DSC PG9926-PG8926-PG4926 - Smoke Detector - Installation Manual - Eng - S-CHI - R001
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pg9926-pg8926-pg4926-smoke-detector-installation-manual-eng-s-chi-r001-7413509826.pdf |
---|---|
Type | |
Size | 1.94 MB |
Downloads |
Text Preview
PG9926 PG8926 PG4926 Wireless PowerG Detector Installation smoke detectors provide open area protection and warning of developing fires by Activating a fire alarm upon a smoke condition Sounding an alarm with its built in alarm horn Transmitting a coded alarm signal to a compatible wireless control panel switch contacts Test Mute switch functions during normal operation as a switch and during an alarm condition as a Mute switch the Test Mute switch during an alarm condition stops buzzer sound for 8 minutes If the condition is not restored 8 minutes the buzzer will resound Pressing the mute will not restore the alarm condition tamper switch actuator is depressed when the unit is to the mounting bracket Removal of the unit from the bracket causes open a tamper event to the alarm system control panel detector is disabled when not attached to the mounting Setup The detector battery cover is fitted with a red button prevents the detector from locking onto the mounting if there is no battery inside The smoke detector is with a 3V CR123A battery To be installed by service persons in non hazardous only Risk of explosion if battery is replaced by an type Dispose of used batteries according to the instructions and according to local rules and Batteries are to be replaced by service persons Never remove batteries to stop a false alarm a window or fan the air around the detector to get rid of smoke The alarm will turn itself off when the smoke is If false alarms persist attempt to clean the detector as in this manual Do not stand close to the detector when the alarm sounding The alarm is loud in order to wake you in an Too much exposure to the horn at close range may harmful to your hearing To keep the smoke detector in good working order you test it weekly To ensure the continued operation of all wireless devices performing a system default a global upload of all programming via DLS is recommended before the system After completing the system default the wireless programming Buzzer Holes Test button and LEDs Bracket Detector 3 volt CR123A lithium consumer grade Battery terminals with insulator Battery cover Enroll button Tamper switch When the battery first contact the alarm horn sound for 1 beep Hold the bracket with one Rotate the detector counter and pull it from bracket Connection and Initial Test Open detector Open battery cover Connect battery to terminals verify correct polarity Close the battery and place the on the bracket Press the test button about 2 seconds When manually wireless if a device has powered up for than 48 hours it cannot be enrolled into the system until device has been tampered and restored When programming panel using the Quick Enroll procedure follow the steps in Enroll the Device into the System After restoring a low battery trouble the system may take to 5 minutes to clear the trouble the Device into the System quick enroll On a keypad press 8 Installer Code 804 000 Press and hold the device enroll button until the LED lights and then release the enroll button while the LED is lit A confirmation message then appears on the keypad Press key to confirm ID Enter 3 digit zone Enter 3 digit zone type Enter 1 digit partition for all desired partitions and press If using a menu based configuration you can scroll to the partitions and press to toggle the partition On an LCD keypad enter the label by using word library pre enroll Remotely configure the unique ID number into the system more information see the HSM2HOST manual When on site press the device enroll button If the wireless device has been powered for more than 48 without being enrolled tamper and restore the device to it a placement test permanently mounting any wireless device temporarily the device and perform a Placement test Tamper the device by removing the cover Restore the tamper The device now enters Placement test for 15 minutes The red LED blinks once to identify that a signal is being to the receiver and then blinks three times to identify the strength The following table indicates the received strength Strength communication response LED blinks LED blinks LED blinks blinks Only GOOD or STRONG signal strengths are If you receive a POOR signal from the device re it and re test until a GOOD or STRONG signal is For UL ULC installations only STRONG signal levels acceptable After product in conjunction with the compatible receivers HS2LCDRF P 9 HS2ICNRF P 9 and PG9920 For detailed Placement instructions refer to the control Reference Guide to Install Smoke Detectors detectors should always be installed in USA in with Chapter 29 of NFPA 72 the National Fire Code 29.5.1.1 Where required by other governing codes or standards for a specific type of occupancy single and multiple station smoke alarms shall be as follows In all sleeping rooms and guest rooms Outside of each separate dwelling unit sleeping area within verify ft 6.4 m of any door to a sleeping room with the dis measured along a path of travel On every level of a dwelling unit including basements On every level of a residential board and care occupancy facility including basements and excluding crawl and unfinished attics In the living area s of a guest suite In the living area s of a residential board and care occu small facility When mounting on ceiling the closest edge of the detector be at least 4 1m from the wall When mounting on wall the closest edge of the detector must at least 4 1m and no more than 12 3m from the ceil When mounting on sloped gabled or peaked ceilings the distance of the furthest edge of the detector from peak must be no more than 3 ft 9m As required by the California State Fire Marshall warning fire detection is best achieved by the installation fire detection equipment in all rooms and areas of the as follows A smoke detector installed in each separate sleeping area in vicinity but outside the bedrooms and 2 Heat or smoke in the living rooms dining rooms bedrooms hallways attics furnace rooms closets utility and rooms basements and attached garages any wireless device is recommended to mount device temporarily and a placement test Mark and drill 2 holes in mounting surface Fas the bracket to the surface with 2 Align bracket tabs with the detector slots and rotate the as shown Pull the detector outward to verify that it securely attached A battery must be inserted into the detector before the can be mounted onto the bracket Unauthorized of the unit from the bracket will initiate a tamper alert enter the wireless configuration section enter 804 Zone Toggles Supervision Default Y supervision of the device and Visual Indications dual color LED buzzer and siren are used to signal various and trouble messages as shown below Indication LEDs alarm Flash every battery every sec every sec every sec every sec 30 sec sen trouble sensitiv alarm to clean 2 flashes Flashes 60 sec siren Detector Test every sec Indica or long beeps 4 sec beep 2 sec beep 30 sec beep 60 sec beep 30 sec short beeps 30 sec short tones 1.5 sec tamper alarm will mute for 3 minutes at first power on will revert to normal mode when the tamper switch is changed of 15 sec between buzzer beep and LED operation Replacement This product uses lithium batteries improper may result in a