DSC R2 FSB 210 Spec

File Preview
File Preview
Click below to download for free

File Data

Name dsc-r2-fsb-210-spec-1569783024.pdf
Type PDF
Size 1017.39 KB
Downloads

Text Preview

30000173 R2 FSB 210 Spec qxd 11 18 05 1 32 PM Page 1 Addressable Photoelectric Detectors Series addressable photoelectric smoke detectors series incorporate a low profile design and e a t u res that help reduce false alarms and pro v i d e smoke detection Designed for use with the A X S Y S PC4020CF commercial panel and control panels Power832 and Power864T M via PC5100 addressable zone expander the detectors automatic drift compensation self diagnostics and removable chambers Precise and quick testing easily accomplished with the test meter FSD 100 The detectors are UL listed for o m m e rcial and residential applications Features drift compensation removable smoke chamber sensitivity testing with test meter F S D 1 0 0 dual sensor heat detector option test from control panel MAXSYS terminals profile design mounting plate listed for commercial and applications R2 FSB 210 Spec qxd 11 18 05 1 32 PM Page 2 Addressable Photoelectric Detectors Series Alarm Reduction is committed to reducing false alarms and has integrated a of features into its addressable photoelectric smoke to provide reliable detection One important feature is drift compensation It provides a constant level of performance for long term false alarm free operation dust accumulates in the detector it compensates to maintain the factory set sensitivity and thereby minimizes the potential false alarms If the detector reaches its limit of compensation it indicate a trouble condition well before the sensitivity increases a level where false alarms will be generated Sensitivity Testing and quick sensitivity testing is easily accomplished with the handheld test meter F S D 1 0 0 Powered by a standard V alkaline battery and small enough to fit inside a shirt pocket the meter holds 500 readings that can be downloaded to any To initiate a reading a technician simply holds the test near a DSC smoke detector and activates the detector button Information Addressable Photoelectric Smoke Detector without Heat Sensor Addressable Photoelectric Smoke Detector with Heat Sensor Test Meter Handle Adapter for FSD 100 addressable photoelectric smoke detectors are with the MAXSYS PC4020CF commercial panel and PowerSeries control panels Power832 a n d via the PC5100 addressable zone expander 5.8 2.077 White Surface Twist non 1.8 SENSOR F C 32 to F 0 to C 5

Related Files