DSC PC4612 v1 0 - Installation Manual - English - MAXSYS Fire 12-Zone Annunciator

File Preview
File Preview
Click below to download for free

Text Preview

1 PC4612 is a 12 zone fire annunciator for use with security systems You can install a total of 9 PC4612 and PC4216 modules on each system 16 programmable LEDs Four wire QUAD hook up to Combus Nominal current draw of 15mA Tamper and Trouble Reporting Supervision by control panel via Combus the PC4612 to the panel via the Combus Be sure include the current draw of the PC4612 15mA in your current calculation Refer to your PC4010 4020 Manual for more information on Combus and Programming the PC4612 the instructions below for enrolling and your PC4612 module If you are enrolling module on a PC4010 4020 v3.0 or greater system you use the reference numbers indicated by the square eg 0200 to jump to a programming section to your system installation or programming manual more information on programming Enrolling must enroll the PC4612 module with your panel before can program it The PC4612 is enrolled exactly as if it a PC4216 module Follow these steps At a PC4010 4020 system LCD keypad enter Programming 8 Installer code Enter Ref 0200 OR scroll to Module Hardware then scroll to Enroll Module press to PC4216 Module press The LCD keypad Create Tamper on Desired Unit Tamper and then restore the PC4612 Remove the screws on the bottom of the unit Pull the front plastic of the unit approximately from the backplate Replace the front of the unit and the screws in their locations LCD keypad displays PC4216 Mod 01 Record the module number in the worksheet area on back of this instruction sheet To exit Module Enrollment press Programming the PC4612 each of the 16 outputs controls a particular Outputs 1 12 control the LEDs which light up 1 12 on the Annunciator Outputs 13 16 control LEDs which light up the Zone Trouble Bell Trouble Trouble and AC On indicators respectively Custom Group is a set of 16 programming choices which to the 16 programmable outputs on each PC4612 Fire Zone Annunciator Instructions Each LED will function according to the of its output in the assigned custom group program the PC4612 you need to assign a custom group the module and to make sure that the outputs of the custom group are programmed appropriately the PC4612 is assigned to custom group 01 In custom group output 05 is programmed to follow 020 which is a fire zone This was done by output 05 for option 22 zone follow When 020 is in alarm LED 5 turns on When zone 020 is and a fire reset is performed LED 5 turns off PC4612 uses the same programming as the PC4216 and therefore done in the same programming sections These are described below as they relate to the PC4612 instructions on how to program the PC4010 4020 and modules refer to your PC4010 4020 Installation Manual information on programming PC4216 modules refer to PC4216 Installation Instructions Choose a Custom Group 000703XX where XX 01 09 PC4612 number each PC4612 to use one of nine custom groups than one module may follow the same custom group the number of the custom group the PC4612 will enter 01 09 To exit press Program a Custom Group 000704XX where XX 01 09 Custom Group 01 09 custom group is a set of 16 programmed output options output in a custom group can be programmed to according to a different output option Choose the output to be programmed 01 16 Enter the number of the output option to be used for output To exit press refer to the System Installation Manual for information on limitations regarding product and function and information on the limitations as to liability of the manufacturer recommended output options for the PC4612 are 22 55 56 57 Their descriptions are listed below Recommended Output Options Follow 22 zones that are programmed as Fire or Fire Supervisory zone follow output will turn on the LED when the fire is in alarm or when the fire supervisory zone is off zone shorted The LED will only turn off when zone has been restored and a fire reset has been Use this option for PC4612 output numbers 01 1 10 have red LEDs and are intended for fire alarm annunciation Outputs 11 12 have yellow LEDs and intended for fire supervisory zone annunciation only the red LEDs for fire alarms and only the yellow for fire supervisory This annunciator is intended for related outputs only Do not use the module for other of system annunciation Zone Tbl 48 output will activate when a fire zone is bypassed or a fire zone trouble condition is detected The output deactivate when the zone is unbypassed or the trouble restored Use this option for PC4612 output number 13 Fire Tbl 55 output activates when any of the following troubles detected by the panel The output deactivates when the is cleared Any system AC or battery trouble PC4020 PC4820 Any system communicator trouble TLM1 TLM2 PC4701 LINKS Ground Fault trouble this option for PC4612 output number 15 Trouble 56 output activates for a trouble open or short on any system bell output PC4010 4020 or PC4702 output deactivates when the trouble is cleared Use this for PC4612 output number 14 Status 57 output will be ON when AC power is present on the as well as all enrolled modules PC4204 PC4702 If the PC4010 4020 or any module loses power the AC Fail Delay timer will start see your PC4010 Installation Manual for more information When the expires or if it is programmed to be 0 if the AC is still the output will turn OFF An AC Fail trouble condition be generated When AC power is restored the output again wait for the AC Fail Delay timer to expire If the AC is still on at the end of the delay the output will turn Use this option for PC4612 output number 16 Finishing sure you label each of the 12 zone lights in the space on the annunciator When you have finished and programming the PC4612 instruct the end user the system how to interpret events using the annunciator Programming Options Module No l l l XX module Enter 01 09 Group No Custom XX custom group Enter 01 09 YY output Enter 01 16 Zones Fire Supervisory Yellow Trouble Trouble Trouble On Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Zone 001 128 PC4020 001 064 PC4010 Products Digital Security Controls Ltd Flint Road Downsview Ontario Canada M3J 2J6 665 8460 Fax 416 665 7498 1 800 387 3630 in Canada 29002625 R0

Related Files