PC1404 v1.1 Descriptions Programming Descriptions Programming Descriptions following is a description of the programming features and options available in the PC1404 control panel This manual shall be used in conjunction with the PC1404 Installation Guide part number 29008503 Keypad Function Programming Key Null Not Used Stay Arm key is not used and will perform no function when pressed the partition to which the keypad is assigned All stay away and night type zones will be bypassed Delay type zones will provide entry and exit delay The quick arm controls whether an access code must be entered after pressing this function key The delay will be silent if the panel is armed using this function key the partition to which the keypad is assigned All stay away and night type zones will be at the end of the exit delay Delay type zones will provide entry and exit delay The arm feature controls whether an access code must be entered after pressing this function The exit delay will be audible if the panel is armed using this function key this function key is pressed the user must enter a valid access code The partition will and remove entry delay from the partition when the exit delay expires The key can be again to enable the entry delay This function key always requires an access code entry it has been pressed the key will toggle the door chime feature on or off One solid beep means the feature been disabled three short beeps means it has been enabled this function key is pressed the system enters the 1 Zone Bypassing menu If the panel can be configured to require an additional access code entry before the sys enters zone bypassing this function key is pressed the system enters the 2 Trouble Display menu this function key is pressed the keypad prompts for an access code entry If the master or an access code with similar permissions is entered the system enters the 5 User Programming menu this function key is pressed the keypad prompts for an access code entry If the master or an access code with similar permissions is entered the system enters the 6 User menu function key provides the user with a simple method of activating a PGM output pro as Command Output 1 By default an access code must be entered after the key is before the output will activate but this can be changed by disabling PGM attribute 5 this key will cause the panel to deactivate any output programmed as Sensor Reset this key will cause the panel to activate the Quick Exit feature function key provides the user with a simple method of adding stay away zones into the and it changes the stay armed mode to away armed mode function key provides the user with a simple method of activating PGMs programmed as Output 3 An access code may be required after pressing this key if PGM attribute is enabled system arms with all Night Zones bypassed even if the delay zones are violated during delay This key only works while the system is disarmed or armed in the stay mode The logs Armed in Night Mode for this closing type If no night zone types are programmed the system the panel will arm in away mode with an audible exit delay Normally no beeps are sounded and the exit delay is silent if this function key is used to quick arming toggle option controls whether an access code must be entered after the key is pressed function key provides the user with a simple method of activating a PGM output pro as Command Output 4 Away Arm 9 No Entry Arming 4 Door Chime On Off Not Used Zone Bypassing Trouble Display Not Used User Code Programming User Functions 7 1 Command Output 7 2 Smoke Detector Reset Not Used 0 Quick Exit 1 Reactivate Stay Away Not Used 7 3 Command Output 3 Night Arming 7 4 Command Output 4 Not Used Instant Stay Arming feature operates similarly to the stay arming function key except for the following this function key is pressed no acknowledgement beeps are sounded there is no exit and the system arms immediately The panel logs Armed in Stay Mode for this clos type If no stay away zone types are programmed the system arms in Away mode with no delay This function key must not be used in CP 01 listed systems Used Not Used Programming 1 8 are enabled by default Disable unused zones or enable additional zones in Section 001 Zone 1 Definitions The zone describe how each of the zones you use will operate Program a two digit code describing the zone definition Select a defi from the list below addition each zone has 16 different attributes which may be programmed in Sections 101 108 Zone Attributes See also pro descriptions Section 101 108 Zone Attributes Zone Definitions Null Zone zone type should be programmed if an input is not going to be used Programming this zone type should clear any trouble condi present on the zone input An EOL resistor is not required for this zone definition Delay 1 zone type normally used for entry exit doors can be violated and restored during the exit delay time without causing an alarm the exit delay has expired and the system is armed violating this zone shall start the entry delay 1 timer During the entry delay the keypad buzzer will sound steadily to advise the user that the system should be disarmed If the panel is disarmed before the time expires no alarm will be generated Delay 2 Zone zone type operates the similar to the delay 1 zone however it follows a different entry delay timer defined as Entry Delay 2 in 005 System Times Typically this zone type is used for garage doors or for entry exit points that require a different delay time what is being used for the main entry exit point The Delay 2 entry delay time can be set independently of Delay 1 in programming 005 System Times Instant Zone zone type causes an instant alarm if it is violated when the panel is armed it does not provide an entry delay when violated while This zone type does not generate an alarm when disarmed Typically this zone is used for windows patio doors or other perim zones and glass break detectors Interior Zone zones have an exit delay and an entry delay if a delay zone has been violated first The zone goes into alarm when the entry of the delay type zone has expired if the system has not been disarmed If the zone is violated without an entry or exit delay being on the system an immediate alarm is generated This zone will not cause an alarm if violated during the entry delay If the zone violated before the entry delay has begun it will cause an instant alarm Typically this zone is used for interior protection devices as motion detectors Interior Stay Away Zone the system is stay armed this zone is bypassed If the system is armed in away or night mode the zone acts like an Interior Zone type 04 Delay Stay Away Zone the system is stay armed this zone is bypassed If the system is armed in away or night mode this zone acts like a Delay 1 type 01 Delayed 24 hr Fire Zone Do not wire Fire zones on keypad zone terminals if the DEOL supervision option is enabled for the panel Section 013 Option 2 zone type requires a SEOL resistor and it cannot be reconfigured using the NC EOL or DEOL options in the panel The alarm is short the restored state is 5k6 and an open condition will generate a zone tamper and fire trouble When this zone is violated alarm output will be immediately activated pre alert but the communicator will be delayed for 30 seconds If the alarm is acknowl by pressing any key during this delay or by tripping a keyswitch zone the alarm output and the communicator will be delayed an 90 seconds giving the user time to correct the problem If the zone is still violated after the 90 second delay the sequence repeat the user does not press a key during the 30 second pre alert the alarm output will latch and the panel will communicate the alarm to central station The alarm will sound until the Bell Cutoff time expires 005 System Times or until a code is entered If a second Fire type zone is violated or if the Fire keys are pressed during the delay period the panel will latch the alarm output will immediately communicate the alarm violated Fire zone will be displayed on all keypads and can be delayed at any keypad Typically this zone is used for latching smoke Programming Descriptions Standard 24 hr Fire Zone hardwired Do not wire Fire zones on keypad zone terminals if the DEOL supervision option is enabled for the panel Section 013 Option 2 zone type requires a SEOL resistor and it cannot be reconfigured using the NC EOL or DEOL options in the panel The alarm is short the restored state is 5k6 and an open condition will generate a zone tamper and

Related Files