DSC NT9005-433 v1 0 - Programming Worksheet - English

File Preview
File Preview
Click below to download for free

File Data

Name dsc-nt9005-433-v1-0-programming-worksheet-english-8356140279.pdf
Type PDF
Size 760.85 KB
Downloads

Text Preview

NT9005 433AUS Programming Worksheets Function Key Assignment Valid entries are 00 22 Key 1 Assignment Key 2 Assignment Key 3 Assignment Key 4 Assignment Key 5 Assignment Keys Key not used Future Use Future Use Arm Arm No Entry Arm Chime On Off System Test Bypass Mode Trouble Display Alarm Memory User Programming User Functions Output 1 Output 2 Sensor Reset Future Use Quick Exit Activate Stay Away Zones Use Output 3 Use Output 4 Use First Keypad Option Code cid 1 denotes default cid 2 ON Local Clock Display Enabled Local Clock Displays AM PM OFF Local Clock Display Disabled Local Clock Displays 24 hr Time Open Zones Override Clock Display Open Zones do not Override Local Clock Alarms are not Displayed While Armed Alarms are Displayed While Armed Door Chime Enabled for Zone Openings Door Chime Disabled for Zone Openings Door Chime Enabled for Zone Closings Door Chime Disabled for Zone Closings Future Use Future Use OFF F Key Disabled A Key Disabled P Key Disabled Leading 0 Displayed in Clock Leading 0 not Displayed Priority Key Options ON F Key Enabled A Key Enabled P Key Enabled Future Use System Programming Definitions Zone Not Used 1 2 Stay Away Stay Away Future Use Future Use Future Use Burglary Holdup Gas Heat Medical Panic Emergency Sprinkler Water Freeze Momentary Keyswitch Arm Maintained Keyswitch Arm Non alarm zone Use Delay Future Use Future Use Future Use Future Use 24 hr Fire Wireless Supervisory Buzzer NOTE 22 and 23 should not be wireless zones When they go into supervisory trouble it will disarm the system 24 hr Fire Wireless Latching Tamper Zone 1 8 Definitions Default Default Zone 9 16 Definitions Default Default Zone 17 24 Definitions Default Default Zone 25 32 Definitions Default Default Delay 1 Delay 2 Delay Cut off 3 digits from 001 255 seconds 3 digits from 001 255 seconds 3 digits from 001 255 seconds 3 digits from 001 255 minutes System Times Installer Code Master Code Maintenance Code Output Options Burglary Output Future Use Future Use Future Use Status to Arm Buzzer Follow Mode Pulse Trouble Output with Trouble Options Event with Event options Start Pulse Operation Future Use Armed Status Armed Status Output 1 Output 2 Output 3 Output 4 Future Use Tamper zones keypad modules Future Use and Alarm Fire and Burglary Output Output Only one of Types 03 and 20 may be be used on a system PGM Output Programming PGM 1 2 NT9204 PGM Output Programming 1 2 11 12 13 14 Keypad Lockout Options of Invalid Codes Before Lockout valid entries 000 255 Duration in Minutes 000 255 In order to use PGM the corresponding zone in 030 must be to 00 First System Option Code ON Normally Closed Loops OFF End of Line Resistors Double End of Line Resistors Single End of Line Resistors Panel Shows All Troubles While Armed Panel Shows Only Fire Troubles While Armed Tampers Faults do not Show as Open Tampers Faults Show as Open Future Use Audible Exit Fault Enabled Audible Exit Fault Disabled Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past Shutdown Temporal Three Fire Signal Enabled Standard Pulse Fire Signal Second System Option Code ON OFF Arm Disarm Bell Squawk Enabled Arm Disarm Bell Squawk Disabled Bell Squawk During Auto arm No Bell Squawk During Auto arm Bell Squawk on Exit Delay Bell Squawk on Entry Delay Bell Squawk on Trouble No Bell Squawk on Exit Delay No Bell Squawk on Entry Delay No Bell Squawk on Trouble Audible Exit with Urgency Away Silent Exit Delay Away Exit Delay Termination Enabled Exit Delay Termination Disabled Fire Bell is Continuous Fire Bell Follows Bell Cut off Third System Option Code ON F Key Enabled P Key Audible Bell Beeps Quick Exit Enabled OFF F Key Disabled P Key Silent Quick Exit Disabled Quick Arming Enabled Keys Quick Arming Disabled function keys req code Code Required for Bypassing No Code Required for Bypassing Master Code not Changeable Master Code Changeable TLM Enabled TLM Disabled TLM Audible when Armed TLM Trouble Only when Armed Fourth System Option Code ON AC Trouble Displayed OFF AC Trouble Not Displayed Trouble Light Flashes if AC Fails Trouble L

Related Files