DSC PC5108 WEB en sp

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc5108-web-en-sp-9172860534.pdf
Type PDF
Size 750.78 KB
Downloads

Text Preview

v2.0 Installation Instructions Zone Expander Module Installation sheet shall be used in conjunction with the Installation Manual of the equipment to which PC5108FLR is connected or powered from e g alarm controller supply etc The PC5108FLR module can be used to extend up to 8 hardwired fast response zones on the compatible DSC Alarm Controllers models PC5020 PC1864 and PC1616 The fast loop response will be approximately 25ms may be installed in the same metallic cabinet as the alarm controller power model Power UC1 PC5003C or in a separate enclosure PC4003C Internal and external wiring for the PC5108FLR shall be routed supported clamped or secured in a that reduces the likelihood of a excessive strain on wire and terminal connections loosening of terminal connections and c damage of conductor insulation range 10 to 55 Humidity 93 non condensing rating 12VDC 135mA provided by the alarm controller or separate power supply current draw 35mA set and unset state dimensions 45mm x 92mm output ratings 12VDC 15 10 when Input voltage is between 85 of rated value and output current is between 0mA 100mA max fuse PTC used on circuit board instead of replaceable fuses Descriptions BLK YEL GRN COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8Z8 COM LIMITED 100mA DEVICES POWER TO OR TO Used to tamper the cabinet in which the PC5108FLR is mounted Connect a nor closed NC switch across TAM and BLK If the tamper is not being used connect a of wire across TAM and BLK to remove the trouble condition is a built in tamper switch on the expander module located in the top left corner of circuit board If the cabinet in which the PC5108FLR is mounted has the hardware to depress this tamper switch do not connect anything to the TAM terminal Used to provide power for devices Maximum current draw is not to exceed 100 Connect the positive lead of powered devices to VAUX and the negative to BLK or any terminal The 4 wire KEYBUS connection is used by the panel to communicate with the Connect the RED BLK YEL and GRN terminals to the KEYBUS terminals on the PC1832 PC1864 PC5020 main control to Z8 Wire the zones according to the description found in the control panel Instal Manual PC5108FLR can be installed in the metal enclosures listed below Tamper protection can be installed on all enclosures including door opening protection and or from the mounting position Doors can be secured using screws or keylock PC5003C removable door made of 22Ga steel painted dimensions x 298mm W x 76mm H weight 1500g PC5003C hinged door made of 1.2mm thick steel painted dimensions x 298mm W x 76mm H weight 2500g Power UC1 made of 18Ga steel painted dimensions 315mm L x 319mm W x PC4003C made of 18Ga steel painted dimensions 230mm L x 180mm W x weight 3150g weight 1050g Settings PC5108FLR module can be used add up to 8 additional hardwired loop response zones to the control panel see Installa Manual for complete installation PC5108FLR will operate in a sin group of eight zones Refer to the jumper settings Zones A Zones1 8 B not used Assigned Zones Disabled ON Zones 9 16 OFF ON Zones 17 24 OFF ON Zones 25 32 OFF Zones 33 40 ON OFF Zones 41 48 OFF OFF Zones 49 56 OFF OFF 57 64 Add Hardwired Zones to a Control Panel Connect module to the Keybus with the panel powered down Set the jumpers on the module Power up the system Enter section 902 and wait 1 minute Enter section 903 to verify that the module is supervised Define the zones in sections 002 004 for PC1616 PC1832 PC1864 or PC5020 Add the zones to the appropriate partition in sections 202 265 WARRANTY Security Controls warrants that for a period of twelve months from the date of pur the product shall be free of defects in materials and workmanship under normal use and in fulfilment of any breach of such warranty Digital Security Controls shall at its option or replace the defective equipment upon return of the equipment to its factory This applies only to defects in parts and workmanship and not to damage incurred in or handling or damage due to causes beyond the control of Digital Security Controls as lightning excessive voltage mechanical shock water damage or damage arising out abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any all other warranties whether expressed or implied and of all other obligations or liabilities the part of Digital Security Controls This warranty contains the entire warranty Digital Controls neither assumes responsibility for nor authorizes any other person purport to act on its behalf to modify or to change this warranty nor to assume for it any other or liability concerning this product In no event shall Digital Security Controls be for any direct or indirect or consequential damages loss of anticipated profits loss of or any other losses incurred by the buyer in connection with the purchase installation or or failure of this product Digital Security Controls recommends that the entire system be completely on a regular basis However despite frequent testing and due to but not limited to tampering or electrical disruption it is possible for this product to fail to per as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer instructions may cause interference radio and television reception It has been type tested and found to comply with the limits Class B device in accordance with the specifications in Subpart of Part 15 of FCC which are designed to provide reasonable protection against such interference in any installation However there is no guarantee that interference will not occur in a installation If this equipment does cause interference to television or radio recep which can be determined by turning the equipment off and on the user is encouraged try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on circuits necessary the user should consult the dealer or an experienced radio television technician additional suggestions The user may find the following booklet prepared by the FCC to Identify and Resolve Radio Television Interference Problems This book is available from the U S Government Printing Office Washington D C 20402 Stock Digital Security Controls Toronto Canada www dsc com Support 1 800 387 3630 Canada U S 905 760 3036 in Canada de instalaci del PC5108FLR expansor de 8 zonas folleto de instalaci debe utilizarse junto con el Manual de Instalaci del equipo de DSC cual se conectar el PC5108FLR o desde donde recibir alimentac Ej controlador de fuente de alimentaci etc Se puede utilizar el m PC5108FLR para ampliar el con hasta ocho zonas de respuesta r de circuito con hilo en controladores de DSC compatibles que son los modelos PC5020 PC1864 PC1832 y PC1616 La r del circuito ser de aproximadamente 25 ms PC5108FLR puede instalarse en la misma caja met del controlador de alarma fuente de modelo Power UC1 PC5003C o en un compartimiento separado PC4003C El interno y o externo del PC5108FLR debe orientarse soportarse fijarse o protegerse de en reducir la probabilidad de a tensi excesiva bajo lo hilos y conexiones de los b aflojado de las conexiones de los terminales y c da al aislamiento de los de temperatura 10

Related Files