DSC PC5108 - v2 0 - Installation Instructions - En - Fr - R005

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc5108-v2-0-installation-instructions-en-fr-r005-4738951602.pdf
Type PDF
Size 1.05 MB
Downloads

Text Preview

PC5108 v2.0 Installation Instructions Expander Module Installation sheet shall be used in conjunction with the Installation Manual of the equipment to which PC5108 is connected or powered from e g alarm controller supply etc The PC5108 module can be used to extend up to 8 hardwired input on the compatible DSC Alarm Controllers models PC5015 PC1864 PC1832 and product meets the requirements of Class II Grade 2 equipment as per EN50131 and prEN50131 1 2004 Standards may be installed in the same metallic cabinet as the alarm controller power model Power UC1 PC5003C or in a separate enclosure PC4003C Internal external wiring for the PC5108 shall be routed supported clamped or secured in manner that reduces the likelihood of a excessive strain on wire and terminal connec b loosening of terminal connections and c damage of conductor insulation range 10 to 55 Humidity 93 non condensing rating 12VDC 135mA provided by the alarm controller or separate power supply current draw 35mA set and unset state dimensions 45mm x 92mm output ratings 12VDC 15 10 when Input voltage is between 85 of rated value and output current is between 0mA 100mA max fuse PTC used on circuit board instead of replaceable fuses Descriptions 12VDC 100mA Limited Used to tamper the cabinet in which the PC5108 is mounted Connect a nor closed NC switch across TAM and BLK If the tamper is not being used connect a of wire across TAM and BLK to remove the trouble condition is a built in tamper switch on the expander module located in the top left corner the circuit board If the cabinet in which the PC5108 is mounted has the hardware to depress this tamper switch do not connect anything to the TAM terminal Used to provide power for devices Maximum current draw is not to exceed 100 Connect the positive lead of powered devices to VAUX and the negative to BLK or COM terminal The 4 wire Keybus connection is used by the panel to communicate with the Connect the RED BLK YEL and GRN terminals to the KEYBUS terminals on the PC1832 PC1864 PC5015 main control to Z8 Wire the zones according to the description found in the control panel Manual P N 29008247 PC5108 can be installed in the metal enclosures listed below Tamper protection can be installed on all enclosures including door opening protection and or from the mounting position Doors can be secured using screws or keylock Model PC5003C removable door made of 22Ga steel painted 248mm L x 298mm W x 76mm H Weight 1500g Model PC5003C hinged door made of 1.2mm thick steel painted 248mm L x 298mm W x 76mm H Weight 2500g Model Power UC1 made of 18Ga steel painted 315mm L x 319mm W x 100mm H Weight 3150g Model PC4003C made of 18Ga steel painted 230mm L x 180mm W x 75mm D Weight 1050g Settings PC5108 module can be used to add up to 8 additional hardwired zones to the PC1832 PC1864 or PC5015 control panel see Installation Manual for com installation instructions control panels with software 3 x and higher the v2.0 will operate in a group of eight zones to the following jumper Zones A Zones1 8 B not used Assigned Zones Disabled ON Zones 9 16 OFF ON Zones 17 24 OFF ON Zones 25 32 OFF Zones 33 40 ON OFF Zones 41 48 OFF OFF Zones 49 56 57 64 OFF OFF control panels with software 2 x and lower the v2.0 will operate in groups of four zones Refer the following jumper set Zones A Zones1 4 B Zones 5 8 ON OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF Assigned Disabled Disabled 9 12 13 16 17 20 21 24 25 28 29 32 Add Hardwired Zones to a Control Panel Connect module to the Keybus with the panel powered down Set the jumpers on the module Power up the system Enter section 902 and wait 1 minute Enter section 903 to verify that the module is supervised Define the zones in sections 002 004 109 164 for PC1616 PC1832 PC5010 or PC5020 Add the zones to the appropriate partition in sections 202 265 WARRANTY Security Controls warrants that for a period of twelve months from the date of pur the product shall be free of defects in materials and workmanship under normal use that in fulfilment of any breach of such warranty Digital Security Controls shall at its repair or replace the defective equipment upon return of the equipment to its factory warranty applies only to defects in parts and workmanship and not to damage incurred shipping or handling or damage due to causes beyond the control of Digital Security such as lightning excessive voltage mechanical shock water damage or damage out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of and all other warranties whether expressed or implied and of all other obligations or on the part of Digital Security Controls This warranty contains the entire war Digital Security Controls neither assumes responsibility for nor authorizes any other purporting to act on its behalf to modify or to change this warranty nor to assume it any other warranty or liability concerning this product In no event shall Digital Secu Controls be liable for any direct or indirect or consequential damages loss of antici profits loss of time or any other losses incurred by the buyer in connection with the installation or operation or failure of this product Digital Security Controls recommends that the entire system be completely on a regular basis However despite frequent testing and due to but not limited criminal tampering or electrical disruption it is possible for this product to fail to as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer instructions may cause interfer to radio and television reception It has been type tested and found to comply with limits for Class B device in accordance with the specifications in Subpart of Part of FCC Rules which are designed to provide reasonable protection against such inter in any residential installation However there is no guarantee that interference not occur in a particular installation If this equipment does cause interference to or radio reception which can be determined by turning the equipment off and the user is encouraged to try to correct the interference by one or more of the follow measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are different circuits necessary the user should consult the dealer or an experienced radio television techni for additional suggestions The user may find the following booklet prepared by the useful to Identify and Resolve Radio Television Interference Problems booklet is available from the U S Government Printing Office Washington D C Stock 004 000 00345 4 CANADA STATEMENT Tyco Security Products All Rights Reserved Canada www dsc com Support 1 800 387 3630 Canada U S 905 760 3036 v2.0 Instructions d installation d extension de 8 zones feuille d doit utilis avec le manuel d du mat le PC5108 est connect et ou aliment par exemple contr d d etc Le PC5108 peut utilis pour ajouter au Central un maximum de 8 zones c aux panneaux contr produit est conforme aux exigences relatives aux appareils de classe II niveau 2 la norme EN50131 1 1997 et la norme prEN50131 1 2004 PC5108 peut install dans la m enceinte m que le contr alimentation ou dans une enceinte s Le c interne et ou pour ce module devra achemin support attach de fa r la

Related Files