Adding Addressable Zones Power432 PC1555 Power632 PC5100 2 wire Addressable Device Interface Module can be used to connect up to 32 devices Each addressable device uses a 2 wire connection for power and to with the control panel This simplifies wiring and permits fast and efficient Each addressable device requires a separate zone number addressable zones has six step process Connect the PC5100 to the KEYBUS Connect the addressable devices to the PC5100 Programming the zone definitions Programming the zone attributes Programming the zone assignments Programming the zone serial numbers Sections 001 004 101 132 202 205 801 01 32 Definitions Attributes Assignment Serial Number 1 Connect the PC5100 to the KEYBUS the four KEYBUS terminals of the PC5100 to the four KEYBUS terminals of the panel If the addressable module is not connected to the KEYBUS the addressable data be programmed 2 Connect the Addressable Devices each addressable device to the STR and STR on the PC5100 All devices can be t tapped or connected in a daisy chain Addressable fire devices should be isolated the burglary addressable devices using an addressable isolator AMX 400 AML 770 3 Program the Zone Definitions addressable zones will operate on the system the zones must be defined Zones 1 to 8 Definitions Zones 9 to 16 Definitions Zones 17 to 24 Definitions Zones 25 to 32 Definitions Do not define addressable zones as 07 08 or 09 If using addressable smoke use zone definitions of 87 or 88 4 Program the Zone Attributes panel must be told which zones are addressable Turn Option 8 ON for all addressable in Sections 101 to 132 5 Zone Assignment any zone will operate the zone must be enabled on the system To enable zones on the turn ON the correct toggle option in the corresponding section 202 Partition 1 zones 1 to 8 enable disable 203 Partition 1 zones 9 to 16 enable disable 204 Partition 1 zones 17 to 24 enable disable 205 Partition 1 zones 25 to 32 enable disable 6 Enroll Addressable Devices the SN number or Serial Number for each addressable detection device in Section 801 01 to 32 Addressable detectors must be connected before they are enrolled If a long tone heard after entering the serial number the detector is not connected properly or number has been entered incorrectly Tips When using zone expanders or wireless detectors make sure the addressable detectors not assigned a zone already used on a PC5108 or as wireless Addressable detectors cannot be downloaded The serial numbers must be entered using a system keypad A General System Trouble will occur if the Addressable Loop is shorted Test the addressable zones and verify they are displayed on the keypad

Related Files