DSC PC5015-Installation Manual-v2-4U BABT-English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc5015-installation-manual-v2-4u-babt-english-8906317542.pdf |
---|---|
Type | |
Size | 1.22 MB |
Downloads |
Text Preview
System Introduction Panel Specifications Zone Configuration 8 Fully Programmable Zones 37 Access Codes 32 User 1 System Master 2 Partition Master and 2 Duress Expandable to 32 Zones Hardwired expansion available using the PC5108 Eight Zone Expansion Module Wireless expansion available using the PC5132 NB Wireless Zone Expansion Module up to 32 wireless 418 MHz Wireless technology fully supervised Normally Closed Single EOL Double EOL 27 Zone Types 8 Programmable Zone Options 2 Partitions Alarm Output Supervised Bell Output current limited at 3 amps 12 VDC Steady or Pulsed Output Memory Will not lose programming or system status on complete AC and Battery failure Outputs Up to 14 Programmable Voltage Outputs 14 programmable options One Low Current 50 mA PGM output on main panel Eight Additional Low Current 50 mA PGM outputs available using the PC5208 module Four High Current 1 Amp PGM outputs Available Using the PC5204 module 1 PC5204 Output Fully Supervised for Siren Output 1 Amp Regulated Power Supply 500 mA Auxiliary Supply 12 VDC Positive Temperature Coefficient PTC components replace fuses Supervision for loss of AC Power Low Battery Internal Clock Locked to AC Power Frequency Requirements Transformer 16.5 VAC 40VA Battery 12 volt 4 Ah minimum rechargeable sealed lead acid Keypad Specifications 4 Different Keypads Available PC5508 8 Zone LED Keypad PC5532 32 Zone LED Keypad PC5516 16 Zone LED Keypad LCD5500 Alphanumeric Keypad Each Keypad has 5 Fully Programmable Function Keys Connect up to 8 Keypads Four Wire Quad Connection to Keybus Built in Piezoelectric Buzzer Communicator Specifications Supports all Major Formats including Scantronics 4 8 1 slot SIA and Contact ID Event Initiated Personal Paging 3 Programmable Phone Numbers 2 Account numbers DTMF and Pulse Dialling DPDT Line Seizure Anti jam Feature Split Reporting of Selected Transmissions to Each Telephone Number Trouble by Zone Telephone Line Trouble Bell Output Trouble AUX Power Supply Fault Failure to Communicate Supervision Features Power832 continuously monitors a number of possible trouble conditions including AC Power Failure Fire Trouble Low Battery Condition Loss of Internal Clock Tamper by Zone Module Fault Supervisory or Tamper Alarm Prevention Features Audible Exit Delay Urgency on Entry Delay Swinger Shutdown Communication Delay Features Keypad Activated Alarm Output and Communicator Test Keypad Lockout Audio Capability using the PC5908 Audio Interface Module which allows local intercom and Central Audible Exit Fault Quick Exit Recent Closing Transmission 2 Way Listen in All modules connect to the system via a four wire Keybus up to 1000 from main panel Event Buffer can be printed using PC5400 RS232 Serial Interface module Supports the Escort5580 Voice Prompt Module with Automation Lighting Control 256 Event Buffer Time and Date Stamped Upload Download Capability Devices maximum of eight 8 keypads can be connected to the control panel and can be any combination of the listed Different keypads with function keys can be used for different size systems 8 zone 16 and 32 zone zone LED keypad zone LED keypad zone LED keypad keypad Eight Zone Expander Module zone expander module can be used to increase the number of zones on system Up to 3 modules can be connected to increase the system zones to maximum of 32 NB Wireless Receiver Module PC5132 NB Wireless Receiver module can be used to connect up to 32 devices All devices are spread spectrum 418 MHz fully supervised use standard or alkaline batteries See Section 5.27 See PC5132 Installation Manual wireless devices are available NB NB NB Wireless Motion Detector wireless Motion Detector can be used in conjunction with the PC5132 NB Wireless Receiver to wireless space protection The unit comes with four batteries NB Wireless Slimline Universal Transmitter wireless Slimline Universal Transmitter can be used with the PC5132 NB Wireless Receiver to add door or window contacts in a smaller package The unit comes with three batteries and has contacts Power Supply Output Module PC5204 can provide up to 1 Amp of additional power for modules or devices connected to the panel The module requires a 16.5 volt AC 40 VA transformer and 4 AH battery In addition the provides 4 programmable high current voltage outputs Each output is individually with 14 different output options available See Section 5.10 Outputs Eight Low Current Output Module eight low current outputs 50 mA to the control Each output is individually programmable with 14 output options available See Section 5.10 Outputs Module Escort5580 module will turn any touch tone phone into a fully functional keypad The module also a built in interface to control up to 32 line carrier type devices for lighting and temperature See Section 5.26 Module Audio Interface Module PC5928 Audio Interface module is a simple way to incorporate paging baby listen in and door answer to the PC5015 control panel The also has built in two way voice capability for central station See 5.30 Interface Module additional devices are available Intercom Audio Station can be used in conjunction with PC5928 Audio Interface Module EXT Door Box Audio Station can be used in conjunction the PC5928 Audio Interface Module EXT R Door Box Audio Station can be used in with the PC5928 Audio Interface Module The Door PC5921 EXT PC5921 EXT R Box contains a relay so the normal door bell can be used instead the internal one generated by the PC5928 module Printer Module PC5400 Printer Module will allow the panel to print out all events that occur the system to any serial printer All events will be printed with the Partition date and the event that occurred See Section 5.27 Printer Long Range Radio Transmitter the LINKS2150 or LINKS2450 may be used to transmit alarm information over a long range radio different cabinets are available for the Power832 modules They are as follows Multi Cabinet BABT Main Control Cabinet for the PC5010 main panel Dimensions 288mm x 298mm x 78mm x 11.7 x 3 approximately Cabinet to house the PC5204 Power Supply Output Module Dimensions 213mm x 235mm x 8.4 x 9.25 x 3 approximately Cabinet to house the Escort5580 Module and PC5400 Printer Module Dimensions 229mm x x 65mm 9 x 7 x 2.6 approximately Cabinet to house the PC5108 Zone Expander Module and the PC5208 Eight Low Current Module Dimensions 153mm x 122mm x 38mm 6 x 4.8 x 1.5 approximately Plastic Cabinet to house the PC5108 Zone Expander Module and the PC5208 Eight Low Output Module Dimensions 146mm x 105mm x 25.5mm 5.75 x 4.2 x 1 approximately are two different backplates available for keypads to locate an Audio Station next to the keypad Backplate backplate is to be used when an Audio Station is to be located next to keypad Dimensions 208mm x 115mm x 18mm 8.2 x 4.5 x 0.25 Backplate backplate is to be used when an Audio Station is to be located next to a In addition the backplate will allow you to mount a PC5108 Zone