DSC PC2550 v1 2 - Installation Manual - English - ClassicSeries 8 Zone Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Remote Keypad Specifications Four wire QUAD hook up and up to 3 keypads per Built in piezoelectric buzzer Full annunciation of zones and system status Nominal current draw 60 mA Dimensions 5.5 x 4.5 x 1 deep 140 x 114 x 25 mm Voltage Specification to the requirements of standards UL985 and it is required to indicate an output voltage of 11 unregulated Typically with normal AC in and a fully battery the output voltage will be 13.8 VDC With off and a discharged battery the voltage will go to 10 Devices that require power from the control panel be capable of normal operation over the voltage of 10 to 14 VDC Communicator Specifications 76 reporting codes Transmits all 10BPS and 20BPS single line and formats Radionics Rounds and Radionics Parity formats Sescoa Superfast format 3 1 4 2 and hexadecimal numbers DTMF and Pulse dialing DPDT line seizure True dial tone detection Anti jam feature Two telephone numbers and two account codes Split reporting of selected transmissions to each number Panel Specifications zones including 8 fully programmable supervised zones EOL resistors Supervised fire zone 1 auxiliary normally open zone 3 keypad activated zones alarm output Bell output mA fused at 5 Amps 11 VDC unregulated Steady or pulsed output memory Does not lose codes or system status on complete AC battery failure output Transistor switch sinks 50 mA to ground Operation controllable through program options 1.5 amp regulated power supply 400 mA auxiliary supply 11 VDC unregulated Separately fused for battery keypad auxiliary supply bell output Supervision for loss of AC power low battery Internal clock locked to AC power frequency Smoke Detector Supply Output Controlled from keypad Q 4 command required 12 volt 4 Ah minimum rechargeable gel cell or sealed battery required 16.5 VAC 40VA 11 x 11.8 x 3.3 deep 279 x 300 x 84 mm 6.5 lbs 3 kg Features PC2550 has many advanced features Features provide the security system design flexibility and advantage necessary to win those demanding jobs make them profitable of these features include EEPROM memory retains all data even on complete AC battery failure Panel powers up in last armed or state before power loss All programmable zones may be selected as one of 10 types including delay auxiliary delay instant interior with home away delay with home away 4 types of 24 hour emergency and supervisory Keypad programming of up to sixteen security codes Zone bypassing from the keypad Individual zone and system function indicators on A keypad activated utility output function for operating door openers cameras or other devices the PC2550 has many features it is not difficult use All keypad commands are similar and are assisted audible and visual cues Programming PC2550 comes with a default program so it is with a minimum of programming It is programmable from the keypad The panel EEPROM memory so that all information is retained if the panel loses both AC and battery power Level Static Lightning PC2550 has been carefully designed and tested to reliable service It is built to take static and induced surges and keep on working Multiple surge filters are on all zone inputs the power the keypad connections the bell output the power supply and the telephone interface A circuit board configuration catches voltage impulses right at the wiring terminals ground planes surround sensitive areas the spread of damaging voltage surges Oxide Varistors MOV are placed in all the areas to further reduce impulses to safe levels MONITOR Circuit when all precautions are taken so that voltage do not cause damage to the control panel it is to cause temporary disruption to the operation the microprocessor causing it to lose track of the sequence The PC2550 is equipped with an Monitor circuit which continually the microprocessor program execution Supervision Features PC2550 continuously monitors a number of possible conditions including An active battery supervision circuit that periodically the battery under load A loss of the AC power supply A supervised circuit trouble condition A telephone line monitoring circuit A bell circuit failure indicates open circuit or fuse A test code feature which transmits a communicator code to the monitoring station at a selected time The test code can be sent at intervals from 1 99 days A bell siren communicator test feature which can be from the keypad TLM Telephone Line Monitoring restoral transmission Testing PC2550 contains a factory default program Any programming required can be done through keypad For many applications all that will be is to enter the telephone number and alarm with keypad entries that are as straight forward as a telephone number If you need help talk to your equipment distributor 1K ohm 1 2 watt end of line resistors from each Z1 to Z8 input to the closest common Connect an end of line resistor between the input terminal and the terminal between and Unless all zone loops are properly with end of line resistors the light will be on and the panel will not arm unless the is on the four keypad wires to the control panel as in the connection drawing completely test the PC2550 including the data it is necessary to connect the panel a digital receiver through a telephone line connection by connecting the telephone terminals on the PC2550 a digital communicator test set such as the DSC DTS The DSC DTS 1 digital communicator test set is an unit which can simulate the telephone dial tone and the receiver hand shake and kiss tones as well as display the data sent out by a digital Also the DTS 1 has a feature makes it ideal for monitoring the transmission communicator and receiver when the PC2550 is to the telephone line you are using a DTS 1 connect the green and red clips to the and terminals and the red and black power clips to the terminals on the PC2550 When power is to the panel press the red local line button on DTS 1 and observe the display window area The indicator should be in the local position testing purposes so that the sound level is not too connect a small buzzer to the and terminals to indicate when the panel is in a 16.5 VAC 40 VA transformer to the Before plugging in the transformer be sure circuit board is not resting on anything metallic which cause a short THE PC2550 WILL NOT START UP IF IS AND THE BATTERY IS LOW the transformer is plugged in there should be on the keypad and the buzzer connected to the terminals may go on for a few seconds The may be on or off the first time the panel is powered last armed disarmed condition is stored in the memory so the panel will always power up in last armed disarmed state If the light is on the default Master Code 1234 to disarm the If the keypad is not active check for the presence AC power at the terminals check the keypad and check the panel fuses all the zones are properly connected with end of line all of the zone lights will be off Note that the will arm only if all zones are properly connected end of line resistors including FIRE circuit so that light is on The keypad should beep several to indicate acceptance of the master code Enter Master Code to arm or di

Related Files