DSC PC5010 v3 2 CP-01 - Installation Manual - English - PowerSeries 8-32 Zone Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

This manual contains information on limitations regarding product use and function and information on the as to liability of the manufacturer The entire manual should be carefully read classified in accordance with ANSI SIA CP 01 2000 SIA FAR Manual CP 01 CP 01 Version 3.2 and higher Features Support Activity Arming Partition Pre Alert Test Zoning Automatic ID Buzzer PC5010 CP 01 v3.1 and higher supports the new PC5200 Power Supply module See PC5200 Power Supply Module Pg 2 Support PC5010 CP 01 v3.1 and higher supports the PC5936 15 station audio matrix module See PC5936 Audio Inter Module Pg 3 FAR False Alarm Reduction has been incorporated in this version See the Quick Reference Chart SIA FAR on the fol page feature enables the system or partition to arm if there is no zone activity for a programmed time period See 191 192 No Activity Timer Partition 1 2 Auto arm Pre alert Time is now programmable The default value for this timer has been extended to 5 minutes Section 199 Auto arming Pre Alert Time Pg 30 this feature enabled the panel will not send a test transmission if there has been any transmission received by receiver within the programmed time See Section 018 Sixth System Option Codes Option 1 Pg 27 feature requires two or more trips on a zone s specified as zones within a specified time before starting alarm sequence The Cross Zone option is programmable by zone via Attribute 9 See Section 018 Sixth Sys Option Codes Option 6 Pg 28 selecting Automatic Contact ID for reporting the reporting code will represent how a zone is defined according the SIA specification for Contact ID If Automatic Contact ID is enabled see Appendix A for reporting codes that be used for each zone type enabled and the system or Partition is in alarm all assigned keypad buzzers will follow the bell output When the keypad buzzers will only sound for buzzer type alarms This option is off at default See Section 018 System Option Codes Option 5 Pg 28 Zone Types Sections 001 002 Zone Definitions Pg 21 Type 27 Delayed 24 Hour Waterflow Zone Type 28 Instant 24 Hour Waterflow Zone Type 29 Auto Verified Fire Zone Type 30 Fire Supervisory Zone Type 31 Day Zone Silence Option Door Chime Verbal Alarm Response option affects the Instant Waterflow Zone and the Delay Waterflow Zone option does NOT allow the user to silence alarms manually automatically or by a system reset until all waterflow are returned to their restored state See Section 018 Sixth System Option Codes Option 4 Pg 28 feature enables the Door Chime to verbally annunciate the Zone that has been violated instead of a series of See Section 018 Sixth System Option Codes Option 2 3 Pg 33 This feature is only available when using ESCORT5580 v3.0 and the PC5936 v1.0 Refer to the Escort5580 v3.0 and PC5936 v1.0 Installation Manuals further information PC5010 CP 01 v3.1 and higher can configure any or all onboard zones for 36 ms Loop Response see Section Fast Loop Response Pg 29 PC5010 CP 01 v3.2 supports the T Link TCP IP Network Communicator CP 01 Installer Programming Quick Reference Chart SIA False Alarm Reduction requirement system for SIA FAR Installations 1 PC5010 CP 01 Control Panel 2 Local Annunciation Devices local annunciation devices may be any combination of the following keypads LCD5500Z LCD5520Z PKP LCD following optional subassembly modules also bear the SIA FAR classification may be used if desired Zone Expander Module initiating devices Bravo200 series 300 series 400 series 500 series series AC 100 Encore300 series Force200 series 210 series MN240 Low Current PGM Output Module following optional accessory modules also bear the SIA FAR classification and be used if desired Auxiliary Power Supply with PGM output ports Printer Module Number Section 1st and 2nd Entries Test End and Begin Reporting Codes Access to the reporting codes for Walk Test Begin and Walk Test End Times Access to Entry Delays and Exit Delay for each partition and Bell Time Out for the system Outputs Access to PGM Output programming for the main board PC5208 and PC5204 modules Output in Section in Sections 501 514 Partition Assignments in Section 551 532 Exit Beeps Enables beeps from the keypad for the duration of Exit Delay Zoning This option enables Cross Zoning for the entire system Individual zones can be enabled for Cross zoning Zone Attributes in Sections 101 132 Default OFF Delay Restart Enables the Exit Delay Restart feature Attributes Access to zone attributes such as Audible Bell Swinger Shutdown Transmission Delay and Cross Zone Zone Timer Access to the programmable Cross Zone timer Waiting Cancel Dialing String Access to the Dialing sequence used to disable Call Waiting Zone Reporting Code Access to the reporting code for Cross Zone Alarm not Verified Reporting Code Access to the reporting code for Burglary Not Verified Cancelled Reporting Code Access to the reporting code for Alarm Cancelled Shutdown for Alarms Access to the Swinger Shutdown limit for zone alarms Delay Access to the programmable delay before communicating alarms Cancel Window Access to the programmable Communications Cancel window Comms During Walk Test Enables Communication of zone alarms while installer Walk Test is active Cancelled Message Enables the Cancelled message display on all keypads Waiting Cancel Enables the use of the Call Waiting Cancel string in programmed in Section 304 Walk Test Mode Enable Disable Installer Walk Test mode This mode can be used to test each zone on the sys for proper functionality Code Do not derive code from an existing Master User code eg Master Code is 1234 the duress code should be 1233 or 1235 Test The system activates all keypad sounders bells or sirens for 2 seconds and all keypad lights turn on Refer the User Manual part no 29005909 011 Option 6 Option 6 Option 7 132 6th Entry 7th Entry 8th Entry 1st Entry 4th Entry 11th Entry Option 2 Option 3 Option 4 Master Code and 34th Entries Master Code 4 this page For SIA FAR installations only use modules devices that are listed Fire Alarm Verification feature Auto Verified Fire zone is not sup on 2 wire smoke detectors zones This feature may be for 4 wire smoke detectors only Call Waiting Cancel Section 382 Option 4 feature on a non Call line will prevent successful communication to the central All smoke detectors on the system must be tested annually by con the Installer Walk Test Prior to exiting the walk test mode sensor reset must be conducted on the system 7 2 to reset latching 4 wire smoke detectors Please refer to the smoke installation instructions on how to correctly test the detec Programming at installation may be subordinate to other UL require for the intended application Cross zones have the ability to individually protect the intended area motion detectors which overlap Cross zoning is not recommended for line security Installations nor is it to implemented on exit entry zones There is a communication delay of 30 seconds in this control panel It can removed or it can be increased up to 45 seconds at the option of the user by consulting with the Installer Do not duplicate any reporting codes This applies for all communication other than SIA sending automatic programmed reporting codes The control unit must be installed with a local sounding device and an transmission for SIA communication format of Contents 1 Introduction About the PC5010 CP 01 System 1 About the PC5010 CP 01 Manual Set 1 Main Panel Specifications 1 Additional Devices 2 2 Installation and Wiring Step

Related Files