DSC PC1616 1832 1864 v4 6 - Installation Manual - ENG - R004

File Preview
File Preview
Click below to download for free

Text Preview

PC1616 PC1832 PC1864 v4.6 NA Guide This manual contains information on limitations regarding product use and function and on the limitations as to liability the manufacturer The entire manual should be read carefully of Contents for Locating Smoke Detectors and CO Detectors ii 1 Installation Wiring 1 1 Keybus Wiring 3 Zone Wiring 3 Zone Expanders 3 Bell Wiring 3 AUX Power Wiring 4 PGM Wiring 4 Carbon Monoxide Detector Wiring 4 Telephone Line Wiring 5 Ground 5 Battery 5 AC Wiring 5 RFK5500 and RFK5564 Easy Wireless Enrollment Procedure 5 2 User Commands 6 Away Arming 6 Stay Arming 6 Disarming 6 cid 2 Commands 6 Function Keys 8 3 Programming 9 Template Programming 9 DLS Programming 9 Advanced Keypad Programming 9 4 Programming Descriptions 11 5 Programming Worksheets 29 Index to Programming Worksheets 29 A Reporting Codes 55 B UL Listed Commercial and Residential Installations 57 C SIA False Alarm Reduction 58 D Troubleshooting Guide 59 E Template Programming 63 F Communicator Format Options 65 INSTRUCTIONS FOR SERVICE PERSONS 67 COMPLIANCE STATEMENT 69 PC1616 PC1832 PC1864 for Locating Smoke Detectors and CO Detectors following information is for general guidance only and it is recommended that local fire codes and regulations be consulted when locating installing smoke and carbon monoxide alarms Detectors indicates that all hostile fires in homes generate smoke to a greater or lesser extent Detectable quantities of smoke precede detectable of heat in most cases Smoke alarms should be installed outside of each sleeping area and on each level of the home recommends that additional smoke alarms beyond those required for minimum protection be installed Additional areas that should be include the basement bedrooms especially where smokers sleep dining rooms furnace and utility rooms and any hallways not by the required units smooth ceilings detectors may be spaced 9.1m 30 feet apart as a guide Other spacing may be required depending on ceiling height air the presence of joists uninsulated ceilings etc Consult National Fire Alarm Code NFPA 72 CAN ULC S553 02 or other appropri national standards for installation recommendations Do not locate smoke detectors at the top of peaked or gabled ceilings dead air space in these locations may prevent smoke detection Avoid areas with turbulent air flow such as near doors fans or windows Rapid air movement around the detector may prevent smoke from the unit Do not locate detectors in areas of high humidity Do not locate detectors in areas where the temperature rises above 38oC 100oF or falls below 5oC 41oF Smoke detectors should always be installed in USA in accordance with Chapter 11 of NFPA 72 the National Fire Alarm Code 11.5.1.1 required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms be installed as follows In all sleeping rooms and guest rooms Outside of each separate dwelling unit sleeping area within 6.4 m 21 ft of any door to a sleeping room the distance measured along a path of travel On every level of a dwelling unit including basements On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics In the living area s of a guest suite In the living area s of a residential board and care occupancy small facility 1 2 3 3a 4 Detectors monoxide gas moves freely in the air The human body is most vulnerable to the effects of CO gas sleeping hours For maximum protection a CO alarm should be located outside primary sleeping or on each level of your home Figure 5 indicates the suggested locations in the home The elec sensor detects carbon monoxide measures the concentration and sounds a loud alarm before a harmful level is reached NOT place the CO alarm in the following areas Where the temperature may drop below 10 or exceed 40 Near paint thinner fumes Within 5 feet 1.5 meters of open flame appliances such as furnaces stoves and fireplaces In exhaust streams from gas engines vents flues or chimneys In close proximity to an automobile exhaust pipe this will damage the detector MONOXIDE DETECTOR 5 1 Installation Wiring Installation Guide provides the basic installation wiring and programming information required to program the PowerSeries PC1616 and PC1864 control panels All necessary information required to meet UL Listing requirements is included in this document 1 Installation Wiring Summary Of THE BOX 1 cid 3 1 cid 3 1 cid 3 1 cid 3 2 cid 3 1 cid 3 5 cid 3 16 cid 3 1 cid 3 1 cid 3 1 cid 3 Module Guide Manual Label Door Plug Resistors R

Related Files