DSC PC5015-Programming Worksheet-v2-4U BABT-English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc5015-programming-worksheet-v2-4u-babt-english-3596024187.pdf |
---|---|
Type | |
Size | 731.76 KB |
Downloads |
Text Preview
Zone Assignment Zone 1 16 Assignment Del Zone 17 32 Assignment Del Programming Keypad Assignment Section 2.6 Assignment This must be done at each keypad requiring programming Partition and Slot Valid entries are 0 Global 1 and 2 for the Partition and 1 8 for the Slot Function Key 1 Assignment Valid entries are 00 18 Function Key 2 Assignment Valid entries are 00 18 Function Key 3 Assignment Valid entries are 00 18 Function Key 4 Assignment Valid entries are 00 18 Function Key 5 Assignment Valid entries are 00 18 Null Key Not Used Select Partition 1 Select Partition 2 Stay Arm Away Arm Q 9 No Entry Arm Q 4 Chime On Off Q 6 System Test Q 1 Bypass Mode Q 2 Trouble Display Q 3 Alarm Memory Q 5 User Programming Q 6 User Functions Q 7 1 Utility Output Q 7 2 Sensor Reset General Voice Prompt Help Q 0 Quick Exit Q 1 Reactivate Stay Away Identified Voice Prompt Help Defaults Defaults 1 2 3 4 5 6 7 8 and Address 1 2 3 4 5 System Programming Definitions Null Zone Not Used Delay 1 Delay 2 Instant Interior Interior Stay Away Delay Stay Away Delayed 24 Hour Fire Standar 24 hour Fire 24 Hour Supervisory Buzzer 24 Hour Burglary 24 Hour Holdup 24 Hour Gas 24 Hour Heat 24 Hour Medical 24 Hour Panic 24 Hour Emergency 24 Hour Sprinkler 24 Hour Water Zone 1 8 Definitions Section 5.1 Definitions 24 Hour Freeze 24 Hour Latching Tamper Momentary Keyswitch Arm Maintained Keyswitch Arm Interior Delay 24 Hour Bell Buzzer Push to Set Delay 24 Hr Fire Wireless Standard 24 Hr Fire Wireless Zone 9 16 Definitions Section 5.1 Definitions Zone 17 24 Definitions Section 5.1 Definitions Zone 25 32 Definitions Section 5.1 Definitions Zone 1 Zone 2 Zone 3 Zone 4 Zone 9 Zone 10 Zone 11 Zone 12 Zone 17 Zone 18 Zone 19 Zone 20 Zone 25 Zone 26 Zone 27 Zone 28 System Times Delay 1 Delay 2 Delay Cut off Zone 5 Zone 6 Zone 7 Zone 8 Zone 13 Zone 14 Zone 15 Zone 16 Zone 21 Zone 22 Zone 23 Zone 24 Zone 29 Zone 30 Zone 31 Zone 32 Installer Code Section 4.1 to Enter Installer Programming Master Code Section 3.1 Codes Maintenance Code Section 3.1 Codes Output Options For future use Burglary and Fire Bell Output Utility Output Sensor Reset System Partition Armed Status Ready To Arm Keypad Buzzer Follow Mode Courtesy Pulse System Trouble Output with Trouble options Latched System Event Strobe with Event options System Tamper all sources zones kpd modules TLM and Alarm Kissoff Output Ground Start Pulse For Future Use PC5015 PGM Output Programming PGM 1 2 Section 5.10 Outputs PC5208 PGM Output Programming PGM 3 10 Section 5.10 Outputs PGM 7 PGM 8 PGM 9 PGM 10 PC5204 PGM Output Programming PGM 11 14 Section 5.10 Outputs PGM 1 PGM 2 PGM 3 PGM 4 PGM 5 PGM 6 PGM 11 PGM 12 PGM 13 PGM 14 Keypad Lockout Options Section 5.21 Lockout of Invalid Codes Before Lockout Duration in minutes First System Option Code Second System Option Code Closed Loops End of Line Resistors Zones 1 4 enabled Zones 5 8 enabled 8 is Fast Loop Response Future Use Buffer Follows Swinger Shutdown Exit Fault enabled