DSC PC1500 v4 0 - Installation Manual - English - ClassicSeries 6 Zone Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

INSTALLATION device complies with Parts 15 and 68 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful and 2 this device must accept any interference received including interference that may cause undesired operation Registration Number F53CAN 61031 AL E REN 0.0B IN CANADA Type RJ31X FOR UL INSTALLATIONS equipment is UL listed in accordance with standard UL1023 Household Burglar Alarm System Units standard Household Fire Warning Units and UL1635 Digital Alarm Communicator System Units equipment has the capability of being programmed for operational features that are not allowed for UL recognized To stay within the standard for household applications the installer should use the following guidelines configuring the system components of the system should be UL listed for the intended application Note elsewhere in this manual for smoke detectors and battery to be used with this equipment this system is configured for the installer should refer to NFPA Standards 74 for details on locating detectors When the Fire feature is enabled there must be at least one UL recognized indoor Fire Alarm Signalling Appliance Maximum allowed entry time 45 seconds allowed exit time 60 seconds allowed bell cutoff time 4 minutes bypass must be enabled so that a user code is required to bypass zones installer should caution the user to NOT give system information to casual users for example Access bypass methods etc to babysitters or home service people Only the use code should be to the casual user installer should advise the user and note in the user manual Service organization name and telephone number The programmed exit time The programmed entry time programming must be disabled manual is for the PC1500 software version 4.0 OF CONTENTS FOR LOCATING SMOKE DETECTORS FUNCTIONS the Panel 2 the Keypad 2 Power Connection 2 Terminal Connections 2 Wiring 2 Connection 2 Zone Wiring 3 Zone Wiring 3 Power Wiring 3 Connection 3 Line Wiring 3 5 Code 5 Master Code 5 Programming Code 5 5 Arming 5 Without Entry Delay 5 5 Bypassing 5 Conditions 6 Memory 6 Callup Command 6 Programming Command Code 6 Reset 7 Function Commands Code 7 the Clock Code 1 7 Auto Arm Time Code 2 7 ON OFF Code 4 7 ON OFF Code 5 7 Chime ON OFF Code 6 7 Test Code 8 8 Test ON OFF Code 0 8 Output Command or Code 8 Programming Command Code 8 without Entry Delay Code 8 For The Night 8 when Armed 8 Command when Disarmed 8 Zones 8 9 9 Data Review 9 Data Display

Related Files