete and the equipment is secured to the structure with at least two screws apply power to the panel Connect the battery leads to the battery Connect the AC transformer more information on control panel power specifications see PowerSeries Neo Reference manual the Keypad Press 8 Installer Code Use the keys to nav through the menus or jump to a specific section by the section number consists of tog on and off options in each or by populating data Toggle options are or disabled by pressing corresponding number on the For example to enable options 1 and 4 press the and 4 keys All enabled are displayed see the following diagram To input data use the keys to select a character then the keypad button for the number letter Using the keys scroll to the next character and repeat procedure For information on entering HEX data refer to the Neo Reference manual Romanian Russian Bulgarian Latvian Lithuanian Ukrainian Slovak Serbian Estonian Slovenian German Swedish Norwegian Danish Hebrew Greek Turkish FFU Croatian Hungarian Programming 000 000 Enter the two digit number corresponding to the desired 2 Languages English Spanish Portuguese French Italian Dutch Polish Czech Finnish the Keypad ca