DSC PC4701 Fire Expansion Module

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc4701-fire-expansion-module-6317948502.pdf
Type PDF
Size 823.68 KB
Downloads

Text Preview

PC4701 Fire Expansion Module Instructions PC4701 is a fire expansion module for use with PC4010CF Maxsys security systems One module may be per system The PC4701 cannot be used on a Maxsys system if an is also connected Connects to control panel via 4 wire Combus Current Draw 40 mA from Combus Class B Style B 2 Wire Smoke Detector Supervision Operating Voltage Range 8.9 12.0 VDC Maximum Alarm Current 80mA Maximum Ripple 0.5 VP P Compatibility Identifier FM1 Maximum line resistance 50W Class B Style B Waterflow Supervision Supervised Dual Telephone Lines Service Type Automatic Manual Sprinkler Supervisory the PC4701 Signaling Type Non Coded Unpacking PC4701 package includes the following parts One PC4701 circuit board 2 listed end of line resistors 2200 ohms Four plastic stand offs Mounting the PC4701 on either side wall of the PC4010CF cabinet mounted in a dry secure location the following steps to mount the unit Press the four plastic stand offs through the mounting holes the side wall of the cabinet Secure the cabinet to the wall in the desired location Use wall anchors when securing the cabinet to drywall concrete brick or other surfaces Press the circuit board into the plastic stand offs to secure the to the cabinet the unit is mounted complete the wiring Wiring beginning to wire the unit ensure that all power AC and battery is disconnected from the control panel the following steps to complete wiring Connect the four Combus wires to the PC4701 Connect the black yellow and green Combus wires to the RED BLK and GRN terminals respectively Complete all other wiring according to the wiring diagrams Fire Trouble Contact the Common Fire Trouble Contact is connected the output will when any of the following troubles occur Fire Zone Trouble Any Bell Trouble Any AC Trouble Any Battery Trouble Ground Fault Trouble Communication Troubles output will deactivate when all trouble conditions are Refer to the PC4010 PC4020CF Installation Guide for information on these trouble conditions Fire Alarm Contact the Common Fire Alarm Contact is connected the output will when an alarm occurs on any fire zone The output will when all fire zones have been successfully reset Line Switching the PC4701 detects a TLM trouble on either telephone line will automatically use the other telephone line if a needs to be sent If there are no TLM troubles PC4701 will use telephone line 1 leaving telephone line 2 for the premises telephones Applying Power all wiring is completed apply power to the control panel the battery leads to the battery then connect the AC For more information on control panel power see the control panel Installation Manual Do not connect the power until all wiring is complete all wiring is complete the module must be enrolled on the To enroll the module perform the following Enter installer programming by pressing 8 Installer the Module Scroll to Hardware and press the key Scroll to Module and press the key Scroll through the different modules until Fire is Press the key After this is done the keypad the module number and confirms enrollment e g Fire Mod 01 Enrolled refer to the System Installation Manual for information on limitations regarding product use function and information on the limitations as to liability of the manufacturer the Module more information regarding module enrollment see the panel Installation Manual access PC4010 PC4020 programming enter 8 followed the Installer code Program the sections indicated on this and record your programming choices in the space The waterflow and 2 wire smoke zones are hard coded the zone type cannot be changed Refer to your Commercial Installation Guide for more information on PC4701 zones the 2 wire smoke auto verify feature is enabled in the System section ref 000200 the panel will automatically alarms from the 2 wire smoke circuit of the PC4701 before the bells and transmitting the alarms will function as follows when the 2 wire smoke is shorted the PC4701 performs a sensor reset by removing from the circuit for 20 seconds After the 20 second reset will be restored to the circuit and troubles will be bypassed 10 seconds to allow detectors to settle If the smoke detectors another alarm within 60 seconds after power is restored fire alarm will be generated immediately If the smoke detector not reset by the power down the zone will not be restored If occurs the panel will initiate a fiire alarm immediately 30 after initial alarm the feature is disabled the panel will generate fire alarms refer to your PC4010 PC4020 Installation Manual for information on how to program Messages Smoke I I I I I I I I I I I I I I I I I Toggle Options scroll to 2WS AutoVerify Default N Waterflow Delay If a waterflow delay is programmed the PC4701 waterflow zone follows it Please see your PC4010CF 4020CF Installation for more details entries are 000 090 seconds 000 Codes Events Wire Alarm Wire Restore Wire Trouble Test Begin Wire TBL Rest Alarm I I I TBL Rest TBL Rest I I I Unbypass Test End Bypass CANADA NOTICE The Industry Canada label identifies certified equipment This certification that the equipment meets certain telecommunications network protective operational safety requirements Industry Canada does not guarantee the equipment will operate to user satisfaction installing this equipment users should ensure that it is permissible to be connected the facilities of the local telecommunications company The equipment must also be using an acceptable method of connection The customer should be aware that with the above conditions may not prevent degradation of service in some to certified equipment should be made by an authorized Canadian maintenance designated by the supplier Any repairs or alterations made by the user to this or equipment malfunctions may give the telecommunications company cause request the user to disconnect the equipment should ensure for their own protection that the electrical ground connections of the utility telephone lines and internal metallic water pipe system if present are together This precaution may be particularly important in rural areas Users should not attempt to make such connections themselves but should the appropriate electric inspection authority or electrician as appropriate The Ringer Equivalence Number REN assigned to each terminal device an indication of the maximum number of terminals allowed to be connected to telephone interface The termination on an interface may consist of any combination of subject only to the requirement that the sum of the Ringer Equivalence Number all the devices does not exceed 5 REN of this unit is 0.0 the separation between the equipment and receiver COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Ltd could void your authority to use this equipment equipment has been tested and found to comply with the limits for a Class B device pursuant to Part 15 of the FCC Rules These limits are designed to reasonable protection against harmful interference in a residential installation equipment generates uses and can radiate radio frequency energy and if not and used in accordance with the instructions may cause harmful interference radio communications However there is no guarantee that interference will not in a particular installation If this equipment does cause harmful interference radio or television reception

Related Files