DSC PC4010CF - Commercial Fire Installation Guide - English - MAXSYS
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc4010cf-commercial-fire-installation-guide-english-maxsys-2183567940.pdf |
---|---|
Type | |
Size | 1.19 MB |
Downloads |
Text Preview
PC4010CF v3.0 Commercial Fire Installation Guide v1.3 of Contents A Wiring Diagrams PC4010CF Wiring Diagram Connection Zone Circuits 14 PC4701 Wiring Diagram and 2 Wire Smoke 15 PC4010CF Communications Connections PC4701 LINKS2150 LINKS2450 16 PC4702BP Wiring Diagram 17 Battery Lead and AC power Lead for Commercial Fire Systems 17 Sensor Reset for 4 Wire Smoke Detectors 18 PGM Connections 18 AMS 220 Addressable Smoke Detector Connection 18 1 Introduction Introduction 1 Hardware Description and Specifications 1 2 Fire Zone Types Partitions and Fire System Configuration 3 Standard Fire Zone 3 Delayed Fire Zone 3 Auto Verify Fire 4 Waterflow Zone 4 Fire Supervisory Zone 5 PC4701 Zones 5 4 Wire Smoke Detector Zones 5 AMS 220 Addressable Smoke Detector Zones 5 3 PC4702BP Output Programming Alarm Notification Output Types 6 Programming PC4702BP Outputs 6 Fire Bell Options 6 Partitions and Fire System Configuration 7 4 Fire System Operation Manual Signal Silence 8 Automatic Signal Silence Bell Cut Off 8 Signal Silence Inhibit Timer Fire Silence Delay 8 Fire System Reset 8 Manual Sensor Reset 7 2 8 Subsequent Alarm Operation 9 Fire Silence Reset User Codes 9 Auto Scroll LCD Keypad Display 9 Fire Trouble Conditions 9 AC Delays 10 Bypassing Fire Zones 10 Fire Drill Feature 10 Fire Inspector Test 11 Testing AMS 220 220T Smoke Detectors 11 Lamp Test 11 PC4701 Remote Station Alarm Trouble Relays 12 Fire Reporting Codes 12 Upload Download Considerations 13 1 Introduction Introduction PC4010CF is a ULC listed combination fire burglary access control panel When used as a fire panel all functions must be configured to take priority over Access Control and other auxiliary functions PC4010CF has a number of system functions estab as default values These functions must be main to ensure the Life Safety of meets all applicable codes and standards ensure an appropriate installation all applicable and codes and standards should be Local AHJ Authority Having Jurisdiction also be consulted prior to installation to deter specific local requirements for a fire alarm installa in this manual is intended to describe the functionality of the equipment Further information the overall system is contained in the companion for this product and must be consulted for a full of operation installation and program manual lists a number of alarm initiating and alarm devices for use with this equipment Use of other than those listed herein must be carefully for compatibility 2 wire smoke detectors other those listed in this manual cannot be used without the listing status of the equipment downloading of a fire panel once it has been put operation and is protecting a premises is severely See the Upload Download section of this man for information on this topic Main Panel One PC4050CR red cabinet 14.8 x 12.0 x 4.9 with for two 12V 7Ah sealed lead acid rechargeable One PC4010 Main Control Module which includes 8 zones programmable for Fire or Burglary One Programmable Output programmable as an device loop 12 VDC 50 mA max each standard output or 12 VDC 170 mA max each addressable loops One switched AUX Power Supply 12 VDC 300 mA max One unswitched AUX Power Supply 12 VDC 500 One Supervised Bell circuit 12 VDC 700 mA max Supervised Battery Charger 12 VDC 350 mA charg current continuous 400mA max Supervised Telephone Communicator connects to module Hardware Description and Specifications One Power Transformer 16.5 VAC 40 VA One Hardware package which includes 16 EOL resistors 5,600W One Black cabinet plug One green grounding strap Mounting hardware for the PC4010A PCB The Escort4580 cannot be used with PC4010CF Fire Module One Two Wire Smoke detection zone Class Accommodates up to 30 12 VDC 2 wire smoke One Waterflow zone Class Two Supervised Communicator outputs One Fire Alarm actuated relay rated 2A 30 VDC One Fire Trouble actuated relay rated 2A 30 VDC Terminal connections for house telephone Hardware to mount the module to the sidewall of the enclosure Bell Panel One PC4052CR Red cabinet 12 x 12 x 5 with for two 12 VDC 4.0Ah sealed lead acid recharge batteries One PC4702 Dual Bell Zone module which includes Two supervised Class Bell outputs 24 FWR 1.8A each Outputs supervised for opens and ground with self restoring short protec Supervised battery charger 24 VDC 350 mA charg current for sealed lead acid rechargeable batter Power transformer 28 VAC 175 VA mounted in Combus connection terminals Hardware for mounting PC4702 module Fire Keypad LCD keypad with red bezel for use with the Fire Keypad with Function Keys keypad with red lens and five function keys Silence Trouble Silence Bells Fire Reset Fire Drill Lamp Test At least one LCD4520 or LCD4521 keypad must used with the PC4010CF Maximum keypad current draw 55mA Capacity for four PC4216 output modules for 64 Flush Trim For PC4664 0.75 2cm matching trim all round the PC4664 System Modules following modules may be added to the basic sys to expand the zone capacity and add other func PC4108A 8 zone expansion module PC4116 16 zone expansion module PC4164 RS 64 zone Wireless Receiver PC4216 16 zone Low Power output module PC4204 Power Supply and quad relay module non LCD4500 LCD Keypad non fire LCD4501 LCD Keypad with five function keys non PC4400 Printer interface and DVAC module PC4820 Dual Card Reader Access Control module LINKS1000 Cellular backup communicator panel