TABLE OF CONTENTS 3 3 the Panel 4 the Keypad 4 5 Zone Wiring 5 Power Connection 5 Terminal Connections 5 Terminal Connection 5 Terminal Connection 6 Power Wiring 6 Connection 6 Line Wiring 6 FUNCTIONS 7 Code 7 Programming Code 7 7 Arming 7 Arming 7 8 Note about Keypad Commands 8 8 Code Zone Bypassing 8 Trouble Conditions 8 Alarm Memory 9 Test 9 Code Program Access Codes 9 Chime On Off 9 Output Command 9 Code Installer Programming Command 10 Code At Home Arming 10 Zones 10 the Keypad Sounder Tone and Backlighting 10 GUIDE 05 through 07 Enabling System Functions 11 Data Programming 11 Programming to the Factory Default Settings 12 SECTIONS Zone Definitions 13 System Times 14 Code 14 Programmable Output Options PGM Terminal 14 First System Option Code 15 Second System Option Code 15 Third System Option Code 16 First Phone Number 16 Second Phone Number 16 Customer Account Code 16 Communications 16 Zone Alarm and Restoral Reporting Codes 16 Opening and Closing Reporting Codes 16 Maintenance and Priority Codes 17 Downloading Access Code 17 Do Not Use 17 THE RECORD WORKSHEETS DIAGRAM WARRANTY Fully featured security system with Trouble Alarm Memory Master Code and 3 Access Codes Quick Arming and Arming Door Chime 3 one touch Keypad and more Digital Communicator with programmable Formats 20 bps 3 1 4 1 4 2 4 End of Line Resistor Supervised Zones 6 Programmable Zone Types with Silent or Audible Programmable Output with 4 options Dedicated Strobe latched alarm Output Momentary or Maintained Keyswitch Arming All Installer Programming can be done at the or through downloading EEPROM memory retains all programming even all power is removed from the control panel Advanced static and lightning protection unique circuit board design stops damaging at the wiring terminals and transient devices are placed in all critical areas for protection Control Panel Four fully programmable zones Zones are End of Line Resistor supervised All zones programmable as 24 Hour Pulsed Alarm Maximum zone loop resistance 100 ohms Bell Siren Output fused for 5A Bell Siren Alarms steady and pulsed alarms Programmable Output 50 mA with 4 options Auxiliary Power Output 800 mA with 40 VA transformer 500 mA with 20 VA transformer Maximum 3 Keypads per system and Keyswitch Required Battery 12 VDC 1.2 Ah provides 4 hours of stand by at mA Auxiliary Output 4.0 Ah provides 4 hours of stand by at mA Auxiliary Output Required Transformer 16 VAC 20 40 VA Panel dimensions 7 high 9 wide