DSC PC4612(A) v1 0 - Installation Manual - English - MAXSYS Fire 12-Zone Annunciator

File Preview
File Preview
Click below to download for free

Text Preview

PC4612 A Zone Annunciator Instructions Introduction PC4612 A is a 12 zone annunciator for use with PC4010 PC4020 systems You can install a combined total of 9 PC4612 A and modules on each PC4010 4020 system Specifications Style PC4612 or PC4612A available 16 programmable LEDs Four wire QUAD hook up to Combus Nominal current draw of 15mA Tamper and trouble reporting Supervision by control panel via Combus Installation the PC4612 A to the panel via the Combus Be sure to in the current draw of the PC4612 A 15mA in your Combus cur calculation Refer to your PC4010 4020 Installation Manual for information on Combus wiring Enrolling and Programming the PC4612 A the instructions below for enrolling and programming your module If you are enrolling the module on a PC4010 4020 or greater system you can use the reference numbers indicated the square brackets eg 0200 to jump to a programming section to your system installation or programming manual for more on programming Enrolling must enroll the PC4612 A module with your panel before you program it The PC4612 A is enrolled exactly as if it were a module Follow these steps At a PC4010 4020 system LCD keypad enter Installer Program 8 Installer code Enter Ref 0200 OR scroll to Module Hardware press scroll to Enroll Module press Scroll to PC4216 Module press The LCD keypad displays Tamper on Desired Unit Tamper and then restore the PC4612 A Remove the screws on the bottom of the unit Pull the front plastic of the unit approximately away from backplate Replace the front of the unit and the screws in their original The LCD keypad displays PC4216 Mod 01 Enrolled Record the module number in the worksheet area on the back of instruction sheet To exit Module Enrollment press Programming the PC4612 A each of the 16 outputs controls a particular LED Out 1 12 control the LEDs which light up numbers 1 12 on the Annun Outputs 13 16 control the LEDs which light up the Zone Trouble Trouble System Trouble and AC On indicators respectively Custom Group is a set of 16 programming choices which correspond the 16 programmable outputs on each PC4612 A module Each will function according to the programming of its output in the custom group program the PC4612 A you need to assign a custom group to the and to make sure that the outputs of the assigned custom are programmed appropriately Example the PC4612 A is as to custom group 01 In this custom group output 05 is pro to follow zone which is a fire zone This was done by programming output 05 option 22 zone follow When zone 020 is in alarm LED 5 turns When zone 020 is restored and a fire reset is performed LED 5 off PC4612 A uses the same programming as the PC4216 and is done in the same programming sections These sections are below as they relate to the PC4612 A For instructions on to program the PC4010 4020 and its modules refer to your Installation Manual For information on programming modules refer to your PC4216 Installation Instructions Choose a Custom Group 000703XX where XX 01 09 PC4612 A number Program PC4612 A to use one of nine custom groups More than one mod may follow the same custom group Enter the number of the custom the PC4612 A will follow enter 01 09 To exit press Program a Custom Group 000704XX where XX 01 09 Custom Group 01 09 A cus group is a set of 16 programmed output options Each output in a group can be programmed to operate according to a different option Choose the output to be programmed 01 16 Enter the number of the output option to be used for that output To exit press refer to the System Installation Manual for information on limitations regarding product use function and information on the limitations as to liability of the manufacturer recommended output options for the PC4612 A are 21 22 55 56 57 Their descriptions are listed below Recommended Output Options Alarm 21 zones that are programmed as burglary the zone alarm output will the LED when the selected burglary zone has gone into LED will remain on until the partition is armed again Follow 22 zones that are programmed as Fire or Fire Supervisory the zone output will turn on the LED when the fire zone is in alarm or the fire supervisory zone is off normal zone shorted The LED only turn off when the zone has been restored and a fire reset has performed 1 10 have red LEDs and are intended for fire burglary alarm annunciation Outputs 11 12 have yellow LEDs and are intended fire supervisory zone annunciation Use Options 21 or 22 for output numbers 01 10 and option 22 for output numbers 11 12 Zone Tbl 48 output will activate when a fire zone is bypassed or when a fire trouble condition is detected The output will deactivate when the is unbypassed or the trouble is restored Use this option for output number 13 Fire Tbl 55 output activates when any of the following troubles are detected the panel The output deactivates when the trouble is cleared Any system AC or battery trouble PC4020 PC4820 PC4204 Any system communicator trouble TLM1 TLM2 FTC LINKS Ground Fault trouble Use this option for PC4612 A output number 15 Trouble 56 output activates for a trouble open or short on any supervised bell output PC4010 4020 or PC4702 The output deactivates the trouble is cleared Use this option for PC4612 A output 14 Status 57 output will be ON when AC power is present on the PC4010 as well as all enrolled modules PC4204 PC4820 PC4702 If PC4010 4020 or any module loses AC power the AC Fail Delay will start see your PC4010 4020 Installation Manual for more When the timer expires or if it is programmed to be 0 the AC is still missing the output will turn OFF An AC Fail trouble will be generated When AC power is restored the output again wait for the AC Fail Delay timer to expire If the AC power still on at the end of the delay the output will turn ON Use this op for PC4612 A output number 16 Finishing sure you label each of the 12 zone lights in the space provided the annunciator When you have finished installing and program the PC4612 A instruct the end user of the system how to inter events using the annunciator Programming Module No l l l Options PC4216 Custom Group No l l module Enter 01 09 custom group Enter 01 09 YY output Enter 01 16 LED Zone or 22 or 22 or 22 or 22 or 22 or 22 or 22 or 22 or 22 or 22 Fire Supervisory Trouble Trouble Trouble On l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 l l zone 001 128 PC4020 001 064 PC4010 Digital Security Controls Ltd Canada www dsc com Support 1 800 387 3630 Canada US or 905 760 3036 in Canada 29002625 Rev 003 all comments concerning this publication to pubs dscltd com

Related Files