DSC NT9204 v1 0 - Installation Manual - English - Envoy LCD High Current Output Module

File Preview
File Preview
Click below to download for free

Text Preview

Keybus The 4 wire Keybus connection is used by the NT9005 to communicate with a Connect the BLK YEL and GRN terminals to the B Y1 and G2 terminals on the NT9005 control panel The NT9204 can be located up to 500ft from the NT9005 NOTE Do not connect the RED of the NT9204 to the RED the NT9005 red Keybus terminal on the backup communicator module must NOT be to the RED terminal of the NT9204 module All modules must be from the AUX terminal of the NT9204 module 01 to 04 01 to 04 01 to 04 Wire the positive lead of the device to the AUX terminal and the 01 to 04 01 to 04 lead to the required output terminal 01 to 04 01 is supervised If 01 is not used if no continuous load is connected or a siren is connected a 1000 Ohm resistor DSC model EOLR 1 must be con in order to prevent the indication of a trouble condition see below The following is an example of how to wire various devices to the outputs The NT9204 is not suitable for fire alarm annunciation output RED Siren maximum polarity Warranty Security Controls Ltd warrants that for a period of twelve months from the date of purchase the product shall be free of defects in and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Security Controls Ltd shall at option repair or replace the defective equipment upon return of the equipment to its factory This warranty applies only to defects in and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties whether expressed or and of all other obligations or liabilities on the part of Digital Security Controls Ltd This warranty contains the entire warranty Digital Controls Ltd neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct or indirect or consequential damages loss of anticipated profits loss of time any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Digital Security Controls Ltd recommends that the entire system be completely tested on a regular basis However despite frequent and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your authority to use this equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with the manufacturer may cause interference to radio and television reception It has been type tested and found to comply with the limits for Class B device accordance with the specifications in Subpart of Part 15 of FCC Rules which are designed to provide reasonable protection against such in any residential installation However there is no guarantee that interference will not occur in a particular installation If this does cause int erference to television or radio reception which can be determined by turning the equipment off and on the user is to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the booklet prepared by the FCC useful to Identify and Resolve Radio Television Interference Problems This booklet is available the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 Digital Security Controls Ltd Canada 1 800 387 3630 in Canada 29005911 R003 all comments concerning this to pubs dscltd com NT9204 Installation Instructions NT9204 module can be used for different applications If a LINKS2X50 or communicator is to be connected to the NT9005 the NT9204 must be used step up the 6V Keybus from the NT9005 to a 12V Keybus in order for these to function properly If an external siren is needed on the system the can be used as it will provide up to 1.0A of current battery backup and required to drive a siren The NT9204 can also be used as a programmable expander If more than 2 PGM outputs are required the NT9204 can be to the system to provide a total of four outputs the NT9005 for use with NT9204 order for the NT9005 and NT9204 to work with each other in Section 018 of the programming Option 1 Keybus Enabled must be ON 1 Descriptions Devices that require from the NT9204 shall UL Listed for the intended and operate over range 11.5 12.5VDC battery requirements and time refer to Table 1 Battery model BD7 12 60Hz YEL GRN TAM O2 O3 O4 2 40VA PTD 1640 OTHER Refer to the Specifications Chart above for the maximum current draw Supervised the NT9204 requires a 16V 40VA transformer Connect the primary the transformer to an unswitched AC source maximum current draw is 0.5A and the secondary of the transformer to these terminals This terminal is used to provide power for devices modules Please refer Table 1 for maximum ratings Connect the positive lead of powered devices to and the negative to the proper output terminal O1 to O4 This can be used to tamper the cabinet in which the NT9204 is mounted Connect normally closed NC switch across TAM and BLK If the tamper is not being used a piece of wire across TAM and BLK to remove the trouble condition Supply Four High Current Module 1 O The 4 wire Keybus connection is used by the NT9005 to communicate with a Connect the BLK YEL and GRN terminals to the B Y1 and G2 terminals on the NT9005 control panel The NT9204 can be located up to 500ft from the NT9005 NOTE Do not connect the RED of the NT9204 to the RED the NT9005 red Keybus terminal on the backup communicator module must NOT be to the RED terminal of the NT9204 module All modules must be from the AUX terminal of the NT9204 module 01 to 04 01 to 04 01 to 04 Wire the positive lead of the device to the AUX terminal and the 01 to 04 01 to 04 lead to the required output terminal 01 to 04 01 is supervised If 01 is not used if no continuous load is connected or a siren is connected a 1000 Ohm resistor DSC model EOLR 1 must be con in order to prevent the indication of a trouble condition see below The following is an example of how to wire various devices to the outputs The NT9204 is not suitable for fire alarm annunciation output RED Siren maximum polarity Warranty Security Controls Ltd warrants that for a period of twelve months from the date of purchase the product shall be free of defects in and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Security Controls Ltd shall at option repair or replace the defective equipment upon return of the equipment to its factory This warranty applies only to defects in and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper of the equipment foregoing warranty shall app

Related Files