DSC PTK5507 V1-1 INIS EN FR SP PO book

File Preview
File Preview
Click below to download for free

File Data

Name dsc-ptk5507-v1-1-inis-en-fr-sp-po-book-9716452803.pdf
Type PDF
Size 2.42 MB
Downloads

Text Preview

Installation Instructions Instructions d de instalaci de instala v1.1 Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used Ce manuel contient des informations sur les restrictions concernant le fonctionnement et l du produit et des informations sur les restrictions en ce qui concerne la du fabricant La totalit du manuel doit lu attentivement Ce manuel doit utlis en conjunction avec le Manuel d du Panneau de contr Consulte el Manual de instalaci del sistema para obtener informaci sobre las limitaciones del uso y funciones del producto asi como las limitaciones de la reponsabilidad del fabricante Estas instrucciones deber utilizarse conjuntamente con el Manual de instalaci del sistema del Panel de control con el que se vaya a utilizar este equipo Consulte o Manual de instala do sistema para obter informa acerca das limita relativas utiliza do produto e fun e informa acerca das limita relativas imputa responsabilidades ao fabricante Estas instru devem ser utilizadas em conjunto com o Manual de instala do sistema do painel de controlo com o qual este equipamento se destina a ser utilizado Instructions PTK5507 keypad can be used on security systems with up to 64 These keypads are compatible with the latest version of the Series V4.2 security systems Temperature range 0 to 49 32 to 120 Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 touchscreen Voltage rating 12VDC nominal Connects to control panel via 4 wire Keybus Keybus distance 60 m 200 ft max keybus distance in extra mode 33.5 m 110 ft Up to 8 keypads per system PTK5507 current draw 100 mA standby screen off 200 mA or alarm regular power mode 300 mA activated or Extra Power Mode Wall mount tamper 5 programmable function keys Ready Green LED Armed Red LED Trouble Yellow LED AC LED Touchscreen display 8.5 x 5.1 x 0.8 127.9 mm L x 195 W x 20.35 mm D SD card slot holds any standard Secure Digital SD card 32 x x 2.1 mm containing photos necessary the SD card can be formatted to file system FAT16 32 using a PC The maximum size SD card supported is 32GB Wiring standard four wire connection Viewing angle horizontal viewing angle 70 typ Vertical viewing angle 70 top 50 bottom typ Brightness 280 cd m2 Power keypad package includes the following parts One Power keypad Five mounting screws Five anchors for wall mounting screws 1 tamper switch required for UL commercial burglary listed 2 Mounting the backplate Installation Instructions User Manual should mount the keypad where it is accessible to designated of entry and exit Once you have selected a dry and secure perform the following steps to mount the keypad and Wire Keypad Remove the SD card before opening the touchscreen see 1 Disassembling the touchscreen removing the SD card will damage unit Remove screw at the bottom of the keypad Insert screwdriver into slots and pry up to remove cover 1 Removing the backplate hole hole slot for hole hole Run wire through wiring slot Connect keybus wiring to see Wiring section Place keypad into backplate ensuring the wire is pushed into the wall as much as possible Route the wire the keypad ensuring high components are avoided the front assembly closed ensuring that there is no to the keypad from the wire below If any tension is found between the keypad assembly and wiring please the keypad re route the wire and close Repeat these steps until the keypad is properly Before wiring the unit ensure that all power AC telecommunication network and battery is from the control panel Connect the four Keybus wires from the control panel yellow black and red to the keypad terminals to Figure 3 3 Wiring USED card Secure keypad backplate to wall using mounting holes Figure 2 Use all 4 screws provided unless mounting a single gang box Use the plastic anchors supplied if the is to be mounted on drywall If using the keypad secure the tamper plate to the wall with a screw Characters Backlight Brightness Level Press Options Keypad Config then Backlight Use slide bar to adjust brightness to desired setting Press the Back or Home button the Buzzer Level Press Options Keypad Config then Buzzer Control Use slide bar to adjust buzzer to desired setting Press the Back or Home button Calibration Mode Press Options Keypad Config then Calibration Press the cross hairs on the screen to complete calibration Calibration mode can also be entered pressing and holding the home button for seconds the Background Image Press Options Installer Menu Installer Code Keypad then Background Image Select image to use image from SD card as background To exit press Back or Home button Power all wiring is complete and the equipment is secured to the structure with at least two screws apply power to the control Connect the battery leads to the battery Connect the AC transformer Connect telecommunication network e g telephone line cable etc similar keypad Option 4 more information on control panel power specifications see the panel Installation Manual Route all the wiring according to local codes and regulations the Keypad are several available keypad below Programming the rest of the system When you are in the keypad sections the keypad will display which options are on To turn an option on or off press the number to the option on the number pad The numbers of the that are currently turned ON will be displayed For example options 1 and 4 are on the display will look like the diagram information on programming the rest of your security system refer to your system Installation Manual Do not enable keypad blanking panel section 016 option 3 If key blanking is enabled the panel will stop out the status and the keypad sta will be inaccurate the Keypad keypad will need to be assigned to a partition and slot if or keypad zones are being used Keypad assignments keypad option programming must be done at each keypad 1st digit of keypad assignment is used to determine partition 1 to 8 If partitioning is not used enter 1 2nd digit of keypad assignment is used to determine slot for keypad supervision Each keypad will be assigned a slot number from 1 to 8 the following at each keypad installed on the system Enter Installer Programming by pressing Options Installer Installer Code then Keypad Mode Prog Press 000 for keypad programming Press 0 for Partition and Slot Assignment Enter the 1st digit 1 to 8 for partition assignment Enter the 2nd digit 1 to 8 for slot assignment supervision Press the key twice to exit programming After assigning all keypads perform a supervisory reset by Options Installer Menu Installer Code 902 waiting for 60 seconds Press the key to exit programming after 60 seconds Labels Enter Options Installer Menu Installer Code then Label Select the desired Label to Program Using the keyboard on the screen enter the new label and save when complete LCD Labels LCD programming is done per keypad If more than one LCD is present on the system labels programmed at one keypad be broadcast to all other LCD keypads Perform the following

Related Files