DSC PK5590CL - Installation Manual - English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pk5590cl-installation-manual-english-8609157342.pdf |
---|---|
Type | |
Size | 710.92 KB |
Downloads |
Text Preview
PK5590CL Color Touchscreen Security Interface Guide Colour LCD Display Compatible on partition 1 of single partition PowerSeries control panels PK5590CL Touchscreen is a touch sensitive color LCD Interface This provides interactive operation for the User of PowerSeries alarm pan programmed for partition 1 1 Front View to the associated User Guide and Alarm Panel installation for additional information of the Box Touch Panel Display Qty 1 User Guide Qty 1 This Installation Guide Qty 1 2 Back View Tabs Keybus Connection Panel programming must be performed with a PowerSeries The PK5590CL is intended for User programming functions operations Installation Guide shall be used in conjunction with the PANEL Installation Manual to which this equipment is device is powered from a Limited Power supply The wiring cables used to connect the PK5590CL Touchscreen shall be with PVC TFE PTFE FEP neoprene or polyimide Voltage Range 9.5 24.0 VDC Consumption 320 mA max Temperature Range 14 85 RH non condensing max Select a mounting location in the drywall between two studs that there is at least 1.5 clearance from the outer edge of back box and the nearest stud Cut a hole in the drywall using the template provided Fig 3 Route the 4 conductor keybus wire out from the wall Use 22AWG wire only 9.5VDC min required for Touchscreen Connect the Programming Keypad PK5500 to the keybus and Panel as indicated see Programming Do NOT remove keypad when programming is completed Remove the front bezel from the PK5590CL Insert a small slotted between the cover and plastic backplate and gently apart exposing screws for the drywall tabs Enter cid 2 8 Installer Code 902 Quickly remove Programming and install the PK5590CL described in Step 7 This must done within 30 seconds Connect the four Keybus wires to the terminals on the back of the in the locations indicated Position the unit in the wall cut out and secure using the two screws and drywall tabs Replace the front bezel by snapping in place Verify Correct Operation Refer to the PK5590CL User Guide is not supported on this command output panel Key 1 is used for Output Command 1 Function Key 2 is used for Command Output 2 3 Mounting Hole Template 4 holes in the positions indicated a 3 8 9.5mm drill bit Hole Template 10 cm cut out is 1.5 inches 4 cm from nearest stud to enable operation of drywall fasteners Compliance Statement Changes or modifications not expressly approved by Digital Security Controls could void your authority use this equipment equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance the manufacturer instructions may cause interference to radio and television reception It has been type tested and to comply with the limits for Class B device in accordance with the specifications in Subpart of Part 15 of Rules which are designed to provide reasonable protection against such interference in any residential installation there is no guarantee that interference will not occur in a particular installation If this equipment does cause to television or radio reception which can be determined by turning the equipment off and on the user is to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional suggestions user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Problems This booklet is available from the U S Government Printing Office Washington D C 20402 004 000 00345 4 Class B digital apparatus complies with Canadian ICES 003 appareil num de la classe B est conforme la norme NMB 003 du Canada Warranty Security Controls warrants that for a period of 12 months from the date of purchase the product shall be free defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty Security Controls shall at its option repair or replace the defective equipment upon return of the equipment its repair depot This warranty applies only to defects in parts and workmanship and not to damage incurred in or handling or damage due to causes beyond the control of Digital Security Controls such as lightning voltage mechanical shock water damage or damage arising out of abuse alteration or improper applica of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warran whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Security Controls neither assumes responsibility for nor authorizes any other person purporting to act on its to modify or to change this warranty nor to assume for it any other warranty or liability concerning this prod no event shall Digital Security Controls be liable for any direct indirect or consequential damages loss of antici profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or or failure of this product Digital Security Controls recommends that the entire system be completely tested on a regular basis However frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this to fail to perform as expected Information Changes or modifications not expressly approved by Digital Security Controls could void the authority to operate this equipment 2007 Printed in Canada