DSC PC1555 v2 0 - Installation Manual - English - PowerSeries 6-32 Zone Control Panel (50 300)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc1555-v2-0-installation-manual-english-powerseries-6-32-zone-control-panel-50-300-8361924507.pdf |
---|---|
Type | |
Size | 1.44 MB |
Downloads |
Text Preview
System Introduction Software Support PC1555 uses DLS 1 v6.3 and up Zone Configuration Six fully programmable zones system expandable to eight using keypad zone inputs and wireless zones 38 access codes one master code one maintenance code duress codes two supervision codes and 32 general codes 27 zone types 8 programmable zone attributes Normally closed single EOL and double EOL zone wiring Eight wireless zones available using the PC5132 Wireless Alarm Output Supervised Bell Output current limited at 3 amps 12VDC Steady or Pulsed Output Memory Does not lose programming or system status on complete AC Battery failure Outputs One programmable voltage output and one programmable output input 21 programmable options PGM1 50mA PGM2 300mA 1.5 Amp Regulated Power Supply 550 mA Auxiliary Supply 12 VDC Positive Temperature Coefficient PTC components replace Supervision for loss of AC power low battery Internal clock locked to AC power frequency Requirements Transformer 16.5 VAC 40VA Battery 12 volt 4 Ah minimum rechargeable sealed lead battery Keypad Specifications Three keypads available PC1555RKZ eight zone LED keypad with zone input PC5508Z eight zone LED keypad with zone input LCD5500Z Alphanumeric keypad with zone input All keypads have five programmable function keys Connect up to eight keypads 4 wire Quad connection to Keybus Built in piezoelectric buzzer Communicator Specifications Supports major communication formats including SIA and ID Event initiated personal paging Three programmable telephone numbers Two account numbers Supports LINKS1000 cellular communication Supports LINKS2X50 Long Range Radio Transmitter DTMF and pulse dialing DPDT line seizure Anti jam feature Split reporting of selected transmissions to each telephone Supervision Features PC1555 continuously monitors a number of possible trouble including AC power failure Trouble by zone Tamper by zone Fire trouble Telephone line trouble Failure to communicate Low battery condition Bell output trouble Module fault supervisory or loss of internal clock AUX Power Supply Trouble Alarm Prevention Features Audible Exit Delay Audible Exit Fault Communication Delay Urgency on Entry Delay Quick Exit Features Auto Arm at specified time Keypad activated alarm output and communicator test All modules connect to the system via a four wire Keybus up 1000 from main panel An event buffer which records the past 128 events with both time and date at which they occurred buffer can be using PC5400 serial interface module or viewed with LCD5500Z keypad Supports the addition of the PC5132 Wireless receiver for of wireless devices Uploading and downloading capability Local downloading capability through the use of the PC LINK Added Keybus fault protection clock and data outputs have programmed to withstand shorts to 12v to prevent panel damage Additional Devices maximum of eight keypads can be connected to the control and can be any combination of the following listed PC1555RKZ 8 zone LED keypad with function keys number 1 5 and zone input PC5508Z 8 zone LED keypad with function keys and zone LCD5500Z LCD keypad with function keys and zone input Wireless Receiver PC5132 Wireless Receiver can be used to connect up to 8 devices to the system All devices are spread spectrum MHz fully supervised devices which use standard or alkaline batteries additional devices are available They are as follows Wireless Motion Detector wireless motion detector can be used in conjunction with PC5132 wireless receiver to include wireless space The unit comes with four batteries Wireless Universal Transmitter wireless universal transmitter can be used in conjunction the PC5132 Wireless Receiver module to add wireless door window contacts The universal transmitter comes with three batteries and has built in contacts The unit also provides for connecting hardwire contacts Wireless Smoke Detector wireless smoke detector can be used in conjunction with PC5132 wireless receiver to include wireless smoke The unit comes with six batteries Wireless Slimline Universal Transmitter wireless slimline universal transmitter can be used with the wireless receiver to add wireless door or window The unit is smaller than the WLS905 The unit comes three batteries and has built in contacts Wireless Panic Pendant wireless panic pendant can be used in conjunction with the Wireless Receiver to include personal protection used the unit will indicate a non medical emergency to central station unit comes with 1 mini 12V battery The disposable unit is sealed and the battery is not user serviceable Wireless Key wireless key can be used in conjunction with the PC5132 receiver to include a simple and mobile method of arming disarming the system The unit comes with three photo 1.5V batteries which can be replaced by the user PC1555 system can have a maximum of 16 wireless keys Wireless Handheld Keypad wireless handheld keypad can be used in conjunction with PC5132 Wireless Receiver to include a simple and mobile of arming and disarming the system The unit comes three batteries PC1555 system can have a maximum of four wireless keypads Printer Module module will give you the advantage customers who like idea of a permanent record of and closings but are off by the additional monthly charge In addition as reports are generated in real the customer will not have to wait for a monthly report from monitoring station PC5400 Printer Module will allow the panel to print out all that occur on the system to any serial printer The will contain the time date and the event that occurred 1000 Cellular Communicator LINKS 1000 Cellular Communicator provides an efficient method for adding cellular backup to the security The LINKS 1000 Cellular Communicator can be used different ways as the sole communicator for the panel as backup for either or both phone numbers or as a redundant to the land line communicator where the panel will call the land line and via the LINKS The unit comes in its own with antenna and requires a separate battery and see Section 5.26 1000 Cellular different cabinets are available for the PC1555 modules are as follows Cabinet control cabinet for the PC1555 main panel Dimensions x 298mm x 78mm 11.3 x 11.7 x 3 approximately Cabinet with Removable Door control cabinet for the PC1555 main panel Dimensions x 235mm x 78mm 8.4 x 9.25 x 3 approximately Cabinet to house the PC5400 Printer Module Dimensions x 178mm x 65mm 9 x 7 x 2.6 approximately Out of the Box verify that the following components are included in system one PC5003C main control cabinet one PC1555 main control circuit board one PC1555RKZ keypad with zone input one Installation Manual with programming worksheets one Instruction Manual for the end user one hardware pack consisting of one mylar cabinet label four plastic circuit board standoffs fourteen 5600W one 2200W one 1000W ground connection assembly one cabinet door plug 2.2K resistor 1K resistor 5.6K resistors Started Steps following sections provide a thorough description of how to and configure devices and zones following steps are provided to assist you with installing the