DSC PC1404RKZ - Installation Guide
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc1404rkz-installation-guide-9132567840.pdf |
---|---|
Type | |
Size | 2.41 MB |
Downloads |
Text Preview
PC1404RKZ Installation Instructions Instrucciones de de Instala d Please refer to the System Installation Manual for information on limita regarding product use and function and information on the limitations as to liability of manufacturer Por favor refi al Manual de Instalaci del Sistema para sobre las limitaciones referentes al uso y funcionamiento del producto e infor sobre las limitaciones relativas a la responsabilidad del fabricante Por favor refira se ao Manual de Instala do Sistema para sobre as limita referentes ao uso e funcionamento do produto e informa sobre as limita relativas responsabilidade do fabricante Ce manuel contient des informations sur les restrictions concernant le et l du produit et des informations sur les restrictions en ce qui con la responsabilit du fabricant La totalit du manuel doit lu attentivement COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer instructions may cause interfer to radio and television reception It has been type tested and found to comply with limits for Class B device in accordance with the specifications in Subpart of 15 of FCC Rules which are designed to provide reasonable protection against interference in any residential installation However there is no guarantee that will not occur in a particular installation If this equipment does cause to television or radio reception which can be determined by turning the off and on the user is encouraged to try to correct the interference by one or of the following measures the receiving antenna the alarm control with respect to the receiver the alarm control away from the receiver the alarm control into a different outlet so that alarm control and receiver are different circuits necessary the user should consult the dealer or an experienced radio television tech for additional suggestions The user may find the following booklet prepared by FCC helpful to Identify and Resolve Radio Television Interference Prob This booklet is available from the U S Government Printing Office Washing D C 20402 Stock 004 000 00345 4 Class B digital apparatus complies with Canadian ICES 003 appareil num de la classe B est conforme la norme NMB 003 du Canada trademarks logos and service marks displayed on this document are registered in the States or other countries Any misuse of the trademarks is strictly prohibited and International Ltd will aggressively enforce its intellectual property rights to the fullest of the law including pursuit of criminal prosecution wherever necessary All trade not owned by Tyco International Ltd are the property of their respective owners and used with permission or allowed under applicable laws Product offerings and specifica are subject to change without notice Actual products may vary from photos Not all include all features Availability varies by region contact your sales representative Installation Instructions PC1404RKZ keypad presents system status using LEDs along with symbols and numbers The can be used on security systems with up to 8 zones The PC1404RKZ is compatible with the security system These instructions shall be used in conjunction with the Installation Manual of PC1404 alarm controller Supply voltage 7VDC 14.5VDC Compatible control panel keybus connection provided by DSC Connects to control panel via 4 wire keybus One keypad zone input Current draw 120mA maximum Optional tamper version Four programmable function keys Ready green Armed red and Trouble amber status lights This keypad is available to order with white WH or yellow YEL LED PC1404RKZ package includes the following parts one PC1404RKZ keypad three mounting screws three anchors for wall mounting screws one end of line resistor the keypad where it is accessible to designated points of entry and exit Once a dry and secure is selected perform the following steps to mount the keypad Remove the keypad frontplate by inserting a screwdriver into the slots located on the top of the keypad Remove the keypad backplate by inserting a screwdriver into the slots located near the tamper switch set of Installation Instructions keypad inner door labels of the backplate and prying up to remove the backplate Secure the keypad backplate to the wall in the desired location Lift the keypad door Use all screws provided Use the plastic anchors supplied if the unit is to be mounted on drywall To use the keypad tamper insert the supplied tamper switch into the opening located in centre of the backplate and secure the tamper to the wall with a screw For tamper use the backplate should be mounted on a smooth flat surface If mounting a rough surface fasten the enclosed surface tape to the wall to even out the surface where the tamper will be positioned Before attaching the keypad to its backplate complete the keypad wiring as described in next section panel Before wiring the unit ensure that all power AC transformer and battery is disconnected from the Connect the four Keybus wires from the control panel red black yellow and green to the terminals RED BLK YEL GRN Consult the diagram below Connect a device such as a door contact to the ter of the PC1404RKZ This eliminates the need to wires back to the control panel for the device To the zone run one wire from the device to the terminal and the other wire from the device to the black terminal For powered devices run the red to the RED positive terminal and the black wire the BLK negative terminal When using end of line connect the zone according to one of the outlined in your system Installation Manual Z Zone Input Power all wiring is complete apply power to the control panel Connect the battery leads to the battery Connect the AC transformer more information on control panel power specifications see the control panel Installation Manual Do not connect the power until all wiring is complete the Keypad all wiring is complete and the keypad is fixed on the wall enter a 2 digit number that tells the the partition and slot assignment of the keypad your system has partitions assign the keypad to a partition 1st digit slot assignment 2nd digit tells the panel which keypad slots are occupied The panel can then a keypad supervision trouble when the keypad is detected as missing There are eight available for keypads PC1404RKZ keypads are always assigned to slot 1 by default Each keypad must be to its own slot 1 to 8 each keypad installed on the system Enter Installer Programming by pressing 8 Installer Code Press 000 for Keypad Programming Press 0 for Partition and Slot Assignment Enter a two digit number to specify the partition and slot assignment If your system does not have partitions enter 1 for the first digit If the first is incorrectly programmed with a value greater than 1 the keypad will not when connected to a single partition system Press and hold the 1 key on the then re enter section 000 0 to correct the programming Press the key twice to exit programming After assigning all keypads perform a supervisory reset by entering 8 Installer Code 902 panel will now supervise all assigned keypads and enrolled modules on the system Save Mode power save mode is enabled and AC power fails all keypad lights including backlighting shut off keypad lights will come back ON after a keypress entry delay audible alarm or keypad buzzer except door chime The keypad lights will return to the off state after 30 seconds of no If the AC fail condition is restored the keypad lights will be reactivated Icons Status Status Status Status Memory Memory green ready status icon is on when the system is ready to red armed status icon is on when the system has been armed trouble status icon is lit when there is a trouble present on system