DSC PC585 v2 5U UK IM EN INT

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc585-v2-5u-uk-im-en-int-5938076214.pdf
Type PDF
Size 1.52 MB
Downloads

Text Preview

This manual contains information on limitations regarding product use and function and information on the as to liability of the manufacturer The entire manual should be carefully read Version 2.5U DLS 3 v1.3 and higher Back Cover for New Features in Version 2.5U CTR21 Notes This equipment has been approved in accordance with Council Decision 98 482 EC pan European single terminal connection to the public switched telephone network However due to differences between the individual PSTNs provided in differ countries the approval does not of itself give an unconditional assurance of suc operation on every PSTN network termination point the event of problems you should contact your equipment supplier in the first This equipment was designed to work on the PSTN networks in the following countries Belgium Denmark France Germany Greece Iceland Ireland Italy Israel Portugal Spain Sweden Switzerland Netherlands and the UK there is special Software programming to be done for a specific country this will be in the Programming Worksheets booklet Therefore please consult the Work booklet during programming of the equipment and take note of any special specific requirements for the PSTN this equipment is to be connected to a PSTN in a country that is not listed above contact the vendor to check for compatibility with the network in question This equipment has only been approved for and is only intended for use with DTMF Please see page 17 and page 39 for information on programming section In order to comply with CTR21 regulations the Maximum Number of Dialing Attempts a control panel can make must not exceed 15 Please see page 35 for informa on programming section 160 of Contents 1 System Introduction Specifications 1 Additional Devices 2 Out of the Box 2 2 Getting Started Installation Steps 3 Terminal Descriptions 3 Keybus Operation and Wiring 4 Current Ratings Modules and 4 Keypad Assignment 4 Supervision 5 Removing Modules 5 Zone Wiring 5 Fire Zone Wiring 6 GSM1000 Zone Wiring 6 Keypad Zones 6 3 Keypad Commands Arming and Disarming 8 Auto Bypass Stay Arming 8 Automatic Arming 8 Resetting the System After an Alarm 8 Commands 8 Function Keys 11 Features Available for the LCD5500Z 12 4 How to Program Installer Programming 13 Programming Decimal Data 13 Programming HEX Data 13 Programming Toggle Option Sections 14 Viewing Programming 14 5 Program Descriptions Programming Security Codes 15 Zone Programming 15 Zone Attributes 16 Assigning Keypad Zones 17 Communicator Dialing 17 Communicator Account Numbers 17 Communicator Telephone Numbers 17 Communicator Reporting Codes 18 Communicator Reporting Formats 19 Downloading 20 PGM Output Options 21 Telephone Line Monitor TLM 22 Bell 23 Test Transmission 23 Transmission Delay 23 Fire Auxiliary and Panic Keys 23 Arming Disarming Options 23 Entry Exit Delay Options 24 Swinger Shutdown 24 Event Buffer 24 Remote Reset of System Lock and Reset Codes 24 Keypad Lockout Options 25 Keypad Blanking 25 Keypad Backlighting 25 Keypad Tampers 25 GSM1000 Cellular Communicators 25 Additional System Modules 26 Engineer s Reset 26 Clock Adjust 26 Timebase 26 Resetting Factory Defaults 26 Installer Lockout 27 Walk Test Installer 27 6 Programming Worksheets A Reporting Codes B Programming LCD Keypads Wiring Diagram 1 System Introduction Specifications Software Support Zone Configuration v2.5U uses DLS 3 v1.2 and up fully programmable zones system expandable to zones using keypad zone inputs and wireless access codes one master code one maintenance two duress codes two supervision codes and 32 access codes zone types 8 programmable zone attributes closed single EOL and double EOL zone wiring wireless zones available using the PC5132 Wireless Alarm Output Supervised Bell Output current limited at 3 12VDC or Pulsed Output Memory not lose programming or system status on com AC and Battery failure Outputs programmable voltage outputs 18 programmable 300mA PGM2 50mA 1.5 Amp Regulated Power Supply mA Auxiliary Supply 12 VDC Temperature Coefficient PTC components fuses for loss of AC power low battery Requirements 16.5 VAC 40VA 12 volt 4 Ah minimum rechargeable sealed acid battery Keypad Specifications keypads available PC1555RKZ eight zone LED keypad with zone input PC5508Z eight zone LED keypad with zone input LCD5500Z Alphanumeric keypad with zone input LCD5501Z Fixed Message Keypad All keypads have five programmable function keys up to eight keypads Quad connection to Keybus in piezoelectric buzzer Communicator Specifications major communication formats including SIA Contact ID personal paging programmable telephone numbers account numbers GSM1000 cellular communication LINKS2X50 Long Range Radio Transmitter dialing line seizure feature reporting of selected transmissions to each tele number

Related Files