DSC PC2580-Installation Manual-v1-4-English

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc2580-installation-manual-v1-4-english-9034521867.pdf
Type PDF
Size 1.16 MB
Downloads

Text Preview

SPECIFICATIONS Panel Specifications zones including 8 fully programmable supervised zones End of Line including Fire Zone capability 1 Auxiliary Normally Open or Normally Closed Zone 3 keypad activated zones alarm output Bell output 700 mA fused at 5 A 11.0 13.8 VDC Steady or pulsed output Normal or inverted output memory Does not lose codes or system status on complete AC battery failure Programmable outputs Transistor switch sinks 50 mA to ground Operation through program options 1.5 amp regulated power supply 400 mA auxiliary supply 11.0 13.8 VDC Separately fused for battery keypad auxiliary supply bell output Supervision for loss of AC power low battery Internal clock locked to AC power frequency Smoke Detector Supply Output Controlled by keypad Required 12 volt 4 Ah minimum rechargeable gel cell or sealed command battery Supplied 16.5 VAC 40VA 11 11.8 3.3 deep 279 300 84 mm 6.5 lbs 3 kg Keypad Specifications Four wire QUAD hook up Nominal current draw 60 mA Up to 3 keypads per system recommended Maximum keypads per system refer to Keypad and Fire Circuit Information Built in piezoelectric buzzer Full annunciation of zones and system status Dimensions 5.5 4.5 1 deep 114 25 mm Voltage Specification with normal AC in and a fully charged battery output voltage will be 13.8 VDC With AC off and a battery the voltage will drop to 10 volts that require power from the control panel should capable of normal operation over the voltage range 10 to 14 VDC Communicator Specifications 92 reporting codes Transmits all 10 BPS and 20 BPS single line and formats Radionics Rounds and Radionics Parity formats DTMF fast Scantronics slot format Sur Gard 4 3 DTMF with Parity Ademco Contact ID Semidigit Pager Format Sescoa Superspeed format 3 1 4 2 and hexadecimal numbers DTMF and Pulse dialing DPDT line seizure True dial tone detection Anti jam feature 3 telephone numbers and 3 account codes Split reporting of selected transmissions to each number Programming Features EEPROM memory retains all data even on complete and battery failure System powers up in last armed disarmed state before power loss All programmable zones may be selected as one of 10 types including Delay Auxiliary Delay Instant Interior Delay Interior with Home Away Delay Home Away and 3 types of 24 hour emergency supervisory circuits Keypad programming of up to 17 Access Codes Zone bypassing from the keypad Individual zone and system function indicators on 2 keypad activated utility output functions for operating door openers cameras or other devices Optional keypad status light timeout PC2580 features a default program so it is operational a minimum of programming The PC2580 is programmable from the keypad The panel EEPROM memory so that all information is retained if the system loses both AC and battery power Level Static Lightning PC2580 has been carefully designed and tested to reliable service It is built to take static and induced surges and keep on working Multiple surge filters are on all zone inputs the power the keypad connections the bell output the power supply and the telephone interface A circuit board configuration catches voltage impulses right at the wiring terminals ground planes surround sensitive areas the spread of damaging voltage surges Oxide Varistors MOVs are placed in all the areas to further reduce impulses to safe levels Monitor Circuit when all precautions are taken so that voltage do not cause damage to the control panel it is to cause temporary disruption to the operation the microprocessor causing it to lose track of the sequence The PC2580 is equipped with an Monitor circuit which continually the microprocessor program execution Supervision Features PC2580 continuously monitors a number of possible conditions including Double end of line resistor zone supervision to allow both tamper and alarm detection Keypad Tamper Supervision with LED625T or Keypads An active battery supervision circuit that periodically the battery under load A loss of the AC power supply A supervised circuit trouble condition A telephone line monitoring circuit A bell circuit failure indicates open circuit or fuse failure A test code feature which transmits a communicator code to the monitoring station at a selected time the day The test code can be sent at intervals 1 to 99 days It can also be sent every hour on the or every 15 minutes while armed A bell siren communicator test feature which can be from the keypad Telephone Line Monitoring TLM restoral transmission 128 event Event Buffer Testing following items are required for bench testing 1 Single Pole Single Throw SPST switch 1 Single Pole Double Throw Centre Off SPDT switch 2 5600W resistors Testing Set up One of the outer leads A of the SPST switch is connected to the terminal closest to the zone being on The common lead of the SPST B is shorted to the outer lead D of the SPDT switch One 5600W resistor is connected between the two outer leads of the SPDT switch D to F The other 5600W resistor is connected from the common lead to the outer lead of the SPDT E to F The common lead of the SPDT switch E is connected to the zone terminal being worked on normal condition exists when the SPST switch is shorting leads A to B and the SPDT switch is shorting leads to F Below are the zone status conditions and switch settings Switch 1 on AB and switch 2 on EF is a Restoral condition 5600 Ohms Switch 1 on AB and switch 2 on EE is an Alarm condition 11200 Ohms Switch 1 on BC is a Tamper condition open Switch 2 on DE is a Tamper condition short Connections for Bench Testing the four keypad wires to the control panel as shown in the Hook up Diagram in the back of this manual completely test the PC2580 and communicator data it is necessary to connect the system to a digital receiver a telephone line connection or by connecting the telephone terminals on the PC2580 to a digital communicator set such as the DSC DTS 1 The DSC DTS 1 digital communicator test set is an inexpensive unit which can simulate telephone system dial tone and the receiver handshake and kiss off tones as well as display the data transmitted a digital communicator Also the DTS 1 has a feature which makes it ideal for monitoring the transmission communicator and receiver when the PC2580 is connected to the telephone line you are using a DTS 1 connect the red and green telephone clips to the and terminals and connect the red black power clips to the and terminals on the PC2580 When power is applied to the system the local line button on the DTS 1 and observe the display window The indicator should be in the position testing purposes connect a small buzzer to the and terminals to indicate when the system in alarm a 16.5 VAC 40 VA transformer to the terminals Before plugging in the transformer be sure the circuit is not resting on anything metallic which may cause a short circuit THE PC2580 WILL NOT START UP IF IS OFF power is first applied to the system the keypad lights will come ON and the sounder connected to the BELL will sound briefly The light may be ON or OFF the first time power is applied to the system The last condition is stored in the EEPROM memory so the system will always power up in the la

Related Files