DSC PC5020 v3 1 - Installation Manual - English - PowerSeries 8-64 Zone Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc5020-v3-1-installation-manual-english-powerseries-8-64-zone-control-panel-7685432109.pdf |
---|---|
Type | |
Size | 2.06 MB |
Downloads |
Text Preview
This manual contains information on limitations regarding product use and function and information on the as to liability of the manufacturer The entire manual should be carefully read C U R M Version 3.1 v1.3 and higher Features Support Support FAR Activity Arming Partition Arm Pre Alert Test Zoning Automatic ID Buzzer PC5020 v3.1 supports the new PC5200 Power Supply module See PC5200 Power Supply Output Module Pg 2 PC5020 v3.1 supports the PC5936 15 station audio matrix module See PC5936 Audio Interface Module Pg 2 False Alarm Reduction has been incorporated in this version See SIA Reporting Codes App A feature enables the system or partition to arm if there is no zone activity for a programmed time period See 191 198 No Activity Timer Partition 1 8 Pg 27 Auto Arm Pre alert Time is now programmable The default value for this timer has been extended to 5 minutes Section 199 Auto Arming Pre Alert Time Pg 27 this feature enabled the panel will not send a test transmission if there has been any transmission received by receiver within the programmed time See Section 018 Sixth System Option Codes Pg 24 feature requires two or more trips on a zone s specified as zones within a specified time before starting alarm sequence The Cross Zone option is programmable by zone via Attribute 9 See Section 018 Sixth Sys Option Codes Pg 24 selecting Automatic Contact ID for reporting the reporting code will represent how a zone is defined according the SIA specification for Contact ID If Automatic Contact ID is enabled see Appendix A for reporting codes that be used for each zone type enabled and the system or Partition is in alarm all assigned keypad buzzers will follow the bell output When the keypad buzzers will only sound for buzzer type alarms This option is off at default See Section 018 System Option Codes Option 5 Pg 25 Zone Types Sections 001 004 Zone Definitions Pg 21 Type 27 Delayed 24 Hour Waterflow Zone Type 28 Instant 24 Hour Waterflow Zone Type 29 Auto Verified Fire Zone Type 30 Fire Supervisory Zone Type 31 Day Zone Silence Option Door Chime Verbal Alarm option affects the Instant Waterflow Zone and the Delay Water flow Zone option does NOT allow the user to silence alarms manually automatically or by a system reset until all waterflow are returned to their restored state See Section 018 Sixth System Option Codes Option 4 Pg 25 feature is available when the ESCORT5580 v3.00 and the PC5936 v1.00 are used This feature enables the Chime to verbally annunciate the Zone that has been violated instead of a series of beeps See Section 018 System Option Codes Option 2 3 Pg 33 See associated Installation Manuals Loop PC5020 v3.1 can configure any or all onboard zones for 36 ms Loop Response See Section 030 Fast Loop Pg 26 Not verified by UL 011 Option 6 Option 6 Option 7 164 6th Entry 7th Entry 8th Entry 1st Entry 4th Entry 11th Entry Option 2 Option 3 Option 4 Installer Programming Quick Reference Chart False Alarm Reduction requirement system for SIA FAR Installations 1 PC5020 Control panel 2 Local annunciation devices local annunciation devices may be any combination of the following keypads LCD5500Z PKP LCD LCD5501Z PKP ICN following optional subassembly modules also bear the SIA FAR classification may be used if desired Receiver Module initiating devices WLS 912 433 WLS904PL 433 WLS914 433 and Number Section Zone Expander Module Initiating devices Bravo 200series 300series 400series 500series series AC 100 Encore 300series Force 200series 210series MN240 2 wire Addressable Loop Interface Module Initiating devices AMB 300 500 600 AMA 100 AMP 700 Low Current PGM Output Module Auxiliary Power Supply with PGM output ports Printer Module Times Access to Entry Delays and Exit Delay for each partition and Bell Time Out for the system Outputs Access to PGM Output programming for the main board PC5208 and PC5204 modules Output in Section in Sections 501 514 Partition Assignments in Section 551 564 Exit Beeps Enables beeps from the keypad for the duration of Exit Delay Zoning Enables Cross Zoning for the entire system Individual zones can be enabled for Cross zoning via Zone in Sections 101 164 Delay Restart Enables the Exit Delay Restart feature Attributes Access to zone attributes such as Audible Bell Swinger Shutdown Transmission Delay and Cross Zone Timer Access to the programmable Cross Zone timer Waiting Cancel Dialing String Access to the Dialing sequence used to disable Call Waiting Zone Reporting Code Access to the reporting code for Cross Zone Alarm not Verified Reporting Code Access to the reporting code for Burglary Not Verified Cancelled Reporting Code Access to the reporting code for Alarm Cancelled 1st and 2nd Entries Test End and Begin Reporting Codes Access to the reporting codes for Walk Test Begin and Walk Test End Shutdown for Alarms Access to the Swinger Shutdown limit for zone alarms Delay Access to the programmable delay before communicating alarms Cancel Window Access to the programmable Communications Cancel window Comms During Walk Test Enables Communication of zone alarms while installer Walk Test is active Cancelled Message Enables the Cancelled message display on all keypads Waiting Cancel Enables the use of the Call Waiting Cancel string in programmed in Section 304 Walk Test Mode Enable Disable Installer Walk Test mode This mode can be used to test each zone on the sys for proper functionality Wireless smoke detectors WLS906 433 cannot be employed in conjunc with the PC5132 433 Wireless receiver for SIA FAR Installations Addressable smoke detectors AMS220 AMS220T cannot be employed conjunction with the PC5100 Addressable loop module for SIA FAR Fire Alarm Verification feature Auto Verified Fire zone is not supported Two wire smoke detectors zones This feature may be enabled for 4 smoke detectors only Call Waiting Cancel Section 382 Option 4 feature on a non Call Wait line will prevent successful communication to the central station Programming at Installation may be subordinate to other UL require for the intended application Unvacated premises When the system partition is armed in Stay Mode the exit delay time expires the system will automatically Away Arm will function properly provided that the premises are not exited via a 1 or Delay 2 There must be a minimum of one Stay Away or Delay zone enrolled on the partition Cross zones have the ability to individually protect the intended area ex detectors which overlap Cross zoning is not recommended for Line security Installations nor is it to implemented on exit entry zones There is a Communication Delay of 30 seconds in this control panel It be removed or it can be increased up to 45 seconds at the option of end user by consulting with the Installer Do not duplicate any reporting codes This applies for all communication other than SIA sending automatic programmed reporting codes of Contents 1 Introduction About the Power864 System 1 About the Power864 Manual Set 1 Main Panel Specifications 1 Additional Devices 2 2 Installation and Wiring Steps 4 Descriptions 4 Wire Routing for Power Non Power Limited 5 Operation and Wiring 5 Current Ratings Modules Accessories 5 Assigning Zones to Zone Expanders 6 Assignment