Zone Assignment Zone 1 16 Assignment Del Zone 17 32 Assignment Del Programming Keypad Assignment Section 2.6 Assignment This must be done at each keypad requiring programming Partition and Slot Valid entries are 0 Global 1 and 2 for the Partition and 1 8 for the Slot Function Key 1 Assignment Valid entries are 00 18 Function Key 2 Assignment Valid entries are 00 18 Function Key 3 Assignment Valid entries are 00 18 Function Key 4 Assignment Valid entries are 00 18 Function Key 5 Assignment Valid entries are 00 18 Null Key Not Used Select Partition 1 Select Partition 2 Stay Arm Away Arm Q 9 No Entry Arm Q 4 Chime On Off Q 6 System Test Q 1 Bypass Mode Q 2 Trouble Display Q 3 Alarm Memory Q 5 User Programming Q 6 User Functions Q 7 1 Utility Output Q 7 2 Sensor Reset General Voice Prompt Help Q 0 Quick Exit Q 1 Reactivate Stay Away Identified Voice prompt Help Defaults Defaults 1 2 3 4 5 6 7 8 and Address 1 2 3 4 5 System Programming Definitions Null Zone Not Used Delay 1 Delay 2 Instant Interior Interior Stay Away Delay Stay Away Delayed 24 Hour Fire Hardwired Standard 24 Hour Fire Hardwired 24 Hour Supervisory LINKS 24 Hour Supervisory Buzzer 24 Hour Burglary 24 Hour Holdup 24 Hour Gas 24 Hour Heat 24 Hour Medical 24 Hour Panic 24 Hour Emergency 24 Hour Sprinkler 24 Hour Water 24 Hour Freeze 24 Hour Latching Tamper Momentary Keyswitch Arm Maintained Keyswitch Arm LINKS Answer Delay 24 Hour Fire Wireless Standard 24 Hour Fire Wireless Zone 1 8 Definitions Section 5.1 Definitions Zone 9 16 Definitions Section 5.1 Definitions Zone 17 24 Definitions Section 5.1 Definitions Zone 25 32 Definitions Section 5.1 Definitions Zone 5 Zone 6 Zone 7 Zone 8 Zone 13 Zone 14 Zone 15 Zone 16 Zone 21 Zone 22 Zone 23 Zone 24 Zone 29 Zone 30 Zone 31 Zone 32 Zone 1 Zone 2 Zone 3 Zone 4 Zone 9 Zone 10 Zone 11 Zone 12 Zone 17 Zone 18 Zone 19 Zone 20 Zone 25 Zone 26 Zone 27 Zone 28 System Times Delay 1 in seconds Delay 2 in seconds Delay in seconds Cut off in minutes Installer Code Section 4.1 to Enter Installer Programming Master Code Section 3.1 Codes Maintenance Code Section 3.1 Codes Output Options Not used Burglary and Fire Bell Output Utility Output Sensor Reset 2 Wire Smoke Support PGM2 ONLY System Partition Armed Status Ready To Arm Keypad Buzzer Follow Mode Courtesy Pulse System Trouble Output with Trouble options Latched System Event Strobe with Event options System Tamper all sources zones kpd modules TLM and Alarm Kissoff Output Ground Start Pulse For Future Use LINKS 1000 Support PGM 1 only Away Arm Stay Arm PC5010 PGM Output Programming PGM 1 2 Section 5.10 Outputs PC5208 PGM Output Programming PGM 3 10 Section 5.10 Outputs PGM 7 PGM 8 PGM 9 PGM 10 PC5204 PGM Output Programming PGM 11 14 Section 5.10 Outputs PGM 1 PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 11 PGM 12 PGM 13 PGM 14 Keypad Lockout Options Section 5.22 Lockout of Invalid Codes Before Lockout Duration in minutes First System Option Code Closed Loops End of Line Resistors Zones 1 4 enabled Zones 5 8 enabled 8 is Fast Loop Response Future Use Buffer Follows Swinger Shutdown Future Use Resistors uuuuu End of Line Resistors Zones 1 4 disabled Zones 5 8 disabled 8 is Standard Loop Response Buffer Logs Events Past shutdown Second System Option Code Third System Option Code Disarm Bell Squawk enabled iiiii Arm Disarm Bell Squawk disabled Squawk During Auto Arm Squawk On Exit Delay Squawk On Entry Delay Squawk On Trouble Exit Beeps Delay Termination Enabled Bell is continuous Bell Squawk During Auto Arm Bell Squawk On Exit Delay Bell Squawk On Entry Delay Bell Squawk On Trouble Exit Delay Delay Termination Disabled Bell follows Bell Cut off Keys Enabled Keys Audible Bell Beeps Exit Enabled Arming Enabled Require

Related Files