DSC PC4020CF v3 0 - Commercial Fire Installation Manual - English - MAXSYS 16-128 Zone Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

PC4020CF v3.0 and higher Commercial Fire Installation Guide v1.3 of Contents 1 Introduction Introduction 1 Hardware Description and Specifications 1 2 Fire Zone Types Partitions and Fire System Configuration 3 Standard Fire Zone 3 Auto Verify Fire 3 Waterflow Zone 4 Fire Supervisory Zone 4 PC4701 Zones 5 4 Wire Smoke Detector Zones 5 AMS 220 Addressable Smoke Detector Zones 5 AMP 702 Addressable Fire Point Module 5 3 PC4702BP Output Programming Alarm Notification Output Types 6 Programming PC4702BP Outputs 6 Fire Bell Options 6 Partitions and Fire System Configuration 7 4 Fire System Operation Manual Signal Silence 8 Automatic Signal Silence Bell Cut Off 8 Signal Silence Inhibit Timer Fire Silence Delay 8 Fire System Reset 8 Manual Sensor Reset 7 2 8 Subsequent Alarm Operation 9 Fire Silence Reset User Codes 9 Auto Scroll LCD Keypad Display 9 Fire Trouble Conditions 9 AC Delays 10 Bypassing Fire Zones 10 Fire Drill Feature 10 Fire Inspector Test 11 Testing AMS 220 220T Smoke Detectors 11 Lamp Test 11 PC4701 Remote Station Alarm Trouble Relays 12 Fire Reporting Codes 12 5 Listing Requirements UL Listed Commercial Burglary and Residential Installations 13 Commercial Fire Alarm Installations 13 A Wiring Diagrams PC4020CF Wiring Diagram PC4701 Wiring Diagram and 2 Wire Smoke Connection Zone Circuits 15 PC4020CF Communications Connections PC4701 PC4702BP Wiring Diagram 17 Battery Lead and AC Power Lead Routing UL Listed Commercial Fire Systems Sensor Reset for 4 Wire Smoke Detectors 18 PGM Connections 18 AMS 220 Addressable Smoke Detector Connection 18 1 Introduction Introduction Hardware Description and Specifications PC4020CF is a UL ULC listed combination fire bur and access control panel When used as a fire panel fire functions must be configured to take priority over Access Control and other auxiliary functions PC4020CF has a number of system functions estab as default values These functions must be main to ensure the Life Safety of meets all applicable codes and standards ensure an appropriate installation all applicable UL and local codes and standards should be Local AHJ Authority Having Jurisdiction also be consulted prior to installation to deter specific local requirements for a fire alarm installa in this manual is intended to describe the functionality of the equipment Further information the overall system is contained in the companion for this product and must be consulted for a full of operation installation and program manual lists a number of alarm initiating and alarm devices for use with this equipment Main Panel One PC4050CR red cabinet 14.8 x 12.0 x 4.9 with for two 12V 7Ah sealed lead acid rechargeable One PC4020 Main Control Module which includes 16 zones programmable for Fire or Burglary Two Programmable Outputs each programmable as addressable device loop 12 VDC 50 mA max each standard output or 12 VDC 170 mA max each addressable loops One switched AUX Power Supply 12 VDC 120 mA One unswitched AUX Power Supply 12 VDC 120 max Refer to the PC4020 Installation Manual for devices One Supervised Bell circuit 12 VDC 700 mA max Supervised Battery Charger 12 VDC 350 mA charg current continuous 400mA max Supervised Telephone Communicator connects to module One Power Transformer 16.5 VAC 40 VA One Hardware package which includes 16 EOL resistors 5,600 One Black cabinet plug One green grounding strap Mounting hardware for the PC4020A PCB The Escort4580 cannot be used with PC4020CF Fire Module One Two Wire Smoke detection zone Class Accommodates up to 30 12 VDC 2 wire smoke One Waterflow zone Class Two Supervised Communicator outputs One Fire Alarm actuated relay rated 2A 30 VDC One Fire Trouble actuated relay rated 2A 30 VDC Terminal connections for house telephone Hardware to mount the module to the sidewall of the enclosure Local Area Network Communicator T Link Local Area Network Communicator provides efficient method of communicating via a Local Area LAN See the T Link Installation Manual part 29001007 for more details Bell Panel One PC4052CR Red cabinet 12 x 12 x 5 with for two 12 VDC 4.0Ah sealed lead acid recharge batteries One PC4702 Dual Bell Zone module which includes Two supervised Class Bell outputs 24 FWR 1.8A each Outputs supervised for opens and ground with self restoring short protec Supervised battery charger 24 VDC 350 mA charging for sealed lead acid rechargeable batteries Power transformer 28 VAC 175 VA mounted in Combus connection terminals Hardware for mounting PC4702 module Fire Keypad LCD keypad with red bezel for use with the Fire Keypad with Function Keys keypad with red lens and five function keys Silence Trouble Silence Bells Fire Reset Fire Drill Lamp Test Flush Trim For PC4664 0.75 2cm matching trim all round the PC4664 System Modules following modules may be added to the basic system expand the zone capacity and add other functions PC4108A 8 zone expansion module PC4116 16 zone expansion module PC4164 RS 64 zone wireless receiver PC4216 16 zone low power output module PC4204 Power supply and quad relay module non LCD4500 LCD Keypad non fire LCD4501 LCD keypad with five function keys non PC4400 Printer interface and DVAC module PC4820 Dual card reader access control module LINKS1000 Cellular communicator panel LINKS2150 Long range transmitter Residential use only Burglary and residential fire only Smoke Detectors following list of 2 wire smoke detectors have been as compatible with the PC4701 Fire module two smoke detection zone DSC MN 220 Photoelectric smoke detector DSC

Related Files