DSC PC4400 v1 0 - Installation Manual - English - MAXSYS Printer Interface DVACS Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc4400-v1-0-installation-manual-english-maxsys-printer-interface-dvacs-module-5173946208.pdf |
---|---|
Type | |
Size | 786.64 KB |
Downloads |
Text Preview
3 of Contents 1 1 connected to a serial printer 1 connected to a DVAC network 1 the PC4400 1 1 Mounting the Cabinet 1 Wiring 1 Hookup Diagram 2 Power 2 the Module 3 the Module 3 Rate 3 Options 3 Identifiers 3 DVAC 6 Conditions 6 Worksheets 7 Rate 7 Options 7 DVAC Programming 7 Identifiers 8 X Alarm Restore 8 Identifiers 9 X Trouble Restore 9 X Fault Restore 10 Tamper Restore 11 Alarms 11 and Closings by User 12 Openings and Closings 13 Openings and Closings 13 Maintenance 13 Troubles 13 Module 13 Low Batter 14 Low Battery 14 Code PC 14 Module 14 Identifiers 15 Bytes 15 Function Bytes 15 Function Bytes 15 Function Bytes 16 Function Bytes 16 and Closing Function Bytes 16 Function Bytes 17 Specific Message Function Byte 17 I n t r o d u c t i o n PC4400 module adds serial printer or DVAC com capability to a MAXSYS PC4010 or PC4020 system Four wire QUAD hook up to Combus Normal current draw of 35 mA Tamper and Trouble reporting codes Low Combus supervision to Main Control Panel Maximum cable length 200 feet 61 meters connected to a serial printer True RS 232 technology Protocol XON XOFF or DTR Five possible baud rates 300 600 1200 2400 or 4800 4800 Baud only available on PC4010 PC4020 and above connected to a DVAC network Automatic programming for DVAC function bytes and codes Programmable response type to all calls Monitoring for DVAC Line fault Module self diagnostics the PC4400 PC4400 package includes the following parts One PC4400 circuit board Four plastic stand offs Mounting the Cabinet mounting a new cabinet for the PC4400 select a location close to either the serial printer or the F1 F2 if DVAC communication is to be used mount the cabinet From the back of the cabinet press in the four white board stand offs into the raised mounting Holding the cabinet in position pull all wiring into cabinet through the hole in the back Using the provided mounting screws and appropri wall anchors mount the cabinet securely to the Press the PC4400 module onto the plastic stand offs Wiring beginning to wire the unit ensure that all power transformer and battery is disconnected from the panel the following steps to complete wiring Connect the four Combus wires to the PC4400 Con the red black yellow and green Combus wires the RED BLK YEL and GRN terminals respec Connect terminals T1 and T2 to a normally closed switch If no tamper switch is desired con a jumper wire between T1 and T2 terminals the wiring diagram on page 2 for further infor Hookup Diagram Applying Power all wiring is completed apply power to the control panel Connect the battery leads to the battery then connect the AC For more information on control panel power specifications see the control panel Installation Manual Do not connect the power until all wiring is complete the Module all wiring is complete you must enroll the module Enter installer programming by pressing 8 Code Scroll to Hardware and press the key Scroll to Module and press the key Scroll through the different modules until displayed Press the key The message Tamper on Desired Unit will displayed To create the required tamper secure tamper zone on the module and then open it The from secure to violated enrolls the module this is done the keypad will display the mod number and will confirm enrollment e g Mod 01 Enrolled The panel will prompt Toggle DVAC N To enable the module for DVAC commu press The display changes to Y To use the module with a serial printer the toggle set to enabled N To change the DVAC enabled toggle option for module you must remove and then re enroll the more information regarding module enrollment see control panel Installation Manual the Module access PC4010 PC4020 programming enter 8 fol by the Installer code The sections you will need program are described below For more information programming see the control panel Installa Manual PC4400 module programming sections are located in System Area section under the PC4400 options Once have entered installer programming enter the reference number on PC4010 PC4020 v3 x only OR use the keys to scroll through the options on the LCD display and press select the desired option following explains each programming option rele to the PC4400 Rate 000800 section is used to program which baud rate the serial interface module will use to communicate a serial printer The baud rate is the speed at which will be transmitted from the PC4400 module the serial printer There are five different baud rates to the PC4400 module 300 600 1200 2400 and baud If you are experiencing problems with miss characters try lowering the baud rate 4800 Baud only available on PC4010 PC4020 and above DVAC Options 00080100 section is used to program DVAC options for the module This section is only available if the PC4400 is enrolled as a DVAC module E n r o l n g t h e M o d u l e Code Option is the ID code the PC4400 module will use for communications Valid ID codes range from 01 to The default ID code is FF With this setting the will respond to ID code 01 Do not plug the DVAC line into the module the ID code has been programmed Call Select Options option determines how the PC4400 module will to all calls from the central station The valid are from 00 to 04 No response on all calls Respond to all call 1 only Respond to all call 2 only Respond to both all calls Respond to all call 1 if ID code is odd or on all call if ID code is even default all call setting is FF With this setting the will follow the all call option 04 DVAC Identifiers 00080101 section is used to program