DSC PC1575 v1 0 - Installation Manual - English - PowerSeries 6 zone Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

PC1575 System Introduction Specifications Panel Specifications standard option one low current PGM output one low current PGM output input 2 wire smoke option one low current PGM and one high current PGM output input Zone Configuration Six fully programmable zones Seven Access Codes five User one Master and a Master code Normally Closed Single EOL Double EOL 2 wire Smoke Zone or Auxiliary Zone 21 Zone Types 6 Programmable Zone Options Alarm Output Supervised Bell Output current limited at 3 amps 12VDC Steady or Pulsed Output Memory Does not lose programming or system status on AC and Battery failure Outputs One programmable voltage output and one voltage output input 30 programmable PC1575 standard option one low current 50mA PGM output one low current 50mA PGM output input PC1575 2 wire smoke option one low current 50mA PGM output one high current 300mA PGM output input 2 wire smoke detector capability read Appendix D Output Options for important information 1 Amp Regulated Power Supply 550 mA Auxiliary Supply 12 VDC Positive Temperature Coefficient PTC components fuses Supervision for loss of AC Power Low Battery Internal Clock Locked to AC Power Frequency Requirements Transformer 16.5 VAC 40VA Battery 12 volt 4 Ah minimum rechargeable sealed acid Keypad Specifications Three Different Keypads Available PC5506 six zone LED keypad LCD5500 Alphanumeric keypad PC1575RK six zone LED keypad SL 75 six zone LED keypad The PC5506 and LCD5500 keypads have 5 Fully Function Keys Connect up to 8 Keypads Four Wire Quad Connection to KEYBUS Built in Piezoelectric Buzzer Communicator Specifications Supports Major Formats including SIA and Contact ID Event Initiated Personal Paging Three Programmable Phone Numbers Two Account numbers Supports LINKS 1000 Cellular Communication DTMF and Pulse Dialing DPDT Line Seizure Anti jam Feature Split Reporting of Selected Transmissions to Each Number Supervision Features PC1575 continuously monitors a number of possible conditions including AC Power Failure Trouble by Zone Tamper by Zone Fire Trouble Telephone Line Trouble Failure to Communicate Low Battery Condition Bell Output Trouble Module Fault Supervisory or Loss of Internal Clock Power Supply Fault Tamper Alarm Prevention Features Audible Exit Delay Audible Exit Fault Communication Delay Urgency on Entry Delay Quick Exit Features Auto Arm at Specified Time Keypad Activated Alarm Output and Communicator All modules connect to the system via a four wire up to 1000 from main panel Event Buffer can be printed using PC5400 RS232 Serial module Supports the ESCORT 5580 Voice Prompt Module with Control An Event Buffer which records the past 100 events with the time and date at which they occurred Uploading and Downloading capability Local Downloading capability through the use of the Adaptor Installation equipment is UL Listed in accordance with UL1023 Burglar Alarm System Units UL985 Household Warning System Units UL1635 Digital Alarm Annunciator Units UL365 Police Station Connected Burglar Units and Systems UL609 Local Burglar Alarm Units Systems UL1610 Central Station Burglar Alarm Units equipment has the capability of being programmed for features that are not allowed for UL Listed Systems to to to being connected to accessories not permitted Refer to to E for summary of requirements E for summary of requirements E for summary of requirements E for summary of requirements E for summary of requirements Downlook Video Transmission Module Downlook Still Frame Video Transmission Module DLM is the ideal solution for all business and residential which require visual surveillance but where presence of on site security personnel is impossible or unaffordable is the smart and inexpensive way to add visual to your regular remote alarm signalling system your demand for tighter security on a tight budget added visual protection will reduce the incidence of alarms as well as surveillance costs thus improving security protection more information regarding the Downlook Video Module please consult the DLM 1 DLM 4 Manuals LINKS 1000 Cellular Communicator LINKS 1000 Cellular Communicator provides an efficient method for adding cellular back up to the system The LINKS 1000 Cellular Communicator be used three different ways as the sole communicator the panel as a back up for either or both phone numbers as a redundant back up to the land line communicator the panel will call both the land line and via the LINKS unit comes in its own cabinet with antenna and requires see Section 5.23 see Section 5.23 see Section 5.23 separate battery and transformer see Section 5.23 see Section 5.23 1000 Cellular Communicator 1000 Cellular Communicator 1000 Cellular Communicator 1000 Cellular Communicator 1000 Cellular Communicator Cabinets different cabinets are available for the PC1575 They are as follows Cabinet control cabinet for the PC1575 main panel Dimensions x 298mm x 78mm 11.3 x 11.7 x 3 approximately Cabinet to house the PC5580 ESCORT Module or the Printer Module Dimensions 229mm x 178mm x 9 x 7 x 2.6 approximately Out of the Box verify that each of the following components is in your system one PC1575 main control cabinet one PC1575 main control circuit board one PC1575 keypad LED keypad or LCD keypad one Installation Manual including Programming one Instruction Manual for the end user one hardware pack consisting of 5.6K resistors four plastic circuit board standoffs twelve 5600W one 2200W one 1000W EGND Assembly one cabinet door plug 2.2K resistors 1K resistor Additional Devices Keypads ESCORT5580 Module maximum of eight keypads can be connected to the panel and can be any combination of the following PC5506 6 zone LED keypad with function keys LCD5500 LCD keypad with function keys PC1575RK 6 zone LED keypad SL 75 6 zone Slimline LED keypad are many benefits to the ESCORT5580 module a security system The module will turn touch tone phone in the world a fully functional keypad the security a customer would feel if they had the to arm disarm and check status of their alarm system at the office or on vacation touch tone phones in the home also become system For example at bedtime the phone beside the bed be used to arm the system The addition of the may reduce the cost of the overall installation the need for additional keypads and the labour of wires ESCORT5580 will also act as a tutor for the system By clear easy to understand sentences the voice module guide the user through functions they may otherwise difficult to navigate Programmable zone labels up to words each from our library of over 240 words makes the even easier to use module also has a built in power line control interface can control up to 32 power line control devices for and temperature control giving you the power to home automation in a very cost effective manner can be activated individually as a group by or can be activated when an event occurs on the such as an alarm are just a few of the applications available with the of the ESCORT5580 module For more information refer to the ESCORT5580 Installation Manual module will give you the

Related Files