DSC PC1616 PC1832 PC1864 - Programming Worksheet (Fold-out) - Eng- V4 1

File Preview
File Preview
Click below to download for free

Text Preview

29007177R002 Security Controls Canada www dsc com in Canada Option Codes 401 Back Enabled Can Enable DLS Window Machine Double Call Enabled Def ON OFF Event Buffer Upload Enabled Initiated Call Up Enabled Back Disabled Use Use Use Initiated Call Up Disabled Event Buffer Upload Disabled Machine Double Call Disabled Can NOT Enable DLS Window DLS Downloading Telephone Number 32 Digits DOWNLOADING Code 403 ID Code 404 Def 161600 183200 186400 6 Hexadecimal Digits 6 Hexadecimal Digits 6 Hexadecimal Digits Answering Machine Double Call Timer 060 Seconds Number of Rings to Answer On 000 Rings Initiate PC Link Downloading 499 Installer Code 499 FAR CP 01 Only Audible Steady Chime Bypass Force Arm Swinger TX Delay Wireless Zn Cross Zone Delay Definition Null Zone Not Used Delay 1b Delay 2b Instantb Interiorb Interior Stay Awayb Delay Stay Awayb Delayed 24Hr Fire Hardwiredf Standard 24Hr Fire Hardwired 24Hr Supervisory 24Hr Supervisory Buzzerb 24Hr Burglaryb 24Hr Holdupb PROGRAMMING ATTRIBUTES 2 3 4 5 6 7 8 9 Definition ATTRIBUTES 2 3 4 5 6 7 8 9 Definition cid 2 cid 2 cid 2 cid 2 cid 2 cid 2 cid 2 24Hr Gasb 24Hr Heatingb 24Hr Auxiliary Medical 24Hr Panicb 24Hr Emergencyb 24Hr Sprinklerb 24Hr Waterb 24Hr Freezeb 24Hr Latching Tamperb Momentary Keyswitch Armb Maintained Keyswitch Armb Not Used Interior Delayb cid 2 ATTRIBUTES 2 3 4 5 6 7 8 9 24Hr Non alarmb Auto Verified Fire Fire Supervisory Day Zoneb Instant Stay Away Future Use Future Use 24Hr Bell Buzzer Future Use Night Zone Delay 24Hr Fire Wireless f Standard 24Hr Fire Wireless f cid 2 cid 2 cid 2 cid 2 cid 2 cid 2 cid 2 INSTALLER FUNCTIONS ZONE LABEL HERE if APPLICABLE Refer to Keypad Installation Manual TYPE ATTRIBUTES 9 SERIAL ASSIGNMENT REPORTING CODES Def FF REST REST Keypads are required for 24Hr buzzer zone PC1864 PC1832 support 32 wireless zones PC1616 supports 16 wireless zones burglary applications only residential fire applications only profile Generic offset separations profile 133 lpi at 45 degrees CP 01 SIA FAR v4.1 WORKSHEET Programming Worksheet provides all programming sections and default values for the PC1616 PC1832 and PC1864 programming worksheet shall be used in conjunction with the PowerSeries PC1616 PC1832 PC1864 Reference Manual which can be obtained from your local dealer or downloaded from DSC website at www dsc com The Reference Manual provides a detailed description of each option Programming Options for the PC1616 PC1832 PC1864 are identical except for number of Zones Partitions and On board PGMs Refer to the table below for available options each model PC1832 PC1864 Zones Zones Zones PGMs to Program 1xPC5108 RF5108 3xPC5108 PC5132 7xPC5108 PC5132 recommends filling in the Programming Worksheet with the required programming information before the system This will reduce the time required to program and will help eliminate errors enter Installer Programming press The Program light will FLASH on LED Keypads display will change to Section on the keypad error tone indicates the installer code entered is incorrect Press Armed and Ready lights indicate programming status Light ON Light ON Light FLASHING waiting for 3 digit section number waiting for data to be entered waiting for HEX data to be entered cannot enter installer programming while any aprtition is armed or in alarm clear the entry then reenter the installer code Toggle Options the 3 digit programming section number The Armed light will turn keypad will display toggle option status as indicated below the Ready light will turn Type LCD LCD Light ON ON Displayed OFF Light OFF OFF Displayed press the corresponding number on the keypad The change will be displayed OFF toggle an option all the toggle options are configured as required the to exit the programming section The Ready light will turn the Armed light will turn the panel is a local system press addition to the standard digits 0 9 HEX digits can also be programmed in the phone number if required to skip this step A B C D E Supported key key tone search second pause Decimal and Hexadecimal HEX Data The Ready light will turn the 3 digit programming section number The Armed light will turn the data recorded in the Programming Worksheet sections that require multiple 2 or 3 digit numbers the keypad will double beep after each 2 or 3 digit entry moving to the next item on the list After the last digit in the section is entered the keypad will beep rapidly times and exit the program section The Ready light will turn sections that do not require data for every box such as phone numbers press the section after entering all of the required data Ready light will turn the Armed light will turn enter a HEX digit press the to the chart below and press the number corresponding to the HEX digit required Ready light will continue to at any time to exit a programming section and save programming changes key to begin HEX programming The Ready light will FLASH the Armed light will turn key to exit the again to return to normal decimal programming The Ready light will turn C D E F 3 4 5 6 to Exit Installer Programming A B 1 2 Programming exit installer programming press the Armed light is ON key when the panel is waiting for a 3 digit section number and LCD5501Z Keypads programming sections can be viewed from an LED or LCD5501Z keypad a programming section is entered the keypad will immediately display the first digit of information in that section The keypad displays the information using the binary format indicated below Hex data entry instructions 1 2 3 4 Light OFF Light ON the arrow keys or p all the digits in a section have been viewed the panel will exit the section any of the Emergency keys Fire Auxiliary or Panic to advance to the next digit Ready light will turn and the Armed light will turn system will wait for the next three digit programming section number to be entered the key to exit the section Keypads a programming section is entered the keypad will display all

Related Files