DSC Power864 - Keypad zones 864 rev 005

File Preview
File Preview
Click below to download for free

File Data

Name dsc-power864-keypad-zones-864-rev-005-2519863470.pdf
Type PDF
Size 635.64 KB
Downloads

Text Preview

Programming Keypad Zones Power864 version keypad has a zone input terminal This zone input can be used as any zone on system from 1 through 64 If the keypad zone is assigned a zone number that is present on main panel it will replace the existing zone and the zone on the main panel will be disabled keypad zones is a four step process Assign the keypad to a slot number Program a definition for the zone Assign the zone to the keypad slot Assign the zone to the partition Sections 000 0 001 004 020 202 265 Assignment 1 to 64 Definitions Zone Assignment Assignment Zones 1 to 64 8 Installer Code 000 0 1 Keypad Assignment use keypad zones each keypad must be assigned to its own slot 1 to 8 To assign a keypad a specific slot perform the following a two digit number The first digit is the partition the keypad will be assigned to 0 for operation 1 through 8 for partition 1 to 8 respectively The second digit is the slot the will be assigned to 1 to 8 DO NOT assign more than one keypad to the same slot Installer Programming Keypad Assignment Section Partition and Slot Assignment Section LCD5500Z keypads are being used one keypad must be assigned to slot 8 for purposes 2 Keypad Zone Definition must be defined before they will operate Depending on the control panel being used 30 different zone definitions are available Enter Section 001 004 and the 2 digit number corresponding to the required zone definition for each zone 001 Zones 1 to 16 002 Zones 17 to 32 003 Zones 33 to 48 004 Zones 49 to 64 3 Keypad Zone Assignment Section is used to program which zone will be assigned to which keypad slot Program the zone number that will be assigned to the keypad in the corresponding slot Enter data if no keypad is assigned to the slot or if the zone input on the keypad will not be used example installation has three LCD keypads assigned to slot 1 2 and 8 at least one LCD must be to slot 8 for downloading purposes to be used as zones 6 7 and 8 respectively section 020 with the following data Keypad zones cannot be assigned zone numbers that are already assigned to a Slot 5 00 Slot 6 00 Slot 7 00 Slot 8 08 Slot 1 06 Slot 2 07 Slot 3 00 Slot 4 00 hardwire zone expander 4 Partition Zone Assignment will not function until they are enabled Ensure that all zones being used are enabled If the keypad zone is being assigned to Partition 2 8 ensure the partition is 202 Section 209 Partition 1 Zone Assignments Zones 1 to 64 210 Section 217 Partition 2 Zone Assignments Zones 1 to 64 218 Section 225 Partition 3 Zone Assignments Zones 1 to 64 226 Section 233 Partition 4 Zone Assignments Zones 1 to 64 234 Section 241 Partition 5 Zone Assignments Zones 1 to 64 242 Section 249 Partition 6 Zone Assignments Zones 1 to 64 250 Section 257 Partition 7 Zone Assignments Zones 1 to 64 258 Section 265 Partition 8 Zone Assignments Zones 1 to 64 in Section 201 Tips Keypad zones will use the same EOL resistor option as the panel normally closed or end of line resistors Keypad zones do not support double EOL resistors exception RF5501 433 v5.0 a powered detector is being connected to a keypad zone use RED and BLACK of the connection for power Keypad zones cannot be assigned zone numbers that are already assigned to a PC5108 zone expander A keypad zone will immediately go into alarm when the panel is armed if more than one is assigned to the same slot Test the keypad zone and ensure it is displayed on the keypad

Related Files