DSC PC5010 v1 0 - Installation Manual - English - PowerSeries 8-32 Zone Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

System Introduction Panel Specifications Zone Configuration 8 Fully Programmable Zones 37 Access Codes 32 User 1 System Master 2 Partition Master and 2 Duress Expandable to 32 Zones Hardwired expansion available using the PC5108 Eight Zone Expansion Module Wireless expansion available using the PC5132 Wireless Zone Expansion Module up to 32 wireless 900 MHz True Spread Spectrum Technology Fully Supervised Normally Closed Single EOL Double EOL or Zone Doubler zone supervision 2 Wire Smoke Zone 27 Zone Types 7 Programmable Zone Options 2 Partitions Alarm Output Supervised Bell Output current limited at 3 amps 12 VDC Steady or Pulsed Output Memory Will not lose programming or system status on complete AC and Battery failure Outputs Up to 14 Programmable Voltage Outputs 14 programmable options One High Current 300 mA PGM output with 2 wire smoke detector capability on main panel One Low Current 50 mA PGM output on main panel Eight Additional Low Current 50 mA PGM outputs available using the PC5208 module Four High Current 1 Amp PGM outputs Available Using the PC5204 module 1 PC5204 Output Fully Supervised for Siren Output 1 Amp Regulated Power Supply 500 mA Auxiliary Supply 12 VDC Positive Temperature Coefficient PTC components replace fuses Supervision for loss of AC Power Low Battery Internal Clock Locked to AC Power Frequency Requirements Transformer 16.5 VAC 40VA Battery 12 volt 4 Ah minimum rechargeable sealed lead acid Keypad Specifications 4 Different Keypads Available PC5508 8 Zone LED Keypad PC5532 32 Zone LED Keypad PC5516 16 Zone LED Keypad LCD5500 Alphanumeric Keypad Each Keypad has 5 Fully Programmable Function Keys Connect up to 8 Keypads Four Wire Quad Connection to Keybus Built in Piezoelectric Buzzer Communicator Specifications Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 3 Programmable Phone Numbers 2 Account numbers Supports LINKS1000 Cellular Communication DTMF and Pulse Dialling DPDT Line Seizure Anti jam Feature Split Reporting of Selected Transmissions to Each Telephone Number Supervision Features PC5010 continuously monitors a number of possible trouble conditions including AC Power Failure Fire Trouble Low Battery Condition Loss of Internal Clock Tamper by Zone Module Fault Supervisory or Tamper Trouble by Zone Telephone Line Trouble Bell Output Trouble AUX Power Supply Fault Failure to Communicate Alarm Prevention Features Audible Exit Delay Urgency on Entry Delay Swinger Shutdown Communication Delay Features Auto Arm by Partition at Specified Time Keypad Activated Alarm Output and Communicator Test Keypad Lockout Audio Capability using the PC5928 Audio Interface Module which allows local intercom and Central Audible Exit Fault Quick Exit Recent Closing Transmission 2 Way Listen in All modules connect to the system via a four wire Keybus up to 1000 from main panel Event Buffer can be printed using PC5400 RS232 Serial Interface module Zone Doubler Option Supports the Escort5580 Voice Prompt Module with Automation Lighting Control 128 Event Buffer Time and Date Stamped Upload Download Capability Devices maximum of eight 8 keypads can be connected to the control panel and can be any combination of the listed Different keypads with function keys can be used for different size systems 8 zone 16 and 32 zone zone LED keypad zone LED keypad zone LED keypad keypad Eight Zone Expander Module zone expander module can be used to increase the number of zones on system Up to 3 modules can be connected to increase the system zones to maximum of 32 See PC5108 Installation Instructions Sheet Zone Doubler Expander Module PC5108D provides an additional 16 zones when the Zone Doubler option is utilized Only one module can be added to the system to expand the to the maximum of 32 zones See PC5108D Installation Instructions Wireless Receiver Module PC5132 Wireless Receiver module can be used to connect up to 32 devices All devices are spread spectrum 900 MHz fully supervised use standard or alkaline batteries See Section 5.27 See PC5132 Installation Manual wireless devices are available Wireless Motion Detector wireless Motion Detector can be used in conjunction with the PC5132 Wireless Receiver to include space protection The unit comes with four batteries Wireless Smoke Detector wireless Smoke Detector can be used in conjunction with the PC5132 Wireless Receiver to include smoke detection The unit comes with six batteries Wireless Slimline Universal Transmitter wireless Slimline Universal Transmitter can be used with the PC5132 Wireless Receiver to add door or window contacts in a smaller package The unit comes with three batteries and has contacts Wireless Panic Pendant wireless Panic Pendant can be used in conjunction with the PC5132 Wireless Receiver to include wireless protection The unit comes with 1 mini 12V battery is a disposable transmitter in that it is Ultrasonically welded together and the battery is not user Wireless Key Wireless Key can be used in conjunction with the PC5132 Wireless Receiver to include a simple and method of arming and disarming the system The unit comes with three Photo Electronic 1.5V batteries system can have a maximum of 16 Wireless Keys Wireless Handheld Keypad wireless Handheld Keypad can be used in conjunction with the PC5132 Wireless Receiver to include a and mobile method of arming and disarming the system The unit comes with three batteries system can have a maximum of four wireless Handheld Keypads Power Supply Output Module PC5204 can provide up to 1 Amp of additional power for modules or connected to the control panel The module requires a 16.5 volt AC 40 transformer and 4 AH battery In addition the module provides 4 program high current voltage outputs Each output is individually programmable 14 different output options available See Section 5.10 Outputs PC5204 Installation Instructions Sheet Eight Low Current Output Module eight low current outputs 50 mA to the control Each output is individu programmable with 14 different output options available See Section 5.10 Outputs See PC5208 Installation Instructions Sheet Module Escort5580 module will turn any touch tone phone into a fully functional The module also includes a built in interface to control up to 32 line type devices for lighting and temperature control See Section 5.28 Module See Escort5580 Installation Manual Audio Interface Module PC5928 Audio Interface module is a simple way to incorporate paging baby listen in and door answer to the PC5010 control panel The also has built in two way voice capability for central station See 5.30 Interface Module addtional devices are available Intercom Audio Station PC5921 Intercom Audio Station can be used in conjunction the PC5928 Audio Interface Module EXT Door Box Audio Station PC5921 EXT Door Box Audio Station can be used in with the PC5928 Audio Interface Module EXT R Door Box Audio Station PC5921 EXT R Door Box Audio Station can be used in with the PC5928 Audio Interface Module The Door contains a relay so the normal door bell can be used of the internal one generated by the PC5928 module PC5400 Printer Module

Related Files