DSC PowerG 2-way Wireless Outdoor Magnetic Contact with Auxiliary Input - Quick Start Guide - R004
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-powerg-2-way-wireless-outdoor-magnetic-contact-with-auxiliary-input-quick-start-guide-r004-5768043192.pdf |
---|---|
Type | |
Size | 1.68 MB |
Downloads |
Text Preview
l When enrolling the device to a wireless panel with a that does not support the device ID it is as W D Contact with the ID 101 XXXX the device was not automatically enrolled press the button as seen in Figure 1 callout B Enrollment options UL only a strong signal strength is acceptable detailed diagnostics test instructions refer to the panel Installer Guide After this step reattach the battery cover LED light is off in normal conditions the device Mounting on a flat surface 0.1 in roller shutter assembly the magnet needs to be 25 mm to 35 mm 1.0 in to 1.4 in from the on the Y plane For all other installations a gap of 5 mm 0.2 in is needed When mounting on a slide door refer to Y When on a roller shutter refer to X When on a normal door refer to Z Range coverage directions magnet magnet 2 way Wireless outdoor contact with auxiliary input PGx312 is a two way wireless PowerG magnetic device The devicehas the following features Weatherproof water resistant outdoor transceiver and curved surface installation Battery pull tab for auto enrollment at extreme temperatures 40 to 40 to 151 and is IP66 certified temperatures to 66 to 151 Battery life of up to five years with typical use magnetic sensor Maximum magnetic gap of 44.5 mm 1.75 in on and 31.8 mm 1.25 in on metal Magnetic sensor toggle if the auxiliary input only is Separate transmissions from sensor and auxiliary that trigger the same RF transmitter and back tamper protection back tamper not in US Automatic periodic supervision at regular intervals PowerG two way FHSS TDMA technology Paintable using non metallic paint Recommended include KRYLON for Plastic RUST and DUPLI COLOR Fabric following upcoming smart capabilities are available selected systems Anti masking protection based on panel software Auxiliary hardwired input programmable as either open NO normally closed NC end of EOL or double end of line DEOL for use with device DEOL is based on panel version Supports temperature level reports according to panel software version the device Enter into the installer menu and select 02 ZONES Select ADD NEW DEVICES Begin the auto enrollment process by pulling the tab the batteries or entering the device ID Select the required zone number Configure the location zone type and chime Configure the detector the magnetic contact device is already enrolled the magnetic contact device parameters the Modify Devices option See Step 2 configure the device parameters select the Device option and refer to Configuring the Device enroll the device power on the device by pulling battery tab or insert the batteries Both methods the auto enrollment process Alternatively the ID 107 XXXX the number of the device on the label Description tab button switch equipment is designed to be installed by qualified only Place the deviceabove the door or on the fixed frame and the magnet on the of the door or window Do not place the more than 44.5 mm 1.75 in from the marked of the device monitor outdoor areas you can mount the PGx312 on curvedsurface such as a fence pole or similar Once the battery cover is removed a tamper message transmitted to the panel Subsequent removal of the prevents transmission of the TAMPER alert leaving the receiver in permanent To avoid this press the tamper switch when you the battery Wait about 1 minute after battery removal before the new batteries Risk of explosion if the battery is replaced by incorrect type Dispose of the used battery according the manufacturer instructions Some models have a back tamper switch device As long as the device is seated firmly bracket the switch lever presses against a break away bracket segment that is loosely to the bracket Be sure to fasten the break segment to the wall If the detector unit is forcibly the wall this segment breaks away from bracket causing the tamper switchto open diagnostics test local diagnostic test establishes the signal strength of a its current position duringthe installation perform this mandatory test complete the steps Separate the decorative cover from the device and the battery cover See Steps 1 to 3 of the PGx312 Press the tamper switch once and release it Open the door or window and verify that detection is by a red LED flash two seconds the LED flashes three times in one three colors to indicate the signal strength 1 LED reception response LED Strong LED flashes Good LED flashes communication Reliable reception must be assured poor signal strength is not acceptable If you poor signal from the detector relocate it and until a good or strong signal strength is received regions requiring UL compliant installation only a signal strength is permitted a flat head screwdriver into the slot provided push upward to remove the decorative cover Unscrew the lower screw from the device cover Separate the device from the bracket Mark and drill the required number of holes in the surface Screw in the bracket with the four screws provided Reattach the device to the bracket Mount the magnet base with the two supplied screws an adjacent surface and attach the magnet to the bracket Mounting on a curved surface with straps mount the device on a curved surface use straps not as seen in Figure3 Use holes A and D in Figure 4 for standard mounting holes B and C in Figure 4 for tamper protection Align the device and magnet according to the in Range Coverage Directions Deviceand bracket separation mounting protection protection mounting Description coverage directions 2 Range coverage directions surface mm in mm in mm in mm in mm in mm in mm in mm in up Metallic surface Open mm mm in in mm mm in in mm mm in in mm mm in in values stated above may vary by up to 10 installations the gaps cannot be less than 3.2 UL commercial installations the maximum to activate is 50.8 mm 2 in X up refers to the upper half of the Y plane X down to the bottom half of the device on the X plane When mounting the magnet perpendicular to the align the magnet with the face of the device as in the perpendicular magnet image the device parameters the control panel DEVICE SETTINGS menu and the configuration instructions for the PGx312 contact device as described in Table 3 3 Magneticdevice parameters Configuration instructions whether to enable or disable the sensor settings Enable default or Disabled 1 Define the external input according to the requirements settings default NO EOL or DEOL support is dependent on panel version whether to enable or disable the anti settings Disabled default or This feature is dependent on panel version the auxiliary input UL installations the device connected to the circuit must be located in the same room as transmitter UL installations connect to UL listed residential alarm accessories only ULC installations connect ULC listed products to the auxiliary wiring input An alarm message transmits once the loop is opened short circuited connect this device with another nearby device by input complete the following steps Remove the jacket at the end of the cable to expose wires within in pin side Perforate the silicon gasket with a 0.8 mm Pass each wire through an entry hole and out the Remove the insulation from the end of each wire Connect each wire to the relevant terminal Auxiliary Wiring Options