DSC Partition Programming PC1616 1832 1864 V4 2

File Preview
File Preview
Click below to download for free

File Data

Name dsc-partition-programming-pc1616-1832-1864-v4-2-5964382017.pdf
Type PDF
Size 627.62 KB
Downloads

Text Preview

Notes Partition Programming PC1616 1832 1864 V4.2 SERIES PC1616 1832 1864 V4.2 PC1616 supports 2 true partitions The PC1832 supports 4 true partitions The PC1864 supports 8 true Each partition can have individual user codes keypads zones entry and exit delay times and numbers if Contact ID or Pulse format is programmed Sirens can be partitioned using PGMs or a siren could be used for all partitions if it is connected to the Main Bell Output partitions is a six step process user codes to partition 1 8 keypads to partition 1 8 zones to partition 1 8 entry exit delay times to partition 1 8 separate sirens to partition 1 8 Optional separate account numbers for partition 1 8 Contact ID and Pulse Format Only 1 Program User Codes to Partition 1 8 Enter Access Code Programming enter Access Code Programming perform the following 5 Master Code Enter Access Code Programming keypads will turn ON the appropriate LED if the user code is programmed PK5500 keypads indicate which codes are programmed by displaying the letter beside each PK5501 keypads flash the number of all access codes programmed Enter the Access Code Number the Access Code Number 39 User Codes 95 Regular User Codes Code Enter the Arm Disarm Code the new four digit code To delete a code press the key instead of entering a 4 digit code Page 42 Assign the User Codes to a Partition assign a user to a partition enter 95 The Master Code User 40 is always assigned to all partitions to access code partition assignment code number on or off the appropriate option or PK5501 keypad 1 2 3 4 5 6 7 8 keypad 1 2 3 4 5 6 7 8 1 enable disable 2 enable disable 3 enable disable 4 enable disable 5 enable disable 6 enable disable 7 enable disable 8 enable disable 1 enable disable 2 enable disable 3 enable disable 4 enable disable 5 enable disable 6 enable disable 7 enable disable 8 enable disable Assign User Codes Attributes Optional User Code has attributes assigned to it assign attributes to a User Code enter 95 This is not available for the Master Code User 40 to access code attributes Code number on or off the appropriate option or PK5501 keypad 1 2 3 4 7 8 can enter User Code Programming section with this code Reporting Code is sent whenever this code is entered Bypass enable disable enable disable Squawk enable disable Code Page 43 keypad Bypass Access Squawk can enter User Code Programming section with this code Reporting Code is sent whenever this code is entered Bypass enable disable Access enable disable Squawk enable disable 1 Squawk Arm 2 Squawk Disarm Code One Time Use finished program access code attributes press to exit Attributes 5 6 are for future use After the attributes are programmed for the user code and is pressed the will go back to regular access code programming 2 Program Keypads to Partition 1 8 Partition 2 8 Enable 2 through 8 must be enabled before keypads assigned to a partition 2 8 will operate enable partition 2 to 8 perform the following 8 Installer Code 201 2 to turn ON option 2 3 to turn ON option 3 4 to turn ON option 4 5 to turn ON option 5 6 to turn ON option 6 7 to turn ON option 7 8 to turn ON option 8 Installer Programming Partition 1 to 8 Enable Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 Keypad Assignment the Partition Assignment and Slot of each keypad To assign the keypad perform the 8 Installer Code 000 0 Installer Programming Keypad Assignment Section Partition and Slot Section a two digit number The first number represents the partition assigned to the keypad data 0 data 1 data 2 data 3 data 4 data 5 data 6 data 7 data 8 Global Mode Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 second digit represents the supervisory slot Each keypad MUST have a different slot number data 1 to 8 for supervisory slot 1 to 8 same procedure must be performed on each keypad Keypads must each be assigned to a specific slot for the keypads to be properly Page 44 a PK5500Z keypad is connected to the panel it must be assigned to slot 8 for purposes In addition only one PK5500 Z can be assigned to Slot 8 LCD programming changes are made using the DLS software the keypad to slot 8 will transmit the changes to all the other PK5500Z keypads on system after the download is complete Module Supervisory Reset all modules are automatically detected and supervised by the panel within the first minute being connected a Module Supervisory trouble condition may occur after keypad slot are changed After all keypads have been assigned to a Partition and Slot perform following to perform a Module Supervisory Reset 8 Installer Code 902 Installer Programming Module Supervision Reset 1 minute verify what modules are present perform the following 903 Module Supervision Display keypad will display the modules present LED keypads will be limited to the number of modules it can display To determine LED represents which module refer to the Installation Manual Section 903 3 Program zones to partition 1 8 Programming Zone Definitions must be defined before they will operate On the POWER SERIES 39 different zone are available Enter the correct section and program the 2 digit number corresponding the required zone definition 001 Zones 1 to 16 002 Zones 17 to 32 003 Zones 33 to 48 004 Zones 49 to 64 Programming Zone Attributes Optional attributes are used to customize the operation of each zone There are 64 sections available 101 for zone 1 to Section 164 for zone 64 Each Section has 9 toggle options Turn the option ON or OFF depending on the required operation 1 Zone audible silent 2 Steady bell output pulsing bell output 3 Door chime enable disable 4 Manual bypass enable disable 5 Force arm enable disable 6 Swinger shutdown enable disable 7 Transmission delay enable disable 8 Wireless zone enable disable 9 Cross Zone enable disable 14 NC Zone Wiring loop 15 EOL Zone Wiring loop 16 DEOL Zone Wiring loop Options 14 15 16 apply to first 8 zones only If more than one of these options are then lowest numbered option is enabled E g If Option 14 and option 15 enabled then the zones are configured as normally closed loops Page 45

Related Files