DSC PK55XX-RFK55XX-433 - Installation Manual - English - French - Dutch - Italian
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-pk55xx-rfk55xx-433-installation-manual-english-french-dutch-italian-3027518694.pdf |
---|---|
Type | |
Size | 4.87 MB |
Downloads |
Text Preview
Installation Instructions Instructions d Installatiehandleiding Istruzioni per l Fran Nederlands Italiano Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used Ce manuel contient des informations sur les restrictions concernant le fonctionnement et l du produit et des informations sur les restrictions en ce qui concerne la responsabilit du fabricant La totalit du manuel doit lu attentivement Ce manuel doit utilis en conjonction avec le Manuel d du Panneau de contr Raadpleeg de installatiehandleiding van het systeem voor informatie over beperkingen m b t productgebruik en functie en informatie over de beperkingen m b t aansprakelijkheid van de fabrikant Deze instructies dienen te worden gebruikt in combinatie met de installatiehandleiding van het systeem van de centrale waarmee deze apparatuur gebruikt wordt Fare riferimento al manuale di installazione del sistema per avere informazioni sui limiti riguardanti l e il funzionamento del prodotto nonch sui limiti di responsabilit del produttore Le presenti istruzioni devono essere impiegate in combinazione con il manuale d del sistema della centrale di controllo con il quale si intende utilizzare l 9 0 0 7 2 6 6 R0 0 1 Rotate 90 engage Instructions cid 129 PC1565 PK55XX keypads can be used on security systems with to 64 zones These keypads are compatible with the following DSC systems RFK55XX keypads combine a wireless receiver with the respective keypad Temperature range 10 to 55 14 to 131 Tempera range for UL ULC 0 to 49 32 to 120 Humidity MAX 93 R H Plastic enclosure protection degree IP30 IK04 Voltage rating 12VDC nominal Connects to control panel via 4 wire Keybus 1 keypad zone input PGM output PK55XX Current draw 50mA standby 125mA maximum RFK55XX Current draw 75mA standby 135mA maximum Wall mount tamper 5 programmable function keys Ready Green LED Armed Red LED Trouble Yellow LED AC LED Low temperature sensor Frequency 433.92MHz RFK55XX 433 Only Up to 32 wireless zones RFK55XX Only Zone not to be programmed as Fire type or 24h type Power keypad package includes the following parts Power keypad mounting screws end of line resistors should mount the keypad where it is accessible to designated of entry and exit Once you have selected a dry and secure loca perform the following steps to mount the keypad Keypad Removing the keypad from the backplate for the first time inner door labels tamper switch Instructions Position the keypad as indicated insert screwdriver and rotate Insert the screwdriver into slot at an angle and push Removing the keypad from backplate once mounted Open door holding it 90 to the keypad as shown below Insert screwdriver into slot located under the door hinge and the screwdriver Repeat steps 1 and 2 for left side Insert the screwdriver into slot at an angle and push and Wire Keypad Out Rotate 90 Slot Out Repeat steps 1 and 2 for right side Out to snap Secure Keypad to wall using mounting holes Use all 4 screws provided mounting on a single gang box Place keypad into hooks on the backplate and swing down to engage Run wire through wiring slot or knockouts Connect Keybus and PGM Zone to keypad Place tamper switch into tamper hole on backplate Remove keypad from hooks Place keypad into backplate ensure the wire pushed back into the wall as much as possible Route the wire inside keypad ensuring high components are avoided Snap the front assem closed ensuring that there is no pressure to the keypad from the wire If any tension found between the front keypad assembly and wiring open the keypad reroute the wire and close again Repeat these until the keypad is closed properly Before wiring the unit ensure that all power AC transformer and is disconnected from the control panel Connect the four Keybus wires from the panel red black yellow and to the keypad terminals Refer to zone or output If programmed as an input you can a device such as a door contact to the terminal of the keypad eliminates the need to run wires back to the control panel for device To connect the zone run one wire from the device to the terminal and the other wire from the device to the B black For powered devices run the red wire to the R positive and the black wire to the B negative terminal When end of line supervision connect the zone according to one of configurations outlined in your system Installation Manual Option If the terminal is programmed as an output the output follows PGM programmed in Section 080 A small relay buzzer or DC operated device may be connected between the positive voltage and the terminal maximum load is 50mA 4 Power all wiring is complete and the equipment is secured to the build structure with at least two screws apply power to the control panel Connect the battery leads to the battery Connect the AC transformer more information on control panel power specifications see the panel Installation Manual the Keypad are several program options available for the These are described Programming the key is similar to programming rest of the system When are in the keypad pro sections the key will display which options turned on along the top of display To turn an option or off press the number corresponding to the option on the number The numbers of the options that are currently turned ON will be For example if options 1 and 4 are on the display will like this on the different keypad displays information on programming the rest of your security system refer to your system Installation Manual LCD Labels LCD programming is done per keypad If more than one LCD key is present on the system labels programmed at one keypad can broadcast to all other LCD keypads Perform the following procedure order to broadcast labels 1 Program one LCD keypad completely 2 Make sure all LCD keypads are connected to the Keybus 3 Enter keypad programming by pressing cid 2 8 Installer then enter section 998 at the keypad that was pro The keypad will now broadcast all the information pro to all the other LCD keypads on the system 4 When the keypad is finished press the key to exit Label broadcast from this keypad is only compatible with other and RFK5500 Keypads Programming Only keys for 2 seconds to enter language programming to the desired language and Press cid 2 to select If section 077 option 4 is OFF language programming only be performed while in installers programming the Keypad keypad will need to be assigned to a partition and slot if supervi or keypad zones are being used Keypad assignments and key option programming must be done at each keypad individually 1st digit of keypad assignment is used to determine partition 1 to 8 If partitioning is not used enter 1 For Global enter 0 LED and ICON keypads cannot be programmed as Global Keypads 2nd digit of keypad assignment is used to determine slo