DSC PowerSeries 9045 Installation Manual - Australia
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-powerseries-9045-installation-manual-australia-2964185703.pdf |
---|---|
Type | |
Size | 1.40 MB |
Downloads |
Text Preview
Self Contained Wireless Alarm System AUS Installation Guide This manual contains information on limitations regarding product use and function and on the limitations as to liability of the manufacturer The entire manual should be carefully of Contents Wiring 1 2 2 Telephone Line Wiring 3 Battery Pack 3 AC Wiring 3 Device Enrollment 4 Programming 6 Programming 9 programming with PC Link 9 Programming via telephone line 9 10 Arming 10 Arming 10 10 Commands 10 keys 12 Selection 12 Programming 13 to Program 13 Toggle Options 13 Decimal Hexadecimal Data 13 to Exit Installer Programming 13 Programming 13 Worksheets 14 Programming Worksheets 14 Worksheets 15 Descriptions 32 Troubleshooting 47 A Code Formats Contact ID SIA 49 B Format Options 51 C Approvals Information 53 INSTRUCTIONS FOR SERVICE PERSONNEL WHEN USING EQUIPMENT CONNECTED TO THE TELEPHONE NETWORK THERE ARE SAFETY INSTRUCTIONS THAT SHOULD ALWAYS BE FOLLOWED REFER TO THE SAFETY PROVIDED WITH THIS PRODUCT SAVE THEM FOR FUTURE REFERENCE THE END USER REGARDING THE SAFETY PRECAUTIONS THAT SHALL BE OBSERVED OPERATING THIS EQUIPMENT Installing The Equipment not use a sharp or metal object to open the packaging Ensure your package includes the following items Guide Manual including the Safety Instructions Read and save these Instructions all Warnings and Instructions specified within these Instruction and or on the equipment SCW904x Supply Direct Plug In Mounting Hardware A Suitable Location For The Alarm Controller the following list as a guide to find a suitable place for this equipment it near a telephone socket and a power outlet a place that is free from vibration and shocks the Alarm Controller on a flat stable surface and follow the Installation suggestions NOT locate this product where persons will walk on the secondary circuit cable s NOT use extension cords to PLUG IN the Power Supply of this equipment setting up the equipment near heaters air conditioners ventilators and or refrigerators NOT connect the Alarm Controller to electrical outlets on the same circuit as large appliances NOT select a place that exposes your alarm controller to direct sunlight excessive heat moisture vapors chemicals or dust NOT install this Equipment near water e g Bath Tub Wash Bowl Kitchen Laundry sink In a wet basement or near swimming pool etc NOT install this equipment and its accessories in areas where there is a risk of explosion NOT connect this Alarm Controller to electrical outlets controlled by wall switches or automatic timers avoid interference sources Precautions Required During Installation install this equipment and or telephone wiring during a lightning storm touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface that cables are positioned so that accidents can not occur Connected cables must not be subject to excessive mechanical strain only the power supply supplied with this equipment Use of unauthorized power supplies may cause damage AC socket outlet powering the equipment shall be located near the equipment and shall be easily accessible EQUIPMENT HAS NO MAINS ON OFF SWITCH THE PLUG OF THE DIRECT PLUG IN POWER IS INTENDED TO SERVE AS THE DISCONNECTING DEVICE IF THE EQUIPMENT MUST BE DISCONNECTED IT IS IMPERATIVE THAT ACCESS TO THE MAINS PLUG AND ASSOCI MAINS SOCKET OUTLET IS NEVER OBSTRUCTED 1 Installation Wiring Installation Guide provides the basic installation wiring and programming information for the PowerSeries Self Contained SCW Security System publication covers the following versions of the SCW Security System 1 Installation Wiring v1.0 SUMMARY Range 0 32 Max 93 RH Non Condensing Supply 16.5VAC 20VA Min 50 60Hz Draw from Transformer 400mA AC Max Output 12.0 12.5VDC 100mA Zones 32 I O 2 1 Keys 16 Codes 16 1 Master Code Buffer 128 Events Display 2 Rows x 16 Char Transformer Secondary 16.5 VAC 20 40VA Backup 7.2VDC 1500 mAH Backup I O Terminals can be configured as Zone Inputs or PGM Outputs When configured as PGMs outputs are 50mA equipment SCW Alarm System shall be installed and used an environment that provides the pollution degree max 2 over voltages category II NON HAZARDOUS LOCATIONS only The equipment is DIRECT PLUG IN connected and designed to be installed serviced and or repaired by service only service person is defined as a person having appropriate technical training and experience necessary to aware of hazards to which that person may be exposed in a task and of measures to minimize the risks to that or other persons There are no parts replaceable by the within this equipment power supply must be direct plug in fail safe with dou or reinforced insulation between primary and secondary In EU countries it must meet the applicable require of the Low Voltage Directive and protected as per the Standard Requirements In all other countries must be of an approved type acceptable to the local authori it is