DSC PC5950 PC1616 1832 1864 V4 2

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc5950-pc1616-1832-1864-v4-2-9701632458.pdf
Type PDF
Size 598.82 KB
Downloads

Text Preview

Notes PC5950 2 Way Audio Verification SERIES PC1616 1832 1864 V4.2 Module PC5950 provides talk listen in capability for audio verification alarms The module permits the station to monitor microphones and communicate to the occupants through speakers in with SIA false alarm reduction legislation The user can also remotely initiate audio monitoring of premises using a touchtone phone addressable zones has eight step process Connect the PC5950 to the KEYBUS Connect the speakers to the PC5950 the central station phone number the account number the communicator format two way audio verification the audio Control Options the Miscellaneous audio control Optional the Microphone input assignment the Audio Options Optional Sections 301 310 350 381 Opt 5 On 802 30 37 802 38 802 40 47 802 10 Number 1 Number Format Option 1Two Way Audio Enable Audio Control Options Audio Control Options Optional input assignment Options Optional 1 Connect the PC5950 to the KEYBUS the four KEYBUS terminals of the PC5100 to the four KEYBUS terminals of the panel the PC5950 module is not connected to the KEYBUS Section 802 cannot be 2 Connect the speakers to the PC5950 to 4 audio stations 4 microphones and 2 speakers can be connected to the PC5950 audio interface Each Audio Station mush be home run to the interface module via shielded 22 gauge 4 conductor Each Audio Station can be up to 500ft 152m from the PC5950 Do not wire the Keybus with shielded 1 Program the Telephone Number the central station phone number in Section 301 Page 49 2 Program the Account Number the account number in Section 310 If contact ID or Pulse format is required also program 311 thru 318 for Partition 1 thru 8 a pulse format or a Contact ID format is being used program a HEX digit A for any digit in the account number 3 Program the Communication Format the communicator format in Section 350 4 Enable two way verification enable two way audio verification for telephone number 1 enable Option 5 in Section 381 5 Program the Audio Control Options for zones 1 thru 64 default all zones are disabled and will not initiate a two way session Enter section 802 and then enter 30 thru 37 Toggle on every zones you want to initiate two way audio 6 Program the Miscellaneous Control Options for miscellaneous events Optional in programming section 802 and enter subsection 38 Toggle on any other event you want to initiate audio such as duress alarms or an opening after alarms event 7 Program the Microphone input assignment for zones 1 thru 64 in programming section 802 and enter subsection 40 thru 47 Enter for each zone which 1 4 is closest to that zone This will allow the central station operator to always speak to the speaker during a two way session 8 Program the Audio Options Optional in programming section 802 and select subsection 10 option 5 if you want the PC5950 to detect the central station has dropped the two way audio This will allow the central station to call the premise within 5 minutes after the alarm to start two way audio session option 6 to allow the end user to call the premise anytime to perform a two way session regardless an alarm has occurred Refer to the PC5950 user manual for detailed instructions for this procedure Tips Ensure the panel is seizing the telephone line during the alarm communication and two way Ensure the siren is turning off during the alarm when the two way session is in progress you are using SIA FSK format to transmit alarms the monitoring station should receive a L90 code after all the zone alarms transmit their reporting codes This means the panel is the central station to In for 90 seconds Test Procedure the system in the away mode and generate an alarm The siren should sound then turn off when the way session starts You will hear the central station operator switch between and Listen by beeps will be able to talk and listen to the operator Page 50

Related Files