DSC PowerG Wireless 360° Ceiling-mount PIR Detector - Installation Manual

File Preview
File Preview
Click below to download for free

Text Preview

4 the desired Zone Number any device parameters that are required and test the detector See Walk testing for information testing the device In addition see the alarm systems manual that the device is enrolled on for other procedures that are required If the detector is already enrolled you can configure the parameters by programming the system see the alarm sys installation manual for more information about device para When enrolling the PGx862 detector to wireless panels with version 19.4 or lower the detector will be enrolled as detector ID 120 xxxx and labelled Sens in the panel tips the following as a guide for locating a suitable mounting location Only GOOD or STRONG signal strengths are accept If you receive a POOR signal from the device re locate it and until a GOOD or STRONG signal is received For UL ULC installations only STRONG signal levels are After installation verify the product functionality in con with the compatible control panels HSM2HOST9 HS2LCDRF HS2ICNRF P 9 PG9920 WS900 19 and WS900 29 For detailed Placement instructions refer to the control panel manual the coverage area by walking across the far end of the cov pattern in both directions The red LED lights each time your is detected followed by a steady LED signal strength indication the device Mark and drill two holes in the mounting surface If you install protection on the detector mark and drill one hole for the protection and one hole for one of the other available the bracket to the mounting surface with the two screws Align the bracket tabs with the detector slots and rotate the clockwise Verify that it is securely attached the detector to the bracket with the screw Battery Capacity 1450 mAh Life typical use 1 year For typical use security mode 5 years not veri by UL Battery Threshold 2.5 V Inability to connect with wireless network or wireless link no higher than 20 may significantly reduce the expected bat life Power Test immediately upon battery insertion and periodically after several hours power supply is type C in accordance with EN 50131 6 Docu Clause 6 Consumption average quiescent maximum 150 mA during transmission 3 General Guidelines Keep away from heat sources Do not expose to air drafts Do not install outdoors Avoid direct sunshine Do not install near high voltage electrical lines Do not install behind partitions Mount on a solid stable surface Do not partially or completely obscure the detector of view To comply with FCC and ISED Canada RF exposure com requirements the PIR detector should be located at a distance at least 20 cm from all persons during normal operation The anten used for this product must not be co located or operated in con with any other antenna or transmitter The PGx862 Wireless ceiling PIR presence security detector be installed and used within an environment that provides the pol degree max 2 and overvoltages category II in NON LOCATIONS The equipment is designed to be only by qualified service persons PGx862 shall be installed in accordance with the Standard for and Classification of Residential Burglar Alarm Systems 1641 testing permanently mounting any wireless device temporarily mount device and perform a walk test Perform a walk test of the cov area at least once a week to ensure that the detector is working inserting the battery or closing the device the detector will auto enter a stability period where the LED flashes RED for 90 Walk test the coverage area the LED lights red each time motion is detected followed by 3 LED blinks The color of the 3 blinks indicate the received signal strength In walk test mode of the LED Selection status the LED lights upon every detection After 15 minutes the detector automatically enters mode following table indicates the received signal strength Response Signal Strength LED blinks STRONG LED blinks GOOD LED blinks blinks communication 4 Fastening the bracket 5 Attaching the detector Tamper protection Bracket screw slots Isolation strip Bracket tabs Detector slots 6 Fastening the detector following table outlines the detection distance in relation to the height m ft m ft m ft m ft warm up 90 seconds m ft detection distance 3.1 m ft UL ULC verified detection only at 11 ft 3.35 m radius when is installed at 9 ft 2.75 m height For UL installations the maximum mounting height is 9 ft 2.75 m Operation Indications LED blinks LED on 0.2 seconds Tamper open close LED on 2 seconds and light display instructions on displaying the temperature of zones on the correct as measured by the PGx862 refer to the panel installation guide Type pyroelectric sensor operating in a dual separated configuration Data type lens of beams 72 coverage m 360 at the maximum installation height of 4 m 13.1 ft alarm 7 Beam distribution at 2.7 m 8.9 ft Overview PGx862 is a smart wireless ceiling PIR presence security detector mode that creates a 360 coverage area to detect the move of intruders in indoor areas detector has the following features detection mode active 15 minutes after installation Built in link quality indicators eliminate the need for the installer to approach the control panel and reduce installation time device supports temperature and light level reports to com alarm systems that support temperature and light sensors Tamper protection two way Frequency Hopping Spread Spectrum FHSS technology The Advanced True Motion Recognition algorithm patented dis between the true motion of an intruder and any other dis which may cause false alarms For UL installations the detector is for use with UL listed con units only Tamper protection sensor Pyro sensor Battery 1 Internal view or replacing the battery the battery is already installed pull the activation strip that protrudes the back of the detector To separate the detector from the bracket rotate the bracket and pull it from the the battery while observing Align the bracket tabs with the slots and rotate the detector to verify that it is securely 2 Removing the It is recommended to wait about 1 minute after battery before inserting the new battery Risk of explosion if battery is replaced by an incorrect type of used batteries according to the manufacturer s instructions according to local rules and regulations to the panel installation manual for the enrollment procedure general description of the procedure is provided in the following chart the installation manual for the alarm system that the is being enrolled on to ensure that the proper steps used the Device Enrollment option through the specified and select the appropriate option to add the new the device by either inserting the battery to power on device until the enrollment is detected or by entering the ID Wireless ceiling PIR presence security detector Installation Instructions Tyco Security Products Toronto Canada www dsc com Tech Support 1 800 387 3630 Supply Type C Battery Lithium battery type CR 123A For UL installations use and GP only 8 Beam distribution at 4 m 13.1 ft Period 2 seconds m to 4 m 6.6 ft to 13.1 ft and rest of world 433 434 MHz 868 869 MHz USA 912 919 Only devices in frequency band 915 MHz are UL ULC listed Protocol PowerG Signaling at 256 s intervals Alert when a tamper event occurs and in any subsequent mes until the tamper switch is restored Options Ceiling surface Immunity V m up to 1000 MHz 10 V m up to 2700 MHz Temperatures to 55 14 to 131 UL verified operation range 0 to 49 only Temperatures to 60 4 to 140 relative humidity of up to approximately 75 non con For 30 days per year the relative humidity may vary between and 95 non condensing UL

Related Files