DSC PG9994-PG8994-PG4994 - Installation Manual - ENG - FRE - SPA - POR - R002

File Preview
File Preview
Click below to download for free

Text Preview

PG9994 PG8994 PG4994 Wireless High security PIR Motion Mirror Detector Installation PGx994 is a PowerG wireless outdoor digital mirror PIR which uses eight PIR sensors each acting as a Quad to accurately and reliably determine whether an alarm justified Features benefits include Optimum performance even in poor weather conditions as snow rain dust wind and direct sunlight Tamper protection prevents opening and removal from wall Built in link quality indicators reduce installation time by the need for the installer to physically approach control panel Microprocessor controlled compensation Immunity to pets weighing up to 18 Kg 40lb Pet immunity feature has not been evaluated to UL 639 ULC S306 03 due to the feature not being addressed in standard Setup To comply with FCC IC RF exposure compliance the PIR detector should located at a distance of at least 20 from all persons during normal The antennas used for this must not be co located or in conjunction with any antenna or transmitter The PG Series wireless PIR detectors shall be installed used within an environment that the pollution degree max 2 and overvoltages category in NON HAZARDOUS LOCATIONS The equipment is to be installed only by qualified service persons To ensure the continued operation of all wireless devices performing a system default a global upload of all wire programming via DLS is recommended before defaulting system After completing the system default download the programming LED Enroll button Tamper switch Bracket release Horizontal view of coverage area Vertical view of coverage area Vertical angle For wall tamper Back tamper switch is required for UL commercial bur installations the battery is recommended to perform the first batteries insertion on a surface After battery insertion the LED will flash for 60 and then the detector will enter a 15 minute local diag mode When manually programming wireless devices if a has been powered up for more than 48 hours it cannot be into the system until the device has been tampered and When programming the panel using the Quick Enroll follow the steps detailed in Enroll the Device into the in conjunction with the compatible receivers HSM2HOST9 HS2ICNRF P 9 and PG9920 For detailed Placement instructions refer to the control Reference Guide the Device Notes The top cover should only be accessed by service personnel or manufacturer Do not obscure detector field of view with large objects Install in position that expected intruder motion is perpendicular to the zones detection triggered by conditions such as weather blowing leaves brush or related environmental conditions etc need to be when assessing the installation and application If trips are not tolerable it is recommended that the wire outdoor intrusion detection unit is enrolled in the system to zone that is defined as a trouble alarm circuit whether motion alarms are always enabled only enabled at night For UL ULC installations mode is to only be used to supplement the covering the detection area Options Hightraffic Shutdown Default 01 this feature helps conserve battery power the system is disarmed by configuring a reporting When motion is detected the device transmits an to the receiver and will not report any further until the timer expires Any motion detected the configured period will be reported once the expires No Delay causes the device to report an each time the detector is tripped Detector Dis while dis 15 second 5m delay 60m delay 30 second 10m delay 5 second 20m delay No Delay 1m delay Detection Sensitivity Default 02 the sensitivity range of PIR devices Low Sensi High Sensi UL Standard the bracket firmly on a stable wall or pillar The of the fixed bracket must be as parallel as to the surveyed ground surface Mark drilling point Drill Adjust the detector with three long screws the detector to the bracket with two short screws and vertical according to the ground surface vertical angle indicator for various height and distance is detailed in following table the refers to a flat surveyed Verify the vertical by walk test 8 ft 7 ft 5 ft Distance ft ft Operation Indications LED blinks LED on 0.2 sec LED blinks twice warm up 60 open close quad PIR detection in mode alarm LED on 2 sec enter the wireless configuration section enter 804 Zone Toggles Alarm LED Default Y the devices LED to activate when an alarm occurs Supervision Default Y supervision of the device 24Hr Night Default Y Risk of explosion if battery is replaced by an incor type Dispose of used batteries according to the manufac instructions and according to local rules and regulations are to be replaced by service persons only Mirror Max Coverage At least 12 m 40 ft 90 Technology 8 independent quad PIR detectors oper in true Quad configuration Immunity Up to 18 Kg 40 lb Power Two 3V CR123A Lithium batteries For UL installations use Gold Peak GP only Life for typical use minimum one year typical 3 not verified by UL ULC Battery Threshold 4.0 V Band MHz CE Listed PG4994 433MHz CE listed PG8994 868MHz FCC IC UL ULC listed PG9994 Protocol PowerG Alert Reported when a tamper event occurs and in any message until the tamper switch is restored type Wall mounting Height 1.5 3.0 m 5 10 ft Must be 8 feet for listed installations Adjustment 45 to 45 in 5 steps Adjustment 0 to 10 in 2.5 steps range 40 to 70 UL ULC only verified range 35 to 66 Humidity up to max 93 RH non condensing Light Immunity Above 25000 lux H x L x W 157 x 147 x 124 mm 6 3 16 x 5 13 16 x 4 with battery 600 g 21 oz White or gray RECEIVERS Band HSM2HOST4 HS2LCDRF P 4 HS2IC PG4920 Band HSM2HOST8 HS2LCDRF P 8 HS2IC Band HSM2HOST9 HS2LCDRF P 9 HS2IC PG9920 Only devices operating in band 912 919MHz are UL listed Notes models PG9994 PG9994P operating in the frequency 912 919MHz are UL ULC listed The PG9994 PG9994P been listed by UL for commercial and residential burglary and by ULC for residential burglary applications in with the requirements in the Standards UL 639 and for Intrusion Detection Units UL ULC installations use these device only in conjunction compatible DSC wireless receivers HSM2HOST9 HS2ICNRF P 9 and PG9920 After installa verify the product functionality in conjunction with the receiver used The PG4994 and PG8994 are compliant with the RTTE Directive 1999 5 EC of the European Parliament and of Council of 9 March 1999 The PG8994 is certified by Applica Test Certification to the following standards EN50131 2 2 GRADE 2 IV EN50131 6 Type C Applica Test andApplica Test and Certification has only the 868 MHz variant of this product According to EN 50131 1 2006 and this equipment can be applied in installed systems up to and including Grade 2 Environmental Class II UK The PG8994 is suitable for use in installed to conform to PD6662 2010 at Grade 2 and environmental class 2 The Power G peripheral devices have two way communication functionality additional benefits as described in the technical brochure This functionality not been tested to comply with the respective technical requirements and should be considered outside the scope of the product certification COMPLIANCE STATEMENT Changes or modifications to this unit not expressly approved by th

Related Files