DSC PS3085 - Installation Manual - English - Power Supply (3 0 Amp Supply)

File Preview
File Preview
Click below to download for free

Text Preview

TM Features 12VDC 3.0A regulated power supply Stand by battery AC Trouble output Low Battery output Battery Test output Automatic shutdown to prevent deep battery discharge Self resetting solid state over current protection devices eliminate need for replacement fuses Selectable battery charging rates 500mA or 2.0A Specifications Transformer required 16.5VAC 40 VA or 50VA 80VA or 120VA Output 1.5A maximum power supply and battery charge current 40VA or 50VA transformer 3.0A maximum power supply and battery charge current 80VA or 120VA transformer AC Trouble Low Battery and Battery Test Outputs 50mA maximum to ground through 100W Battery Charge Current 500mA or 2.0A Dimensions 145mm L 83mm W 56mm H over heat sinks L 3.3 W 2.2 H over heat sinks the Power Supply suggest that the PS3085 and the stand by battery be mounted a cabinet the DSC DLC 1 cabinet features mounting holes for the PS3085 From the back of the cabinet press circuit stand offs into the appropriate holes and mount the cabinet the cabinet in place secure the PS3085 to the stand offs Supply N S T A L L A T I O N I N S T R U C T I O N S ACT Terminal activates when there is an AC failure the LBT activates when there is a low battery condition Upon these terminals switch to ground at 50mA maximum outputs may be used to activate an indicating device as an LED or a relay used to activate devices requiring current panel monitors for low battery and loss of AC trouble When either trouble condition is detected the keypad indicate the trouble and the appropriate reporting codes if will be sent TEST Terminal activates during the automatic battery test battery test is performed every 5 seconds During the test the power is lowered and the TEST terminal is activated for 0.5 The TEST terminal may be used to activate an indicating such as an LED An RM 1 RM1C relay may also be to the TEST terminal to switch a load into the power during the battery test The test load should be of a sufficient to test the battery under the expected load PS3085 features a battery test The test occurs every 5 seconds a duration of 0.5s The test will be extended to approximately 25s the panel detects a low battery condition Charge Current the battery charge current using jumper max max 40VA or 50VA 80VA or 120VA 7Ah and larger to 7Ah Panels with a 10s battery test are not supported Rev 01 29002582 R002 Connection Diagram Battery Test Connection Combus Connection The RM1C board is required when the PS3085 is to repower the Combus This is necessary correct Combus power up WARRANTY Security Controls Ltd warrants that for a period of twelve 12 months from the date of purchase by the original buyer the product shall be free defects in materials and workmanship under normal use and that fulfilment of any breach of such warranty Digital Security Controls Ltd shall at its repair or replace the defective equipment upon return of the equipment to its factory This warranty applies only to defects in parts and and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls Ltd such lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties whether expressed or implied of all other obligations or liabilities on the part of Digital Security Controls Ltd This warranty contains the entire warranty Digital Security Controls neither assumes nor authorizes any other person purporting to act on its behalf to modify or change this warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential damages loss of anticipated profits loss of time or any losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Digital Security Controls Ltd recommends that the entire system be tested on a regular basis However despite frequent testing due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected 1999 Digital Security Controls Ltd Flint Road Downsview Ontario Canada M3J 2J6 416 665 8460 Fax 416 665 7498 Tech line 800 387 3630 in Canada 29002582 R002

Related Files