DSC PC5204 en fr 29001761R008 WEB
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pc5204-en-fr-29001761r008-web-6491735082.pdf |
---|---|
Type | |
Size | 1015.29 KB |
Downloads |
Text Preview
v2.0 Installation Instructions Supply Four High Current Outputs Module PC5204 can be used to provide up to 1.0A of additional current and be used to add up to four high current programmable outputs to the DSC Alarm Controllers models PC5010 PC5015 PC5020 PC1832 and PC1616 Installation sheet shall be used in conjunction with the Installation of the DSC equipment to which PC5204 is connected or powered e g alarm controller power supply etc product meets the requirements of Class II Grade 2 equipment as per and prEN50131 1 2004 Standards Supply Type A as per EN50131 6 Standard range 10C to 50C Humidity 93 non condensing ratings 220V 240Vac 50 60Hz 200mA required mounted in the same enclosure and permanently connected secondary ratings 16.5Vac 40VA min current draw 20mA set and unset state dimensions 145 mm x 83 mm output ratings 12VDC 15 10 when Input voltage is between 85 to110 of value and output current is between 0.0A 1.0A max fuse PTC used on circuit board instead of replaceable fuses ripple voltage 600mVp p max Overvoltage protection devices required on the outputs device rechargeable battery rated 12VDC Replace battery every 3 5 years capacity 4Ah 7Ah or 14Ah 2 x 7Ah max standby time 24h when using 14Ah battery capacity and AUX current limited to max Refer to table below time less than 72 hours battery trouble indication threshold 11.5VDC deep discharge protection cut off at 9.5VDC for loss of primary power source AC Fail battery fail or battery low voltage Bat Trouble with indication provided on the keypad 1 Current Draw AUX CURRENT DRAW Require Requirements 40VA min Listed Enclosures Time min hours be used with the PC5020CF only min 2x7Ah 40VA hours Fire Burglary 40VA min hours 37VA min 2x7Ah PC4050CRAR fire bur hours 9 0 0 1 7 6 1 R0 0 8 Descriptions US Market Only 230 VAC Supervised the PC5204 requires a 16.5V 37VA or 16V 40VA trans Connect the primary of the transformer to an unswitched AC maximum current draw is 0.5A and connect the secondary of the US market only to these terminals This terminal is used to provide power for devices modules refer to Table 1 for maximum ratings the positive lead of powered devices to AUX and the negative to proper output terminal O1 to O4 This can be used to tamper the cabinet in which the PC5204 is Connect a normally closed NC switch across TAM and BLK If tamper is not being used connect a piece of wire across TAM and BLK remove the trouble condition The 4 wire Keybus connection is used by the panel to communi with the module Connect the RED BLK YEL GRN terminals to the BLK YEL GRN Keybus terminals on the PC50X0 control panel to O4 Wire the positive lead of the device output the AUX terminal and the negative lead to required output terminal O1 to O4 NOTE Output O1 is supervised the same manner as the Bell Output of the If O1 is not used if no continuous load connected or if a siren is connected a 1000W DSC model EOLR 1 must be connected order to prevent the indication of a trouble This diagram is an example of how to various devices to the outputs The PC5204 is not suitable for fire alarm annunciation PC5204 can be installed in the metal enclosures listed below protection switches can be installed on all enclosures includ door opening protection and or removal from the mounting posi Doors can be secured using screws or keylock PC5204 may be within the same metallic cabinet as the alarm controller power model Power UC1 PC5003C or in a separate enclosure model Internal and or external wiring for this module shall be routed clamped or secured in a manner that reduces the likelihood of excessive strain on wire and on terminal connections loosening of terminal connections and of conductor insulation Siren maximum polarity RED Model PC5003C removable door made of 22Ga steel painted 248mm L x 298mm W x 76mm H weight 1500g Model PC5003C hinged door made of 1.2mm thick steel painted 248mm L x 298mm W x 76mm H weight 2500g Model Power UC1 made of 18Ga steel painted dimensions x 319mm W x 100mm H weight 3150g Model PC4003C made of 18Ga steel painted dimensions x 180mm W x 75mm D weight 1050g WARRANTY Security Controls warrants that for a period of twelve months from the of purchase the product shall be free of defects in materials and workman under normal use and that in fulfilment of any breach of such warranty Dig Security Controls shall at its option repair or replace the defective upon return of the equipment to its factory This warranty applies to defects in parts and workmanship and not to damage incurred in shipping handling or damage due to causes beyond the control of Digital Security Con such as lightning excessive voltage mechanical shock water damage or arising out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all obligations or liabilities on the part of Digital Security Controls This war contains the entire warranty Digital Security Controls neither assumes for nor authorizes any other person purporting to act on its behalf modify or to change this warranty nor to assume for it any other warranty or concerning this product In no event shall Digital Security Controls be for any direct or indirect or consequential damages loss of anticipated loss of time or any other losses incurred by the buyer in connection with purchase installation or operation or failure of this product Digital Security Controls recommends that the entire system be com tested on a regular basis However despite frequent testing and due to not limited to criminal tampering or electrical disruption it is possible for product to fail to perform as expected COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Con could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed used properly in strict accordance with the manufacturer cid 146 s instructions cause interference to radio and television reception It has been type tested found to comply with the limits for Class B device in accordance with the in Subpart cid 147 B cid 148 of Part 15 of FCC Rules which are designed to reasonable protection against such interference in any residential instal However there is no guarantee that interference will not occur in a par installation If this equipment does cause interference to television or reception which can be determined by turning the equipment off and on user is encouraged to try to correct the interference by one or more of the measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and are on different circuits necessary the user should consult the dealer or an experienced radio televi technician for additional suggestions The user may find the following prepared by the FCC useful cid 147 How to Identify and Resolve Radio Tele Interference Problems cid 148 This booklet is available from the U S Govern Printing Office Washington D C 20402 Stock 004 000 00345 4 Digital Security Controls Toronto Canada cid 129 www dsc com Support 1 800 387 3630 Canada U S 905 760 3036 in Canada v2.0 Instructions d installation d alimentation quatre sorties courant PC5204 peut utilis pour fournir un maximum de 1A de cou suppl et il peut utilis pour ajouter quatre sorties de courant au panneau de contr PC5010 PC5020 PC1616